Plan Review Details - Permit 23031183
Plan Review Stops For Permit 23031183
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-04-17 Cont ID  
Sent By lbond Date 2023-04-17 Time 11:07 Rev Time 0.00
Received By lbond Date 2023-04-17 Time 11:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-28 Cont ID  
Sent By lbond Date 2023-03-28 Time 15:14 Rev Time 0.00
Received By lbond Date 2023-03-28 Time 15:14 Sent To  
Notes
2023-03-28 15:15:33MUST COMPLY TO ALL TRADES AND SIGNATURE COMMENTS FIRST.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-04-17 Cont ID  
Sent By jcooley Date 2023-04-17 Time 19:17 Rev Time 0.00
Received By jcooley Date 2023-04-17 Time 19:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-03-28 Cont ID  
Sent By jcooley Date 2023-03-28 Time 18:48 Rev Time 0.00
Received By jcooley Date 2023-03-28 Time 07:12 Sent To  
Notes
2023-03-28 18:51:02ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN
 PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER.
 FBC 107.2.1
 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF
 SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE,
 WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY
 SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW
 INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230,
 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1,
 E3609.3; WPB FBC 107.2.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
  
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 JONATHAN COOLEY
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 (561)345-4377
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-04-17 Cont ID  
Sent By pleduc Date 2023-04-17 Time   Rev Time 0.00
Received By pleduc Date 2023-04-17 Time 10:51 Sent To  
Notes
2023-04-17 11:02:15FIRE PROVISO:
  
 THE PROPOSED TRAILER IS TOO CLOSE TO THE PROPOSED
 BUILDING PER NFPA 241, AND REQUIRES FIRE SPRINKLER
 PROTECTION.
  
 PER NFPA 241, WITH A 64' WIDTH OF EXPOSURE, THE TRAILER
 IS REQUIRED TO BE AT LEAST 50' AWAY FROM THE BUILDING.
  
 FIRE SPRINKLERS WILL PROVIDE FOR A 75% REDUCTION.
  
 HOWEVER, THE INSTALLATION OF ABC DRY CHEMICAL
 SPRINKLERS PER MANUFACTURERS RECOMMENDATIONS WILL BE
 CONSIDERED IN LIEU OF WET FIRE SPRINKLERS.
  
 PLEASE ENSURE THEY ARE INSTALLED.
  
 CONTACT MY OFFICE SHOULD YOU HAVE ANY QUESTIONS OR
 CONCERNS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-03-24 Cont ID  
Sent By pleduc Date 2023-03-24 Time   Rev Time 0.00
Received By pleduc Date 2023-03-24 Time 10:01 Sent To  
Notes
2023-03-24 10:06:32THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS AN INDICATION OF A DOUBLE WIDE CONSTRUCTION
 TRAILER, HOWEVER, THERE IS NO SITE/LOT PLAN INDICATING
 THE PROPOSED LOCATION OF THE TRAILER.
  
 THE TRAILER IS REQUIRED TO BE SEPARATE FROM THE
 PROPOSED NEW STRUCTURE OR NEARBY STRUCTURES DUE TO THE
 THREAT OF FIRE AND EXPOSURE TO THESE STRUCTURES.
  
  
  
 PER NFPA 241, 4.2 TEMPORARY OFFICES AND SHEDS;
  
 TABLE 4.2.1 SEPARATION DISTANCES, FIRE SPRINKLERS ARE
 REQUIRED IN EACH TRAILER.
  
 4.2.1* SEPARATION DISTANCES BETWEEN BUILDINGS UNDER
 CONSTRUCTION AND CONSTRUCTION-RELATED STRUCTURES, SUCH
 AS TEMPORARY OFFICES, TRAILERS, SHEDS, AND OTHER
 FACILITIES FOR THE STORAGE OF TOOLS AND MATERIALS
 HAVING COMBUSTIBLE CONSTRUCTION OR CONTENTS, SHALL BE
 IN ACCORDANCE WITH TABLE 4.2.1.
  
 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 30 FEET
 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 35 FEET
 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 40 FEET
 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 45 FEET
 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 50 FEET
 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE
 SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET
 **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL
 BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC
 SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE.
  
 NOTES:
 (1) WHERE THE SEPARATION DISTANCE BETWEEN TEMPORARY
 STRUCTURES IS LESS THAN THE MINIMUM SEPARATION
 DISTANCE, THEN THE EXPOSING WALL LENGTH SHALL BE
 CONSIDERED TO BE THE SUM OF THE INDIVIDUAL EXPOSING
 WALL LENGTHS OF THE TEMPORARY STRUCTURES.
 (2) A 75 PERCENT REDUCTION IN SEPARATION DISTANCES
 SHALL BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC
 SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE.
 (3) THE SEPARATION DISTANCES APPLY TO SINGLE-LEVEL
 STRUCTURES ONLY. THIS TABLE DOES NOT APPLY TO
 MULTILEVEL, UNSPRINKLERED STRUCTURES. A LEVEL, WHERE
 APPLYING THIS TABLE, IS 3600 MM (144 IN.).
  
 4.2.2* DETACHMENT BETWEEN TEMPORARY STRUCTURES,
 ADEQUATE TEMPORARY FIXED FIRE PROTECTION SYSTEMS, AND
 PORTABLE EQUIPMENT SHALL BE PROVIDED AS REQUIRED BY THE
 AUTHORITY HAVING JURISDICTION.
  
 PLEASE PROVIDE FOR THE REQUIRED SEPARATION DIMESIONS ON
 A SITE/LOT PLAN OR PROVIDE FIRE SPRINKLER PROTECTION.
  
 FYI: THE INSTALLATION OF ABC DRY CHEMICAL SPRINKLERS
 PER MANUFACTURERS RECOMMENDATIONS MAY BE CONSIDERED IN
 LIEU OF WET FIRE SPRINKLERS.
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-05-22 Cont ID  
Sent By lmarchan Date 2023-05-22 Time 07:38 Rev Time 0.00
Received By lmarchan Date 2023-04-14 Time 14:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-04-14 Cont ID  
Sent By aoliver Date 2023-04-14 Time 08:58 Rev Time 0.00
Received By aoliver Date 2023-03-23 Time 12:59 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2023-03-24 Cont ID  
Sent By medwards Date 2023-03-24 Time 15:45 Rev Time 0.00
Received By medwards Date 2023-03-24 Time 15:45 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-04-17 Cont ID  
Sent By rwbrown Date 2023-04-17 Time 14:33 Rev Time 0.00
Received By rwbrown Date 2023-04-17 Time 14:33 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-04-17 Cont ID  
Sent By rwbrown Date 2023-04-17 Time 07:14 Rev Time 0.00
Received By rwbrown Date 2023-04-17 Time 07:14 Sent To  
Notes
2023-04-17 07:14:532ND PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMEND - 105.1/107.3 -- A BACKFLOW IS
 REQUIRED TO CONNECT THE WATER SUPPLY. THE BACKFLOW
 DEVICE AT THE UTILITY CONNECTION REQUIRES A SEPARATE
 PERMIT. YOU CAN SUBMIT AN APPLICATION "TBD" (TO BE
 DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY
 EMAILING A COMPLETED PERMIT APPLICATION TO
 [email protected]. AFTER YOU HAVE THE PERMIT(S)
 GENERATED, NOTIFY ME VIA EMAIL OR NOTE IN THE RESPONSE
 LETTER AND I WILL COMPLY THIS COMMENT.
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-03-27 Cont ID  
Sent By rwbrown Date 2023-03-27 Time 13:14 Rev Time 0.00
Received By rwbrown Date 2023-03-27 Time 13:09 Sent To  
Notes
2023-03-27 13:51:471ST PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMEND - 105.1/107.3 -- A BACKFLOW IS
 REQUIRED TO CONNECT THE WATER SUPPLY. THE BACKFLOW
 DEVICE AT THE UTILITY CONNECTION REQUIRES A SEPARATE
 PERMIT. YOU CAN SUBMIT AN APPLICATION "TBD" (TO BE
 DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY
 EMAILING A COMPLETED PERMIT APPLICATION TO
 [email protected]. AFTER YOU HAVE THE PERMIT(S)
 GENERATED, NOTIFY ME VIA EMAIL OR NOTE IN THE RESPONSE
 LETTER AND I WILL COMPLY THIS COMMENT.
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status N Date 2023-05-22 Cont ID  
Sent By lmarchan Date 2023-05-22 Time 07:37 Rev Time 0.00
Received By lmarchan Date 2023-05-22 Time 07:37 Sent To  
Notes
2023-05-22 07:38:10PER GATHRIGHT, RECEIVED NOTE STATING CONSTRUCTION
 TRAILER WILL NOT BE UNDER PRIVATE PROVIDER'S SCOPE. LEM

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2023-04-14 Cont ID  
Sent By jbaker Date 2023-04-14 Time 08:32 Rev Time 0.00
Received By jbaker Date 2023-04-14 Time 08:31 Sent To  
Notes
2023-04-14 08:34:51THERE IS NO NOTICE TO BUILDING OFFICIAL OR CERTIFICATE
 OF INSURANCE UPLOADED TO PROJECT DOCUMENTS TO CHECK.
 PLEASE PROVIDE BOTH.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-04-17 Cont ID  
Sent By lbond Date 2023-04-17 Time 11:21 Rev Time 0.00
Received By lbond Date 2023-04-17 Time 11:26 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-03-28 Cont ID  
Sent By lbond Date 2023-03-28 Time 15:11 Rev Time 0.00
Received By lbond Date 2023-03-28 Time 15:11 Sent To  
Notes
2023-03-28 15:14:16BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 23031183
  
 REVIEWED: MARCH 28, 2023
  
 FLORIDA BUILDING CODE,7TH EDITION (2020)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC BUILDING
 FBC EXISTING BUILDING
  
 COMMENTS:
  
 PLANS BY FL. LICENSES ENGINEERS OR ARCHITECTS THAT ARE
 SUBMITTED ELECTRONICALLY SHALL BEAR VERIFIABLE,
 ORIGINAL DIGITAL SIGNATURE AND SEALS- FL STATUTE
 471.025 AND SEC 61G15-23.005 FLORIDA ADMINISTRATIVE
 CODE.
  
 IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT
 HESITATE TO CONTACT ME
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
  
 NOTES:
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  

Review Stop Z ZONING
Rev No 2 Status P Date 2023-05-09 Cont ID  
Sent By vbroglia Date 2023-05-09 Time 12:48 Rev Time 0.00
Received By vbroglia Date 2023-05-09 Time 12:48 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2023-04-13 Cont ID  
Sent By AJVann Date 2023-04-13 Time 16:37 Rev Time 0.00
Received By ajones Date 2023-04-13 Time 16:37 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy