Plan Review Details - Permit 23040965
Plan Review Stops For Permit 23040965
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2023-05-02 Cont ID  
Sent By ccole Date 2023-05-02 Time 09:17 Rev Time 0.00
Received By ccole Date 2023-05-02 Time 09:07 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-04-28 Cont ID  
Sent By ccole Date 2023-04-28 Time 07:28 Rev Time 0.00
Received By ccole Date 2023-04-28 Time 06:56 Sent To  
Notes
2023-04-28 07:29:32 
 1ST REVIEW FBC-2020 RES. GAS
 PERMIT- 23040965
 4/28/2023
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE GAS RISER IS INCOMPLETE BECAUSE IT DOESN???T
 SHOW THE BRANCHES TO THE GENERATOR AND THE INTERIOR
 APPLIANCES. PLEASE NOTE WHEN GAS PIPING SYSTEMS ARE
 MODIFIED A COMPLETE RISER IS REQUIRED IN ORDER TO
 VERIFY CORRECT SIZES ARE BEING MAINTAINED. WPB BUILDING
 DEPT. RECORDS SHOW PERMIT 05081351 FOR GAS APPLIANCES,
 06100011 FOR GAS GENERATOR. PLEASE MODIFY THE RISER TO
 INCLUDE THE FOLLOWING INFORMATION IN COMPLIANCE WITH
 SEC. G2412.3 FBC RES.
  
 A) TOTAL BTU LOAD AND INDIVIDUAL BRANCH/APPLIANCE BTU
 LOADS.
 B) TYPES AND SIZES OF PIPING.
 C) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 D) BRANCH PIPE CONNECTION LOCATIONS.
 E) LOCATIONS OF REGULATORS, SHUTOFF VALVES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2023-05-02 Time   Rev Time 0.00
Received By amcgrego Date 2023-05-01 Time 12:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2023-04-28 Time   Rev Time 0.00
Received By amcgrego Date 2023-04-27 Time 16:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2023-05-02 Cont ID  
Sent By ccole Date 2023-05-02 Time 09:07 Rev Time 0.00
Received By ccole Date 2023-05-02 Time 09:07 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date 2023-04-28 Cont ID  
Sent By ccole Date 2023-04-28 Time 07:29 Rev Time 0.00
Received By ccole Date 2023-04-28 Time 06:56 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-05-02 Cont ID  
Sent By ccole Date 2023-05-02 Time 09:19 Rev Time 0.00
Received By ccole Date 2023-05-02 Time 09:07 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-04-28 Cont ID  
Sent By ccole Date 2023-04-28 Time 07:29 Rev Time 0.00
Received By ccole Date 2023-04-28 Time 06:56 Sent To  
Notes
2023-04-28 07:31:50SIGNATURE REVIEW FBC- 2020
 PERMIT- 23040965
 4/28/23
  
 CODES IN EFFECT:
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE GAS RISER SHALL BEAR THE PRINTED NAME AND
 SIGNATURE OF THE FL. LICENSED CONTRACTOR OR QUALIFIER
 WHO PREPARED THE DRAWING- SEC. 107.2.1 WPB.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved