Plan Review Details - Permit 23040920
Plan Review Stops For Permit 23040920
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 4 Status P Date 2023-06-08 Cont ID  
Sent By aoliver Date 2023-06-08 Time 07:43 Rev Time 0.00
Received By aoliver Date 2023-06-08 Time 07:43 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status F Date 2023-06-06 Cont ID  
Sent By aoliver Date 2023-06-06 Time 08:40 Rev Time 0.00
Received By aoliver Date 2023-06-06 Time 08:40 Sent To  
Notes
2023-06-06 08:40:38SEE PREVIOUS COMMENTS

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2023-05-31 Cont ID  
Sent By rmcphers Date 2023-05-31 Time 15:39 Rev Time 0.00
Received By rmcphers Date 2023-05-31 Time 15:39 Sent To  
Notes
2023-05-31 15:39:46PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-05-02 Cont ID  
Sent By lbond Date 2023-05-02 Time 15:49 Rev Time 0.00
Received By lbond Date 2023-05-02 Time 15:49 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-05-31 Cont ID  
Sent By rmcphers Date 2023-05-31 Time 15:38 Rev Time 0.00
Received By rmcphers Date 2023-05-31 Time 15:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-05-18 Cont ID  
Sent By rmcphers Date 2023-05-18 Time 09:45 Rev Time 0.00
Received By rmcphers Date 2023-05-18 Time 09:09 Sent To  
Notes
2023-05-18 09:42:24REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING G1.0 SHOWS THE INCORRECT BUILDING DATA -
 UNDER TYPE OF CONSTRUCTION YOU SHOW - UNSPRINKLERED -
 UNLIMITED AREA - CANNOT HAVE UNLIMITED AREA AND NO
 SPRINKLERS PER FBC 507.3
  
 2) PLEASE SHOW THE ADJACENT OCCUPANCY TYPE AND ANY
 REQUIRED FIRE SEPARATION BETWEEN YOU THE ADJACENT
 TENNANT - FBC 508.4
  
 3) PLEASE SHOW THE FIRE RATING OF THE STAIR ENCLOSURE
 1011.7.3 ENCLOSURES UNDER INTERIOR STAIRWAYS.
 THE WALLS AND SOFFITS WITHIN ENCLOSED USABLE SPACES
 UNDER ENCLOSED AND UNENCLOSED STAIRWAYS SHALL BE
 PROTECTED BY 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION
 OR THE FIRE-RESISTANCE RATING OF THE STAIRWAY
 ENCLOSURE, WHICHEVER IS GREATER. ACCESS TO THE ENCLOSED
 SPACE SHALL NOT BE DIRECTLY FROM WITHIN THE STAIRWAY
 ENCLOSURE.
  
 4) ACCESSIBLE RESTROOM - ON DRAWING A3.0 - PLEASE SHOW
 THE TOILET PAPER HOLDER DIMENSION FROM THE FRONT OF THE
 TOILET TO THE CENTER OF THE DISPENSER (NOT TO THE SIDE
 AS SHOWN)- FBC A 604.7 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER.
  
 5) ACCESSIBLE RESTROOM - ON DRAWING A3.0 - PLEASE SHOW
 THE TOILET REAR GRAB BAR LOCATION DIMENSIONS FROM THE
 CENTER OF THE TOILET (NOT FROM THE SIDE WALL AS SHOWN)
 PER FBC A 604.5.2 REAR WALL.
 THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24
 INCHES (610 MM) MINIMUM ON THE OTHER SIDE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-05-18 Cont ID  
Sent By mpeterso Date 2023-05-18 Time 14:08 Rev Time 0.00
Received By mpeterso Date 2023-05-18 Time 12:55 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-05-31 Cont ID  
Sent By pleduc Date 2023-05-31 Time   Rev Time 0.00
Received By pleduc Date 2023-05-31 Time 16:09 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-04-19 Cont ID  
Sent By pleduc Date 2023-04-19 Time   Rev Time 0.00
Received By pleduc Date 2023-04-19 Time 10:53 Sent To  
Notes
2023-04-19 10:57:58THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS AN INDICATION OF THE G 1.0 PLAN SHEET OF NO
 FIRE SPRINKLER SYSTEM; HOWEVER, THERE IS AN INDICATION
 OF A POST INDICATOR VALVE RIGHT OUTSIDE THE REAR OF THE
 UNIT.
  
 THIS VALVE WOULD INDICATE THE PRESENCE OF A FIRE
 SPRINKLER SYSTEM.
  
 PER NFPA 1
  
 1.7.12 PLANS AND SPECIFICATIONS.
  
 1.7.12.1 THE AHJ SHALL HAVE THE AUTHORITY TO REQUIRE
 PLANS AND SPECIFICATIONS TO ENSURE COMPLIANCE WITH
 APPLICABLE CODES AND STANDARDS.
  
 1.7.12.6 PLANS SHALL BE SUBMITTED TO THE AHJ PRIOR TO
 THE ALTERATION OF THE MEANS OF EGRESS OR FIRE
 PROTECTION SYSTEMS OF ANY EXISTING BUILDING.
  
 PLEASE REVIEW AND CONFIMR THE PRESENCE OF FIRE
 SPRINKLER PROTECTION.
  
 IF PRESENT, THE FIRE SPRINKLER & FIRE ALARM SYSTEMS
 SHALL BE MAINTAINED THROUGHOUT DEMO & CONSTRUCTION
 PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PROVIDE AN APPLICABLE NOTE OF THE LIFE SAFETY PLAN.
  
  
 2) THERE IS AN INDICATION OF THE G 1.0 PLAN SHEET OF A
 FIRE ALARM SYSTEM, BUT NO INDICATION OF FA WORK BEING
 COMPLETED.
  
 PER NFPA 1
  
 1.7.12 PLANS AND SPECIFICATIONS.
  
 1.7.12.1 THE AHJ SHALL HAVE THE AUTHORITY TO REQUIRE
 PLANS AND SPECIFICATIONS TO ENSURE COMPLIANCE WITH
 APPLICABLE CODES AND STANDARDS.
  
 THE FIRE ALARM SYSTEMS SHALL BE MAINTAINED THROUGHOUT
 DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE ALARM, INCLUDING DEMO, SHALL BE
 DONE UNDER SEPARATE PERMITS & SHOP DRAWINGS.
  
 PROVIDE AN APPLICABLE NOTE OF THE LIFE SAFETY PLAN AND
 ELECTRICAL PLAN
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-06-08 Cont ID  
Sent By aoliver Date 2023-06-08 Time 07:43 Rev Time 0.00
Received By aoliver Date 2023-06-07 Time 09:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-06-06 Cont ID  
Sent By aoliver Date 2023-06-06 Time 08:40 Rev Time 0.00
Received By aoliver Date 2023-06-02 Time 08:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-06-01 Cont ID  
Sent By aoliver Date 2023-06-01 Time 07:56 Rev Time 0.00
Received By aoliver Date 2023-05-30 Time 08:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-05-25 Cont ID  
Sent By hmoser Date 2023-05-25 Time 16:32 Rev Time 0.00
Received By hmoser Date 2023-04-18 Time 11:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-05-25 Cont ID  
Sent By hmoser Date 2023-05-25 Time 16:24 Rev Time 0.00
Received By hmoser Date 2023-05-25 Time 15:21 Sent To  
Notes
2023-05-25 16:24:45PASS PROVISO
 REFER TO SECTION C403.2.4.3 SHUTOFF DAMPERS
 2020 FLORIDA ENERGY CODE.

Review Stop P PLUMBING
Rev No 1 Status P Date 2023-05-08 Cont ID  
Sent By rwbrown Date 2023-05-08 Time 13:43 Rev Time 0.00
Received By rwbrown Date 2023-05-08 Time 13:43 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-05-31 Cont ID  
Sent By rmcphers Date 2023-05-31 Time 15:38 Rev Time 0.00
Received By rmcphers Date 2023-05-31 Time 15:38 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-05-02 Cont ID  
Sent By lbond Date 2023-05-02 Time 16:09 Rev Time 0.00
Received By lbond Date 2023-05-02 Time 16:09 Sent To  
Notes
***NONE***