| Plan Review Stops For Permit 23040367 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
3 |
Status |
P |
Date |
2023-07-03 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-03 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-03 |
Time |
15:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
F |
Date |
2023-06-09 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-06-09 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-06-09 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2023-06-09 10:30:18 | SEE PREVIOUS COMMENT |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2023-04-21 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-21 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-21 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2023-04-21 12:28:13 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 223040367 | | | | | | REVIEWED: 4.21.2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENT: | | | | | | ASBESTOS REVIEW: | | | | | | FAILED PLAN REVIEW: | | | | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | | -RENOVATION.HTML | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-07-03 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-03 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-03 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-06-09 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-06-09 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-06-09 |
Time |
10:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-04-21 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-21 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-21 |
Time |
12:32 |
Sent To |
|
|
| Notes |
| 2023-04-21 12:36:12 | COMPLY TO ALL TRADES COMMENTS, SIGNATURE AND ASBESTOS | | | REQUIREMENTS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2023-07-07 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-07-07 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-07-07 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-06-21 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-06-21 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-06-21 |
Time |
16:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-04-24 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-04-24 |
Time |
12:01 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-04-24 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2023-04-24 12:01:01 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. IN ORDER TO PROCEED WITH THE ELECTRICAL PLAN REVIEW | | | FOR PERMIT 23040367, YOU NEED A DEMOLITION PERMIT | | | APPLICATION FOR APPROVAL. | | | | | | 2. DETAIL ANY ELCTRICAL SCOPE OF WORK OR INDICATE THAT | | | THERE IS NOT ANY ELECTRICAL WORK. FBC 107.3.5.3 | | | | | | END OF COMMENTS | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | RUBEN PEREZ PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6738 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2023-06-30 |
|
|
Cont ID |
|
| Sent By |
clfranci |
Date |
2023-06-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
clfranci |
Date |
2023-06-30 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-06-09 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-06-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-06-09 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-04-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-04-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-04-13 |
Time |
12:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-07-17 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2023-07-17 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2023-07-17 |
Time |
12:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-06-26 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2023-06-26 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2023-06-26 |
Time |
12:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-04-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-04-25 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-04-12 |
Time |
13:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2023-07-17 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2023-07-17 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2023-07-17 |
Time |
12:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2023-06-26 |
|
|
Cont ID |
|
| Sent By |
cmontell |
Date |
2023-06-26 |
Time |
12:55 |
Rev Time |
0.00 |
| Received By |
cmontell |
Date |
2023-06-26 |
Time |
12:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-04-25 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-04-25 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-04-25 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2023-04-25 15:56:06 | PROVIDE THE REQUIRED VENTILATION FOR THIS BATHROOM. FMC | | | TABLE 403.3.1.1 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2023-06-30 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-06-30 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-06-30 |
Time |
07:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2023-06-09 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-06-09 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-06-09 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2023-06-09 10:51:44 | 2ND PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. ADDRESSED BY RESPONSE LETTER | | | | | | 2. ADDRESSED BY RESPONSE LETTER | | | | | | 3. ADDRESSED BY RESPONSE LETTER | | | | | | 4. THE ADDITION OF THE BATHROOMS AND THE WORK WITHIN | | | THOSE BATHROOMS SHALL COMPLY WITH THE FLORIDA PLUMBING | | | CODE. HOT WATER IS REQUIRED PER 607.1. PLEASE SHOW THE | | | REQUIRED HOT WATER AND THE MIXING VALVE REQUIRED. | | | 2020 FPC 607.1 - SHOW THE REQUIRED HOT WATER. ALSO | | | INCLUDE DETAILS THAT SHOW COMPLIANCE WITH 607.1.1/613.1 | | | AS WELL AS 607.1.2/419.5. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-04-19 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-04-19 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-04-19 |
Time |
10:31 |
Sent To |
|
|
| Notes |
| 2023-04-19 10:35:39 | 1ST PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2020 FPC 403.1.1 - PLEASE SHOW THE OCCUPANT LOAD AND | | | USE OF EACH SPACE TO SHOW COMPLIANCE WITH THE MINIMUM | | | NUMBER OF PLUMBING FIXTURES REQURIED FOR THE USE. | | | | | | 2. 2020 FPC 403.1.1 - SHOW THE OCCUPANT LOAD AND | | | DETERMINE IF YOU NEED TO PROVIDE A DRINKING FOUNTAIN OR | | | THE EXEMPTION FROM ONE. | | | | | | 3. 2020 FPC 403.1.1 - SHOW THE REQUIRED SERVICE SINK OR | | | THE THAT YOU QUALIFY FOR THE EXCEPTION. | | | | | | 4. 2020 FPC 607.1 - SHOW THE REQUIRED HOT WATER. ALSO | | | INCLUDE DETAILS THAT SHOW COMPLIANCE WITH 607.1.1/613.1 | | | AS WELL AS 607.1.2/419.5. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-07-03 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-03 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-03 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-06-09 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-06-09 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-06-09 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-04-21 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-21 |
Time |
12:26 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-21 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2023-04-21 12:27:10 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23040367 | | | | | | REVIEWED: 4.21.2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENTS: | | | | | | PLAN REVIEW RESULTS: DENIED | | | | | | 1) THE PLANS SHEETS FOR THE PROJECT ARE NOT DIGITALLY | | | SIGNED BY THE ARCHITECT OF RECORD AS REQUIRED BY FL. | | | STATUTE AND SEC.: 61G1-16.005 FLORIDA ADMINISTRATIVE | | | CODE. PLANS TRANSMITTED ELECTRONICALLY SHALL BEAR | | | DIGITAL SIGNATURES AND SEALS CAPABLE OF BEING VERIFIED. | | | THE PLANS SUBMITTED FOR REVIEW ARE COPIES OF A SIGNED | | | AND SEALED PAPER PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | |
|
|