Plan Review Details - Permit 23040965
| Plan Review Stops For Permit 23040965 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-05-02 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-05-02 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-04-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-04-28 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-04-28 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2023-04-28 07:29:32 | | | | 1ST REVIEW FBC-2020 RES. GAS | | | PERMIT- 23040965 | | | 4/28/2023 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE GAS RISER IS INCOMPLETE BECAUSE IT DOESN???T | | | SHOW THE BRANCHES TO THE GENERATOR AND THE INTERIOR | | | APPLIANCES. PLEASE NOTE WHEN GAS PIPING SYSTEMS ARE | | | MODIFIED A COMPLETE RISER IS REQUIRED IN ORDER TO | | | VERIFY CORRECT SIZES ARE BEING MAINTAINED. WPB BUILDING | | | DEPT. RECORDS SHOW PERMIT 05081351 FOR GAS APPLIANCES, | | | 06100011 FOR GAS GENERATOR. PLEASE MODIFY THE RISER TO | | | INCLUDE THE FOLLOWING INFORMATION IN COMPLIANCE WITH | | | SEC. G2412.3 FBC RES. | | | | | | A) TOTAL BTU LOAD AND INDIVIDUAL BRANCH/APPLIANCE BTU | | | LOADS. | | | B) TYPES AND SIZES OF PIPING. | | | C) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER | | | TO THE MOST REMOTE APPLIANCE OUTLET. | | | D) BRANCH PIPE CONNECTION LOCATIONS. | | | E) LOCATIONS OF REGULATORS, SHUTOFF VALVES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-05-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-05-01 |
Time |
12:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-04-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-04-27 |
Time |
16:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-05-02 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-05-02 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2023-04-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-04-28 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-04-28 |
Time |
06:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-05-02 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-05-02 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-04-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-04-28 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-04-28 |
Time |
06:56 |
Sent To |
|
|
| Notes |
| 2023-04-28 07:31:50 | SIGNATURE REVIEW FBC- 2020 | | | PERMIT- 23040965 | | | 4/28/23 | | | | | | CODES IN EFFECT: | | | FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE GAS RISER SHALL BEAR THE PRINTED NAME AND | | | SIGNATURE OF THE FL. LICENSED CONTRACTOR OR QUALIFIER | | | WHO PREPARED THE DRAWING- SEC. 107.2.1 WPB. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | |
|
|
|