| Plan Review Stops For Permit 23040920 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
4 |
Status |
P |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-06-08 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-06-08 |
Time |
07:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
F |
Date |
2023-06-06 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-06-06 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-06-06 |
Time |
08:40 |
Sent To |
|
|
| Notes |
| 2023-06-06 08:40:38 | SEE PREVIOUS COMMENTS |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2023-05-31 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-31 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-31 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2023-05-31 15:39:46 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | | RENOVATION.HTML | | | |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-02 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-02 |
Time |
15:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-05-31 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-31 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-31 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-05-18 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-18 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-18 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2023-05-18 09:42:24 | REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) DRAWING G1.0 SHOWS THE INCORRECT BUILDING DATA - | | | UNDER TYPE OF CONSTRUCTION YOU SHOW - UNSPRINKLERED - | | | UNLIMITED AREA - CANNOT HAVE UNLIMITED AREA AND NO | | | SPRINKLERS PER FBC 507.3 | | | | | | 2) PLEASE SHOW THE ADJACENT OCCUPANCY TYPE AND ANY | | | REQUIRED FIRE SEPARATION BETWEEN YOU THE ADJACENT | | | TENNANT - FBC 508.4 | | | | | | 3) PLEASE SHOW THE FIRE RATING OF THE STAIR ENCLOSURE | | | 1011.7.3 ENCLOSURES UNDER INTERIOR STAIRWAYS. | | | THE WALLS AND SOFFITS WITHIN ENCLOSED USABLE SPACES | | | UNDER ENCLOSED AND UNENCLOSED STAIRWAYS SHALL BE | | | PROTECTED BY 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION | | | OR THE FIRE-RESISTANCE RATING OF THE STAIRWAY | | | ENCLOSURE, WHICHEVER IS GREATER. ACCESS TO THE ENCLOSED | | | SPACE SHALL NOT BE DIRECTLY FROM WITHIN THE STAIRWAY | | | ENCLOSURE. | | | | | | 4) ACCESSIBLE RESTROOM - ON DRAWING A3.0 - PLEASE SHOW | | | THE TOILET PAPER HOLDER DIMENSION FROM THE FRONT OF THE | | | TOILET TO THE CENTER OF THE DISPENSER (NOT TO THE SIDE | | | AS SHOWN)- FBC A 604.7 DISPENSERS. | | | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 | | | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO | | | THE CENTERLINE OF THE DISPENSER. | | | | | | 5) ACCESSIBLE RESTROOM - ON DRAWING A3.0 - PLEASE SHOW | | | THE TOILET REAR GRAB BAR LOCATION DIMENSIONS FROM THE | | | CENTER OF THE TOILET (NOT FROM THE SIDE WALL AS SHOWN) | | | PER FBC A 604.5.2 REAR WALL. | | | THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG | | | MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER | | | CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24 | | | INCHES (610 MM) MINIMUM ON THE OTHER SIDE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-05-18 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-05-18 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-05-18 |
Time |
12:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-05-31 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-05-31 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-05-31 |
Time |
16:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2023-04-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-04-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-04-19 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2023-04-19 10:57:58 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS AN INDICATION OF THE G 1.0 PLAN SHEET OF NO | | | FIRE SPRINKLER SYSTEM; HOWEVER, THERE IS AN INDICATION | | | OF A POST INDICATOR VALVE RIGHT OUTSIDE THE REAR OF THE | | | UNIT. | | | | | | THIS VALVE WOULD INDICATE THE PRESENCE OF A FIRE | | | SPRINKLER SYSTEM. | | | | | | PER NFPA 1 | | | | | | 1.7.12 PLANS AND SPECIFICATIONS. | | | | | | 1.7.12.1 THE AHJ SHALL HAVE THE AUTHORITY TO REQUIRE | | | PLANS AND SPECIFICATIONS TO ENSURE COMPLIANCE WITH | | | APPLICABLE CODES AND STANDARDS. | | | | | | 1.7.12.6 PLANS SHALL BE SUBMITTED TO THE AHJ PRIOR TO | | | THE ALTERATION OF THE MEANS OF EGRESS OR FIRE | | | PROTECTION SYSTEMS OF ANY EXISTING BUILDING. | | | | | | PLEASE REVIEW AND CONFIMR THE PRESENCE OF FIRE | | | SPRINKLER PROTECTION. | | | | | | IF PRESENT, THE FIRE SPRINKLER & FIRE ALARM SYSTEMS | | | SHALL BE MAINTAINED THROUGHOUT DEMO & CONSTRUCTION | | | PERIODS | | | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | | DRAWINGS. | | | | | | PROVIDE AN APPLICABLE NOTE OF THE LIFE SAFETY PLAN. | | | | | | | | | 2) THERE IS AN INDICATION OF THE G 1.0 PLAN SHEET OF A | | | FIRE ALARM SYSTEM, BUT NO INDICATION OF FA WORK BEING | | | COMPLETED. | | | | | | PER NFPA 1 | | | | | | 1.7.12 PLANS AND SPECIFICATIONS. | | | | | | 1.7.12.1 THE AHJ SHALL HAVE THE AUTHORITY TO REQUIRE | | | PLANS AND SPECIFICATIONS TO ENSURE COMPLIANCE WITH | | | APPLICABLE CODES AND STANDARDS. | | | | | | THE FIRE ALARM SYSTEMS SHALL BE MAINTAINED THROUGHOUT | | | DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE ALARM, INCLUDING DEMO, SHALL BE | | | DONE UNDER SEPARATE PERMITS & SHOP DRAWINGS. | | | | | | PROVIDE AN APPLICABLE NOTE OF THE LIFE SAFETY PLAN AND | | | ELECTRICAL PLAN | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-06-08 |
Time |
07:43 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-06-07 |
Time |
09:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-06-06 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-06-06 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-06-02 |
Time |
08:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-06-01 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-06-01 |
Time |
07:56 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-05-30 |
Time |
08:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-25 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-04-18 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2023-05-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-25 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-25 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2023-05-25 16:24:45 | PASS PROVISO | | | REFER TO SECTION C403.2.4.3 SHUTOFF DAMPERS | | | 2020 FLORIDA ENERGY CODE. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-08 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-08 |
Time |
13:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-05-31 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-31 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-31 |
Time |
15:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-02 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-02 |
Time |
16:09 |
Sent To |
|
|
| Notes |
|
|