| Plan Review Stops For Permit 23031345 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
P |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-05-08 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-05-08 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2023-05-08 09:57:46 | PARCEL DELETED FROM PAPA MOVING FORWARD WITH 529 S | | | FLAGLER DR 28E |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2023-04-25 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-04-25 |
Time |
09:14 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-04-25 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2023-04-25 09:20:32 | APPLICANT IS WORKING THROUGH THE DIFFERENT STEPS, THE | | | UNITY OF TITLE HAS BEEN RECORDED, THEY SHOULD BE | | | REQUESTING A SINGLE PCN FROM PAPA AND THEN REACHING OUT | | | TO ADDRESSING [email protected] OR CALL | | | 561-805-6659 TO BE ISSUED A SINGLE ADDRESS. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2023-04-10 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-04-10 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-04-10 |
Time |
12:12 |
Sent To |
|
|
| Notes |
| 2023-04-10 12:19:30 | PLANS INDICATE THAT AREA OF WORK ENCOMPASSES TWO | | | ADDRESSES 529 S FLAGLER DR 28E AND 28F AND TWO PARCELS | | | 74434322250002805 AND 74434322250002806. TWO UNITS WILL | | | NEED TO BE UNIFIED, YOU WILL NEED TO CONTACT VINCE NOEL | | | [email protected] OR CALL 561-494-1040 TO START THE UNITY | | | OF TITLE PROCEDURE. CURRENTLY THERE ARE TWO SEPARATE | | | PROPERTY CONTROL NUMBER (PCN) FOR THE TWO UNITS, YOU | | | WILL NEED TO GO FILL OUT PALM BEACH COUNTYS PARCEL | | | COMBINATION REQUEST FORM WHICH CAN BE FOUND AT THIS | | | LINK HTTPS://WWW.PBCGOV.ORG/PAPA/DEPARTMENTS/GIS.HTM, | | | THEY WILL ISSUE YOU WITH A UNIFIED PARCEL CONTROL | | | NUMBER (PCN). WHEN YOU CONTACT THE PROPERTY APPRAISERS | | | YOU NEED TO REQUEST PRELIMINARY LETTER OF THE UNIFIED | | | PCN. ONCE YOU HAVE RECEIVED THE PRELIMINARY LETTER | | | PLEASE CONTACT [email protected] OR CALL | | | 561-805-6659 TO BE ISSUED AN ADDRESS. |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
P |
Date |
2023-03-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-03-28 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-03-28 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2023-03-28 15:22:40 | TO THE BUILDING CONTRACTOR: | | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON THE CONTRACTOR???S LETTERHEAD, STATING | | | THAT THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS | | | PROGRAM COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM | | | BEACH COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION | | | WILL BE GIVEN TIMELY. | | | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | | CAN BE FOUND ON THEIR WEBSITE: | | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | | -RENOVATION.HTML | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | | [email protected]. THE INFORMATION SHOULD BE IN | | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | | LINE. | | | | | | JAMES A. WITMER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-05-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-05-23 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-05-23 |
Time |
15:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-05-08 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-05-08 |
Time |
11:12 |
Sent To |
|
|
| Notes |
| 2023-05-08 11:50:13 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 23031345 | | | ADD: 529 S FLAGLER DR # 28E | | | CONT: CAMBRIDGE CONSTRUCTION LLC | | | TEL: 561-784-3722 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: MON. MAY 08/2023 | | | ACTION: DENIED | | | | | | 1) SHEET A-100: | | | 1A) SEMI-COMPLIED. NOTE # 7 STATES NEW 5/8-INCH DRYWALL | | | OVER 1/2-INCH PLYWOOD. PLEASE NOTE THIS IS A HIGHRISE | | | BUILDING, IF WOOD IS TO BE USED WITHIN WALL CAVITIES. | | | PLEASE REVIEW IN THE 2020 FBC-BUILDING SECTION 603.1. | | | FIRE RETARDANT TREATED WOOD SHALL BE PERMITTED IN: | | | 603.1.1. NONBEARING PARTITIONS WHERE THE REQUIRED | | | FIRE-RESISTANCE RATING IS 2 HOURS OR LESS. | | | | | | 1B) 2ND REQUEST. TEST REPORTS ONLY NOT SPECS. NOTE # 10 | | | STATES INSTALL NEW WOOD FLOORS OVER PROFLEX MSC 90 | | | ACOUSTIC MEMBRANE TO MATCH EXISTING. TEST REPORTS NEED | | | TO MATCH THE MATERIAL BEING INSTALLED. WE HAVE NOT SEEN | | | PROFLEX MSC 90 TESTED FOR WOOD OR WOOD LAMINATES. | | | PROFLEX DOES HAVE A PRODUCT PROFLEX LV-200 WHICH THE | | | CITY IS IN RECEIPT OF ALL TEST REPORTS. | | | FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE, | | | STONE, MARBLE, VINYL (LYT/ LYP), LAMINATE FLOORING AND | | | WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND | | | UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING | | | STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH | | | OF THE STANDARDS FOR A 6-INCH CONCRETE FLOOR ASSEMBLY/ | | | NO DROPPED CEILING: | | | PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR | | | TYPE II BUILDINGS SHOWING COMPLIANCE WITH: | | | | | | 1B)(1) 2ND REQUEST. FBC-B 2020 1207.3 STRUCTURE-BORNE | | | SOUND. FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS | | | OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | | | 1B)(2) 2ND REQUEST. FBC-B 2020 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 1B)(3) 2ND REQUEST. FLAME SPREAD- FBC-B 2020 603.1. | | | EXCEPTION 2. (TILE & MARBLE) INSULATION INSTALLED | | | BETWEEN A FINISHED FLOOR AND SOLID DECKING WITHOUT | | | INTERVENING AIRSPACE SHALL BE ALLOWED TO HAVE A FLAME | | | SPREAD INDEX OF NOT MORE THAN 200. | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | OR | | | 1B)(3) 2ND REQUEST. FBC-B 804.4.4.1 SOFT FLOOR FINISHES | | | (LVT/ LPT OR LAMINATED OR ENGINEERED WOOD FLOORING) | | | WITHIN TENANT SPACE. INTERIOR FLOOR COVERING MATERIALS | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE COC FF-1 | | | -PILL TEST (CPSC 16 CFR PART 1630) OR WITH ASTM D2859. | | | LVT & LPT LUXURY VINYL TILE. FLOOR FINISH | | | CLASSIFICATION AS REQUIRED IN SECTION 804.2 | | | CLASSIFICATION AND 804.3 TESTING AND IDENTIFICATION OF | | | THE 2020 FBC-B. 804.2 & 804.3/ ASTM E648 OR NFPA 253. | | | | | | 2) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT | | | REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE. | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-03-28 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-03-28 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2023-03-28 16:37:57 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 23031345 | | | ADD: 529 S FLAGLER DR # 28E | | | CONT: CAMBRIDGE CONSTRUCTION LLC | | | TEL: 561-784-3722 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. MARCH 28/2023 | | | ACTION: DENIED | | | | | | 1) SHEET A-100: | | | 1A) NOTE # 7 STATES NEW 5/8-INCH DRYWALL OVER ??-INCH | | | PLYWOOD WITH BATT INSULATION IN 2X4 OR 2X6 STUD SPACE. | | | PLEASE NOTE THIS IS A HIGHRISE BUILDING, IF WOOD IS TO | | | BE USED WITHIN WALL CAVITIES. PLEASE REVIEW IN THE 2020 | | | FBC-BUILDING SECTION 603.1. FIRE RETARDANT TREATED WOOD | | | SHALL BE PERMITTED IN: | | | 603.1.1. NONBEARING PARTITIONS WHERE THE REQUIRED | | | FIRE-RESISTANCE RATING IS 2 HOURS OR LESS. | | | | | | 1B) NOTE # 10 STATES INSTALL NEW WOOD FLOORS OVER | | | PROFLEX SUPER SIM 90 ACOUSTIC MEMBRANE TO MATCH | | | EXISTING. PLEASE NOTE DOCUMENTS SUBMITTED ARE WHISPER | | | MAT CS FOR SOUND AND FLAME SPREAD NOT PROFLEX SUPER SIM | | | 90. BOTH PRODUCT WERE TEST FOR CERAMIC OR PORCELAIN | | | TILE NOT FOR WOOD FLOORS. PROFLEX MAKES A PRODUCT THAT | | | IS TESTED FOR WOOD LAMINATE FLOORING STC 50 AND IIC 54 | | | WITH FLAME SPREAD TESTING. | | | FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE, | | | STONE, MARBLE, VINYL (LYT/ LYP), LAMINATE FLOORING AND | | | WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND | | | UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING | | | STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH | | | OF THE STANDARDS FOR A 6-INCH CONCRETE FLOOR ASSEMBLY/ | | | NO DROPPED CEILING: | | | PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR | | | TYPE II BUILDINGS SHOWING COMPLIANCE WITH: | | | | | | 1B)(1) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | | | 1B)(2) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS, | | | PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING | | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR | | | AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E | | | 90. | | | | | | 1B)(3) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2. | | | (TILE & MARBLE) INSULATION INSTALLED BETWEEN A FINISHED | | | FLOOR AND SOLID DECKING WITHOUT INTERVENING AIRSPACE | | | SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT | | | MORE THAN 200. | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | OR | | | 1B)(3) FBC-B 804.4.4.1 SOFT FLOOR FINISHES (LVT/ LPT OR | | | LAMINATED OR ENGINEERED WOOD FLOORING) WITHIN TENANT | | | SPACE. INTERIOR FLOOR COVERING MATERIALS SHALL COMPLY | | | WITH THE REQUIREMENTS OF THE COC FF-1 -PILL TEST (CPSC | | | 16 CFR PART 1630) OR WITH ASTM D2859. | | | LVT & LPT LUXURY VINYL TILE. FLOOR FINISH | | | CLASSIFICATION AS REQUIRED IN SECTION 804.2 | | | CLASSIFICATION AND 804.3 TESTING AND IDENTIFICATION OF | | | THE 2020 FBC-B. 804.2 & 804.3/ ASTM E648 OR NFPA 253. | | | | | | 2) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT | | | REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE. | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-05-01 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-05-01 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-05-01 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-05-01 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-04-06 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-04-06 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2023-04-06 10:10:37 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | | IS ADEQUATE. | | | NEC 220 | | | 2. PROVIDE PANEL SCHEDULE SHOWING THE FOLLOWING | | | INFORMATION: | | | A. PANEL RATING WITH PROTECTION (MAIN BREAKER) RATING | | | B. PANEL SCHEDULE SHOWING NEW EQUIMENT INSTALLED | | | NEC 408.4(A) | | | | | | END OF COMMENTS | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | RUBEN PEREZ PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6738 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2023-05-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-05-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-05-16 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2023-05-16 11:53:01 | FIRE PROVISO: | | | | | | DUE TO THE RECONSTRUCTION, THE FIRE SPRINKLER | | | PROTECTION REQUIRES MODIFICATION. | | | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | | DRAWINGS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-04-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-04-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-04-26 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2023-04-26 10:49:23 | FIRE PROVISO: | | | | | | DUE TO THE RECONSTRUCTION, THE FIRE SPRINKLER | | | PROTECTION REQUIRES MODIFICATION. | | | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | | DRAWINGS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-03-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-03-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-03-24 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2023-03-24 11:58:11 | FIRE PROVISO: | | | | | | DUE TO THE RECONSTRUCTION, THE FIRE SPRINKLER | | | PROTECTION REQUIRES MODIFICATION. | | | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | | DRAWINGS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-05-31 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-31 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-26 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-05-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-23 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-15 |
Time |
08:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-05-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-04-20 |
Time |
08:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-04-10 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2023-04-10 |
Time |
12:19 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2023-03-23 |
Time |
10:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2023-03-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-03-28 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-03-28 |
Time |
15:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2023-05-31 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-31 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-31 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2023-05-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-23 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-23 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2023-05-23 17:31:30 | PLAN DENIED | | | 1) MECHANICAL PLAN MUST INCLUDE THE ARCHITECTS DIGITAL | | | SIGNATURE. FS 471/481 | | | 2) EQUIPMENT SCHEDULE FOR NEW EQUIPMENT REQUIRED | | | ON THE PLAN. SECTION 107 WPB AMENDMENTS. | | | 3) ERFER TO SECTION 107.2.1.4 QUALITY PLAN | | | WPB AMENDMENTS. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-05-02 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-05-02 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2023-05-02 10:17:26 | THE MECHANICAL DRAWING MUST INCLUDE THE ARCHITECTS | | | DIGITAL SIGNATURE. FS 471/481 | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-31 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-31 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-31 |
Time |
16:05 |
Sent To |
|
|
| Notes |
| 2023-03-31 16:05:51 | 1ST REVIEW FMC | | | PERMIT: 23031345 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | PROVIDE A SCOPE OF WORK AND MECHANICAL DESIGN FOR THE | | | MECHANICAL WORK BEING COMPLETED IN THIS PROJECT. THIS | | | SHOULD BE SUBMITTED FOR REVIEW UNDER THIS MASTER PERIT. | | | A MECHANICAL SUB PERMIT WILL ALSO BE REQUIRED. FBC | | | 107.3.5 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-04-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-04-21 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-04-21 |
Time |
16:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-03-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-03-30 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-03-30 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2023-03-30 12:03:11 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 23031345 | | | 3/29/23 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SIGNATURE ERROR: THE PLUMBING PLANS P0.1 & P1.1 | | | CANNOT BE APPROVED DUE TO A SIGNATURE ERROR WHICH | | | TERMINATED THE VERIFICATION PROCESS. PLANS DESIGNED BY | | | ENGINEERS AND UPLOADED FOR REVIEW SHALL HAVE VERIFIABLE | | | DIGITAL SIGNATURES AND SEALS BY THE ENGINEER AS | | | REQUIRED BY FL. STATUTE 471.025 AND SEC. 61G15-23.005 | | | FLORIDA ADMINISTRATIVE CODE. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2023-05-31 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-31 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-31 |
Time |
13:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2023-05-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-23 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-23 |
Time |
17:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-05-08 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-05-08 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2023-05-08 11:55:52 | FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) PLANS | | | IN THE FILE FOLDER, SCANNED, FACSIMILE, DIGITALLY | | | CREATED OR COPIED IMAGE OF THE LICENSEE???S SIGNATURE | | | SHALL NOT BE USED ON ELECTRONIC/DIGITALLY SIGNED AND | | | SEALED ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR | | | OTHER DOCUMENTS.SIGNATURE FILE DOES NOT OPEN FOR | | | VERIFIACATION. | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-04-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-04-10 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-04-10 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2023-04-10 10:46:18 | 1ST SIGNATURE REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: ALL PLAN PAGES ??? | | | | | | 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A | | | VALID DIGITAL SIGNATURE. | | | A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE | | | IS NOT CONSIDERED A VALID DIGITAL SIGNATURE. | | | | | | 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S. | | | 668.003 (3); | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5). | | | F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS) | | | F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | 2023-03-30 12:04:06 | SIGNATURE ERROR: THE PLUMBING PLANS P0.1 & P1.1 CANNOT | | | BE APPROVED DUE TO A SIGNATURE ERROR WHICH TERMINATED | | | THE VERIFICATION PROCESS. PLANS DESIGNED BY ENGINEERS | | | AND UPLOADED FOR REVIEW SHALL HAVE VERIFIABLE DIGITAL | | | SIGNATURES AND SEALS BY THE ENGINEER AS REQUIRED BY FL. | | | STATUTE 471.025 AND SEC. 61G15-23.005 FLORIDA | | | ADMINISTRATIVE CODE. | | 2023-03-28 16:41:45 | ARCHITECTURAL SHEETS APPEAR TO BE PAPER PLANS WITH WET | | | INK SEAL. FLORIDA ADMINISTRATIVE CODE 61G15-23.005 | | | (3)(C) PLANS IN THE PLAN FILE FOLDER, SCANNED, | | | FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE OF THE | | | LICENSEE???S SIGNATURE SHALL NOT BE USED ON | | | ELECTRONIC/DIGITALLY SIGNED AND SEALED PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | |
|
|