Plan Review Details - Permit 23031364
Plan Review Stops For Permit 23031364
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2023-05-31 Cont ID  
Sent By jwitmer Date 2023-05-31 Time 12:46 Rev Time 0.00
Received By jwitmer Date 2023-05-31 Time 12:31 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-03-29 Cont ID  
Sent By jwitmer Date 2023-03-29 Time 07:34 Rev Time 0.00
Received By jwitmer Date 2023-03-28 Time 16:48 Sent To  
Notes
2023-03-29 07:34:51COMMERCIAL ASBESTOS
 TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON THE CONTRACTOR???S LETTERHEAD, STATING
 THAT THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS
 PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM
 BEACH COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION
 WILL BE GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
 HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC
 ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION
 -RENOVATION.HTML
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-05-31 Cont ID  
Sent By jwitmer Date 2023-05-31 Time 12:52 Rev Time 0.00
Received By jwitmer Date 2023-05-31 Time 12:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-29 Cont ID  
Sent By jwitmer Date 2023-03-29 Time 07:31 Rev Time 0.00
Received By jwitmer Date 2023-03-28 Time 16:48 Sent To  
Notes
2023-03-29 07:31:12WEST PALM BEACH DEVELOPMENT SERVICES-
 BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 23031364
 ADD: 400 CLEMATIS ST. # 103
 CONT: R. C. COLE CONSTRUCTION
 TEL: 561-523-7245
 E-MAIL: BOBCOLE@RCCONSTRUCTIONINC
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. MARCH 29TH/2023
 ACTION: DENIED
  
 1) THE PERMIT APPLICATION VALUE IS LOW FOR THE AMOUNT
 OF WORK BEING COMPLETED UNDER THIS PERMIT.
 109.3 BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDERESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 2) SHEET A3.03 WALL AND CABINETRY DETAILS SHOW A NEW
 DINING COUNTER IN THE FRONT WINDOW MARKED C AND IS AT A
 HEIGHT OF 36 INCHES. THE PLANS DO NOT STATE THE AMOUNT
 OF SEATS AND TABLE SPACES THERE IS IN THE DINING ROOM
 PLEASE PROVIDE COMPLIANCE FOR THE
 FOLLOWINGACCESSIBILITY CODE REQUIREMENTS, THE SHEET
 A3.03 DOES NOT SHOW COMPLIANCE WITH THE 2020
 FBC-ACCESSIBILITY CODE.
  
 2A) 226.1 WHERE DINING SURFACES ARE PROVIDED FOR THE
 CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE
 SEATING SPACES AND STANDING SPACES AT THE DINING
 SURFACES SHALL COMPLY WITH 902.
  
 2B) 226.2 DISPERSION. DINING SURFACES AND WORK SURFACES
 REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED
 THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING
 SURFACES AND WORK SURFACES.
  
 2C) 206.2.5 206.2.5 RESTAURANTS AND CAFETERIAS. IN
 RESTAURANTS AND CAFETERIAS, AN ACCESSIBLE ROUTE SHALL
 BE PROVIDED TO ALL DINING AREAS, BARS, INCLUDING RAISED
 OR SUNKEN DINING AREAS, AND OUTDOOR DINING AREAS.
  
 2D) 902.1. DINING SURFACES AND WORK SURFACES SHALL
 COMPLY WITH 902.2 AND 902.3. ADVISORY 902.1 GENERAL.
 DINING SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS,
 TABLES, LUNCH COUNTERS, AND BOOTHS. EXAMPLES OF WORK
 SURFACES INCLUDE WRITING SURFACES, STUDY CARRELS,
 STUDENT LABORATORY STATIONS, BABY CHANGING AND OTHER
 TABLES OR FIXTURES FOR PERSONAL GROOMING, COUPON
 COUNTERS, AND WHERE COVERED BY THE ADA SCOPING
 PROVISIONS, EMPLOYEE WORKSTATIONS.
  
 2E)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR
 SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD
 APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
  
 2E)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND
 WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 3) SHEET A3.03 SHOWS BOTH COUNTER HEIGHTS COUNTER C AT
 36 INCHES IN HEITH AND COUNTER TYPE D AT 30 INCHES OF
 HEIGTH. AS STATED ABOVE IN COMMENT 2E)(2) ) 902.3
 HEIGHT. THE TOPS OF WORK SURFACES SHALL BE 28 INCHES
 MINIMUM AND 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR
 GROUND. PLEASE ALSO SHOW POINT OF SALE COUNTER ON THE
 FLOOR PLAN.
  
 4) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT
 REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE.
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-05-19 Cont ID  
Sent By rperdomo Date 2023-05-19 Time 15:35 Rev Time 0.00
Received By rperdomo Date 2023-05-19 Time 15:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-04-04 Cont ID  
Sent By rperdomo Date 2023-04-04 Time 16:35 Rev Time 0.00
Received By rperdomo Date 2023-04-04 Time 16:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-05-11 Cont ID  
Sent By pleduc Date 2023-05-11 Time   Rev Time 0.00
Received By pleduc Date 2023-05-11 Time 11:18 Sent To  
Notes
2023-05-11 11:19:28FIRE PREVENTION COMMENT:
  
 PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND
 EQUIPMENT.
  
 DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM
 DEVICES/EQUIPMENT.
  
 THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT
 DEMO AND CONSTRUCTION.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-03-24 Cont ID  
Sent By pleduc Date 2023-03-24 Time   Rev Time 0.00
Received By pleduc Date 2023-03-24 Time 11:59 Sent To  
Notes
2023-03-24 12:22:45FIRE PREVENTION COMMENT:
  
 PROTECT FIRE SPRINKLERS AND FIRE ALARM DEVICES AND
 EQUIPMENT.
  
 DO NOT PAINT OVER SPRINKLER HEADS AND/OR FIRE ALARM
 DEVICES/EQUIPMENT.
  
 THE FS AND FA SYSTEMS SHALL BE MAINTAINED THROUGHOUT
 DEMO AND CONSTRUCTION.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-06-05 Cont ID  
Sent By rwbrown Date 2023-06-05 Time 06:13 Rev Time 0.00
Received By rwbrown Date 2023-06-02 Time 07:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-05-31 Cont ID  
Sent By jwitmer Date 2023-05-31 Time 12:52 Rev Time 0.00
Received By jwitmer Date 2023-05-10 Time 09:49 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-04-05 Cont ID  
Sent By jgomez Date 2023-04-05 Time 14:47 Rev Time 0.00
Received By jgomez Date 2023-03-23 Time 10:31 Sent To I
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2023-03-29 Cont ID  
Sent By jwitmer Date 2023-03-29 Time 07:35 Rev Time 0.00
Received By jwitmer Date 2023-03-28 Time 16:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2023-05-11 Cont ID  
Sent By medwards Date 2023-05-11 Time 11:04 Rev Time 0.00
Received By medwards Date 2023-05-11 Time 11:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-03-31 Cont ID  
Sent By medwards Date 2023-03-31 Time 15:13 Rev Time 0.00
Received By medwards Date 2023-03-31 Time 15:13 Sent To  
Notes
2023-03-31 15:23:54WITH THE REPLACEMENT OF THE KITCHEN HOOD THE MECHANICAL
 DESIGN MUST PROVIDE A NEW AIR BALANCE DESIGN. FMC
 508.1.2
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-06-05 Cont ID  
Sent By rwbrown Date 2023-06-05 Time 06:12 Rev Time 0.00
Received By rwbrown Date 2023-06-05 Time 06:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-05-12 Cont ID  
Sent By rwbrown Date 2023-05-12 Time 09:13 Rev Time 0.00
Received By rwbrown Date 2023-05-12 Time 09:13 Sent To  
Notes
2023-05-12 09:20:112ND PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. THE DETAIL STILL HAS THE WORDS "NATURAL GAS FIRED
 INTANT HOT WATER HEATER" RIGHT ON THE WATER HEATER.
 2017 WPB AMENDS 107.2.1 - THE PLANS SHOW THE DETAIL FOR
 AN "ELECTRIC INSTANT HOT WATER HEATER" AND THE DETAIL
 ABOVE THAT TITLE SAYS "NATURAL GAS FIRED..." PLEASE FIX
  
 2. ALL HOT WATER MUST GO THROUGH A MIXING VALVE. PER
 THIS SECTION, THE THERMOSTAT CANNOT BE THE LIMITING
 DEVICE FOR ANY HOT WATER DELIVERY. IF YOU WANT 110 AND
 150 DEGREE WATER, YOU WILL NEED TWO MIXING VALVES.
 2020 FPC 607.1.1/613.1 - HOT WATER DELIVERY - PER THIS
 SECTION, THE THERMOSTAT ON THE WATER HEATER CANNOT
 SERVE AS THE LIMITING DEVICE FOR HOT OR TEMPERED WATER
 DELIVERY. A MIXING DEVICE MUST LIMIT THE TEMPERATURE.
 THE DEVICE MUST COMPLY WITH ASSE 1017 AND MUST BE
 INSTALLED AT THE HOT WATER SOURCE PER 2020 FPC 613.1.
 THIS IS IN ADDITION TO THE REQUIREMENTS FOR PUBLIC
 HANDWASHING PROTECTION FOR TEMPERED WATER
  
 3. PUBLIC HAND WASHING HAS A DIFFERENT REQUIREMENT AND
 NEEDS A 1070 DEVICE INSTALLED AT THE PUBLIC SINK. A
 DETAIL FOR THE PUBLIC SINK HAS NOT BEEN ADDED.
 2020 FPC 607.1.2/419.5 - PLEASE ADD A DETAIL AND SHOW
 COMPLIANCE FOR THE LIMITING DEVICE REQUIRED FOR PUBLIC
 HANDWASHING FACILITIES AND TEMPERED WATER. THE DEVICE
 SHOULD CONFORM TO ASSE 1070.
  
 4. NOT ADDRESSED.
 2017 WPB AMENDS 107.2.1 - PER THE CODE CASE PICTURES,
 THERE IS A WATER LINE NOT SHOWN ON THE PLANS. THE
 PICTURES SHOW A WATER LINE DIRECTLY ACROSS THE ROOM
 FROM THE PASTA BOILER.
  
 5. THE CODE CASE SHOWS "NEW" CPVC LINES. YOU HAVE NOW
 REMOVED THE NOTE FOR CPVC AND LABELED THEM AS EXISTING.
 THE WATER LINES WERE DESCRIBED AS NEW BY THE
 CONTRACTOR. THEY CANNOT BE LABELED AS EXISTING AS THEY
 NEED TO BE INSPECTED.
 2017 WPB AMENDS 107.2.1 - PER THE CODE CASE PICTURES,
 THERE IS NEW CPVC LINES INSTALLED. THE PLANS INDICATE
 "ALL NEW C.W. PIPING COPPER". PLEASE ADDRESS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-03-31 Cont ID  
Sent By rwbrown Date 2023-03-31 Time 11:55 Rev Time 0.00
Received By rwbrown Date 2023-03-31 Time 11:52 Sent To  
Notes
2023-03-31 12:01:531ST PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMENDS 107.2.1 - THE PLANS SHOW THE DETAIL
 FOR AN "ELECTRIC INSTANT HOT WATER HEATER" AND THE
 DETAIL ABOVE THAT TITLE SAYS "NATURAL GAS FIRED..."
 PLEASE FIX
  
 2. 2020 FPC 607.1.1/613.1 - HOT WATER DELIVERY - PER
 THIS SECTION, THE THERMOSTAT ON THE WATER HEATER CANNOT
 SERVE AS THE LIMITING DEVICE FOR HOT OR TEMPERED WATER
 DELIVERY. A MIXING DEVICE MUST LIMIT THE TEMPERATURE.
 THE DEVICE MUST COMPLY WITH ASSE 1017 AND MUST BE
 INSTALLED AT THE HOT WATER SOURCE PER 2020 FPC 613.1.
 THIS IS IN ADDITION TO THE REQUIREMENTS FOR PUBLIC
 HANDWASHING PROTECTION FOR TEMPERED WATER
  
 3. 2020 FPC 607.1.2/419.5 - PLEASE ADD A DETAIL AND
 SHOW COMPLIANCE FOR THE LIMITING DEVICE REQUIRED FOR
 PUBLIC HANDWASHING FACILITIES AND TEMPERED WATER. THE
 DEVICE SHOULD CONFORM TO ASSE 1070.
  
 4. 2017 WPB AMENDS 107.2.1 - PER THE CODE CASE
 PICTURES, THERE IS A WATER LINE NOT SHOWN ON THE PLANS.
 THE PICTURES SHOW A WATER LINE DIRECTLY ACROSS THE ROOM
 FROM THE PASTA BOILER.
  
 5. 2017 WPB AMENDS 107.2.1 - PER THE CODE CASE
 PICTURES, THERE IS NEW CPVC LINES INSTALLED. THE PLANS
 INDICATE "ALL NEW C.W. PIPING COPPER". PLEASE ADDRESS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-06-05 Cont ID  
Sent By rwbrown Date 2023-06-05 Time 06:13 Rev Time 0.00
Received By rwbrown Date 2023-06-05 Time 06:13 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-05-31 Cont ID  
Sent By jwitmer Date 2023-05-31 Time 12:48 Rev Time 0.00
Received By jwitmer Date 2023-05-31 Time 12:32 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-04-05 Cont ID  
Sent By jgomez Date 2023-04-05 Time 14:46 Rev Time 0.00
Received By jgomez Date 2023-04-05 Time 14:36 Sent To  
Notes
2023-03-31 15:25:58MECHANICAL DIGITAL SIGNATURES APROVED ME
2023-03-29 07:37:08ARCHITECTURAL SHEET OK 3/29/23 J WITMER


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved