| Plan Review Stops For Permit 23031303 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
P |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-20 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-20 |
Time |
11:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-04-27 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-27 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-27 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-20 |
Time |
11:59 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-20 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2023-04-20 11:59:02 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23031303 | | | | | | REVIEWED: 4/20/2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | FBC ACCESSIBITILY | | | | | | COMMENTS: | | | | | | SHEET A-1 | | | SECTION 804 KITCHENS | | | 804.2.1.PLEASE COMPLY TO PASS-THROUGH KITCHEN | | | REQUIREMENT AND INDICATE THE CLEAR 40" PATH. | | | ADJUST MILLWORK PLAN ACCORDINGLY IF REQUIRED AND | | | RESUBMIT. | | | | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-05-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-05-03 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-05-03 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-04-24 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-04-24 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-04-24 |
Time |
13:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-03-29 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2023-03-29 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-03-29 10:23:27 | FIRE PROVISO COMMENTS: | | | | | | (1) ALL EXISTING LIFE SAFETY SYSTEMS (I.E. FIRE ALARM) | | | SHALL REMAIN OPERATIONAL DURING ALL PHASES OF | | | DEMOLITION AND CONSTRUCTION. | | | | | | (2) ALL EXISTING LIFE SAFETY SYSTEMS (I.E. FIRE ALARM) | | | SHALL BE PROTECTED FROM DAMAGE DURING ALL PHASES OF | | | DEMOLITION AND CONSTRUCTION. | | | | | | (3) ANY WORK PERFORMED ON ANY LIFE SAFETY SYSTEM (I.E. | | | FIRE ALARM) SHALL ONLY BE CONDUCTED BY PROPERLY | | | LICENSED AND QUALIFIED CONTRACTORS AND MAY REQUIRE | | | SEPARATE PERMITS AND SHOP DRAWINGS. | | | | | | (4) ALL INTERIOR FINISHES SHALL COMPLY WITH THE LIFE | | | SAFETY CODE, NFPA 101, CHAPTER 10. | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-05-03 |
Time |
15:53 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-04-26 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-04-26 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-04-26 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-28 |
Time |
15:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2023-04-26 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-04-26 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-04-26 |
Time |
07:26 |
Sent To |
|
|
| Notes |
| 2023-04-26 07:26:58 | NO MECHANICAL WORK SHOWN IN THE SCOPE OF WORK FOR THIS | | | PROJECT. ME |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-04-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-04-27 |
Time |
11:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-04-27 |
Time |
10:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-04-20 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-04-19 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2023-04-20 08:49:26 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT-23031303 | | | 4/20/23 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) P1.1 GREASE INTERCEPTOR: THE GREASE INTERCEPTOR | | | PERMIT APPLICATION IS REQUIRED TO BE SUBMITTED PRIOR TO | | | THE MAIN PLUMBING PLAN APPROVAL. YOU CAN SUBMIT AN | | | APPLICATION ???TBD??? (TO BE DETERMINED) IF YOU DO NOT | | | HAVE A CONTRACTOR SELECTED BY EMAILING A COMPLETED | | | PERMIT APPLICATION TO [email protected]. YOU WILL | | | RECEIVE INSTRUCTIONS TO PAY FEES AND UPLOAD PLANS. YOU | | | MAY UPLOAD PLANS AND PAY FEES AT A FUTURE DATE, BUT THE | | | APPLICATION IS REQUIRED AT THIS TIME. WE RECOMMEND THAT | | | YOU PAY FEES AND UPLOAD PLANS AT THE SAME TIME. AFTER | | | YOU HAVE THE PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL | | | ([email protected]) AND I WILL CHANGE THE REVIEW STATUS TO | | | PASS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-04-27 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-27 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-27 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-20 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-20 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2023-04-20 08:39:36 | PLUMBING AND KITCHEN (P& K) PLANS PASSED. |
|
|