| Plan Review Stops For Permit 23040839 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2023-05-24 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-24 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-24 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2023-05-24 11:50:46 | RECEIVED EMAIL FROM CONTRACTOR. UPLOADED NEW SHEET AND | | | CHANGED TO PASS. | | 2023-05-24 11:07:04 | YOU NEED TO RESUBMIT THE DRAWING WITH THE RIGHT PIPE | | | SIZE ON THE 1ST LENGTH OF PIPINE (1 1/2") |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-22 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-22 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2023-05-22 07:38:50 | 1ST GAS REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. NOT ADDRESSED CORRECTLY - SEE NOTES BELOW -- 2020 | | | FRC G2413.3 (402.3) - THE LINE FROM THE METER TO THE | | | 1ST TEE APPEARS TO BE UNDERSIZED. ACCORDING TO TABLE | | | 402.4(22)-250 FT, YOU ARE UNDERSIZED. 1 1/4 CAN ONLY | | | HANDLE 2,040K BTU AND YOU ARE RUNNING 2,651K BTU. | | | | | | NOTES: YOU ARE STATING THAT THE LONGEST RUN IS 110'? | | | THE LONGEST RUN IS MEASURED FROM THE SUPPLY TO THE | | | FURTHEST FIXTURE. THIS WOULD BE 220'. THE NEXT LINE ON | | | THE GAS CHART IS 250'. ACCORDING TO THAT LINE IN THE | | | TABLE, YOU ARE UNDERSIZED. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-05-16 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-16 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-16 |
Time |
08:23 |
Sent To |
|
|
| Notes |
| 2023-05-16 09:55:48 | 1ST GAS REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2020 FRC G2413.3 (402.3) - THE LINE FROM THE METER | | | TO THE 1ST TEE APPEARS TO BE UNDERSIZED. ACCORDING TO | | | TABLE 402.4(22)-250 FT, YOU ARE UNDERSIZED. 1 1/4 CAN | | | ONLY HANDLE 2,040K BTU AND YOU ARE RUNNING 2,651K BTU. | | | | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-05-24 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-24 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-23 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-22 |
Time |
07:39 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-19 |
Time |
08:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-16 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-16 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-09 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2023-05-24 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-24 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-24 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-22 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-22 |
Time |
07:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-16 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-16 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-16 |
Time |
08:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
N |
Date |
2023-04-14 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-04-14 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-04-14 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2023-04-14 13:55:28 | APPROVED ON MASTER |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2023-05-16 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-05-16 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-05-16 |
Time |
08:23 |
Sent To |
|
|
| Notes |
|
|