| 2023-04-05 13:50:26 | RESIDENTIAL (R3) BUILDING REVIEW COMMENTS |
| | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. |
| | REVISION# 23031810 |
| | 201 SUMMA ST |
| | |
| | 1-PROVIDE PRODUCT APPROVAL FOR: |
| | |
| | (A)ROOF TILE HIP & RIDGE METAL SUPPORT. |
| | RESPONSE: |
| | ARCHITECT'S RESPONSE LETTER STATES " EAST COAST METALS |
| | RIDGE ADDED TO PRODUCT APPROVAL INDEX: FL5374-R6". |
| | PRODUCT APPROVAL WAS NOT SUBMITTED. NEED TO SUBMIT. |
| | |
| | (B)STRUCTURAL MULLIONS THAT MEETS DESIGN PRESSURES FOR |
| | WINDOW "J". |
| | RESPONSE: |
| | ARCHITECT'S RESPONSE LETTER STATES " MULLION |
| | HIGHLIGHTED PAGE 12 OF MULLION NOA". |
| | PAGE 9 OF 25 OF MULLION NOA SPECIFIES 1"X3.125"X.5" |
| | ALUMINUM TUBE MULLION. |
| | THIS MULLION SIZE DOESN'T MEET THE DESIGN PRESSURES |
| | CALCULATED BY THE ARCHITECT OF RECORD. REVISE MULLION |
| | SIZE AS REQUIRED. |
| | |
| | (C)EXTERIOR OUTSWING DOOR ON NEW UNDER STAIR STORAGE. |
| | RESPONSE: |
| | ARCHITECT'S RESPONSE LETTER STATES "REFER TO PRODUCT |
| | INDEX NOA 20-0406.03". |
| | THIS NOA 20-0406.03 IS FOR MULLIONS. REVISE AS REQUIRED |
| | AND PROVIDE PRODUCT APPROVAL. |
| | |
| | (D)EXTERIOR SOLID OUTSWING DOOR ON NEW PRIVACY WALL |
| | NEXT TO THE NEW STAIRWAY. |
| | RESPONSE: |
| | ARCHITECT'S RESPONSE LETTER STATES "THIS IS A GARDEN |
| | GATE. WILL BE ENGINEERED- SHOP DRAWING TO BE |
| | SUBMITTED." |
| | NOTE: OK. SUBMIT ENGINEERING REVIEWED BY ARCHITECT |
| | PRIOR TO INSTALLATION. |
| | |
| | (E)ENTRY DOOR WITH SIDELITES AS SHOWN ON PLANS. |
| | RESPONSE: |
| | ARCHITECT'S RESPONSE LETTER STATES "SEE PRODUCT INDEX." |
| | PRODUCT APPROVAL LISTED IN THE INDEX WAS NOT SUBMITTED. |
| | NEED TO SUBMIT. |
| | |
| | 2-DESIGNER OF RECORD TO APPROVE ABOVE PRODUCT |
| | APPROVALS. |
| | |
| | 3- REVISED ENERGY CALCULATIONS HAVE A COPY OF THE |
| | ENGINEER'S DIGITAL SIGNATURE. NEED ORIGINAL |
| | SEAL/SIGNATURE WHEN SUBMITTED FOR PUBLIC RECORDS. |
| | ELECTRONIC SUBMITTALS NEED VERIFIABLE DIGITAL |
| | SIGNATURE. |
| | |
| | ENGINEERS |
| | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND |
| | SEALING ELECTRONICALLY TRANSMITTED PLANS, |
| | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
| | |
| | |
| | NEW COMMENTS BASED ON REVISED ROOF PRODUCT APPROVALS |
| | |
| | 3- WINDSOR ROOF TILE NOA LISTED ON PRODUCT APPROVAL |
| | INDEX(21-0201.05) AND NOA SUBMITTED(22-0201.05)DON'T |
| | MATCH. REVISE AS REQUIRED TO MATCH. SEC. 107.2.1 CITY |
| | AMENDMENTS. |
| | |
| | 4- NEW ROOF TILE NOA SUBMITTED: CLEARLY IDENTIFY |
| | ADHESIVE PADDY SIZE TO BE USED AS REQUIRED BY CITY |
| | POLICY FOR ALL ROOFING PERMITS TO VERIFY COMPLIANCE |
| | WITH THE REQUIRED UPLIFT MOMENT FOR TILE. SEC R301.2.1 |
| | FBC-RESIDENTIAL. |
| | NOTE: COORDINATE WITH FOAM ADHESIVE COMMENT BELOW. |
| | |
| | 5- ROOF TILE ADHESIVE NOA SUBMITTED: CLEARLY IDENTIFY |
| | ADHESIVE PADDY SIZE TO BE USED AS REQUIRED BY CITY |
| | POLICY FOR ALL ROOFING PERMITS TO VERIFY THE REQUIRED |
| | UPLIFT MOMENT FOR TILE. SEC R301.2.1 FBC-RESIDENTIAL. |
| | NOTE: COORDINATE WITH ROOF TILE COMMENT ABOVE. |
| | |
| | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND |
| | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE |
| | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |
| | |
| | |