Plan Review Details - Permit 23031171
Plan Review Stops For Permit 23031171
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2023-04-13 Cont ID  
Sent By lbond Date 2023-04-13 Time 09:33 Rev Time 0.00
Received By lbond Date 2023-04-13 Time 09:33 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-03-31 Cont ID  
Sent By lbond Date 2023-03-31 Time 12:01 Rev Time 0.00
Received By lbond Date 2023-03-31 Time 12:01 Sent To  
Notes
2023-03-31 12:03:18BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 23031171
  
 REVIEWED: MARCH 31, 2023
  
 FLORIDA BUILDING CODE,7TH EDITION (2020)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC BUILDING
 FBC EXISTING BUILDING
  
 COMMENT:
  
 ASBESTOS REVIEW:
  
 FAILED PLAN REVIEW:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC
 ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION
 -RENOVATION.HTML
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
  
 NOTES:
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-04-13 Cont ID  
Sent By lbond Date 2023-04-13 Time 09:39 Rev Time 0.00
Received By lbond Date 2023-04-13 Time 09:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-31 Cont ID  
Sent By lbond Date 2023-03-31 Time 12:05 Rev Time 0.00
Received By lbond Date 2023-03-31 Time 12:05 Sent To  
Notes
2023-03-31 12:09:04PLEASE COMPLY TO FIRE COMMENTS AND OTHER TRADES IF
 APPLICATBLE AND INLCUDE FLOOR FINISH SHEDULE WITH NOA
 OR FBC APPROVED UNDERLAYMENT IF REQUIRED AND SIGNED
 PLAN BY PALM BEACH CONTRACTOR AND CONTACT INFO WHO WILL
 INSTALL THE NEW FLOORING-
 OR DETAIL AND NOTES ON THE ARCHITECTURAL SIGNED AND
 SEALED PLAN.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-04-13 Cont ID  
Sent By rperdomo Date 2023-04-13 Time 16:42 Rev Time 0.00
Received By rperdomo Date 2023-04-13 Time 16:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-04-04 Cont ID  
Sent By rperdomo Date 2023-04-04 Time 09:34 Rev Time 0.00
Received By rperdomo Date 2023-04-04 Time 09:11 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-04-13 Cont ID  
Sent By pleduc Date 2023-04-13 Time   Rev Time 0.00
Received By pleduc Date 2023-04-13 Time 09:42 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-03-30 Cont ID  
Sent By pleduc Date 2023-03-30 Time   Rev Time 0.00
Received By pleduc Date 2023-03-30 Time 10:24 Sent To  
Notes
2023-03-30 10:45:22THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS AN INDICATION ON THE SUBMITTED PLANS OF
 REMOVING ALL FLOORING BUT NO INDICATION OF NEW FLOORING
 NOR A SPEC SHEET NOR A PRODUCT NAME FOR THE ACTUAL
 PROPOSED FLOORING.
  
 FFLOORING IS MANUFACTURED AROUND THE WORLD BUT NOT ALL
 ARE TESTED AND MEETING LISTED AND NFPA STANDARDS.
  
 PER NFPA 101, CH 30
  
 30.3.3.3 INTERIOR FLOOR FINISH.
 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN
 ACCORDANCE WITH
 SECTION 10.2.
  
 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH
 10.2.2.2
 ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL
 HAVE A
 MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2.
  
 FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE VINYL
 FLOORING NAME AND THE PRODUCT SPEC SHEETS INDICATING
 THE FIRE BEHAVIOR RATING.
  
 IF THE PROPOSED FLOORING IS PORCELAIN/CERAMIC TILE,
 NATURAL STONE TILE, CONCRETE TILES, PRODUCT SPEC SHEETS
 WOULD NOT BE REQUIRED.
  
 PRODUCT SPEC SHEETS ARE REQUIRED FOR LVT, VINYL
 FLOORING, WOOD/VINYL LAMINATES, ETC.
  
  
  
 2) IT IS UNCLEAR IF THERE ARE FIRE ALARM DEVICES ON THE
 WALL THAT IS BEING REMOVED AND RECONSTRUCTED.
  
 SHOULD THERE BE ANY FIRE ALARM DEVICES ON THAT WALL AND
 IT NEEDS TO BE RELOCATED, THE FIRE ALARM SYSTEMS SHALL
 BE MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
 AND ANY WORK ON THE FIRE ALARM SYSTEM, INCLUDING DEMO,
 SHALL BE DONE UNDER SEPARATE PERMITS & SHOP DRAWINGS.
  
 PLEASE REVIEW AND PROVIDE AN APPLICALE NOTE ON THE
 ELECTRICAL PLAN
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-04-14 Cont ID  
Sent By medwards Date 2023-04-14 Time 13:50 Rev Time 0.00
Received By medwards Date 2023-04-12 Time 18:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-04-05 Cont ID  
Sent By aoliver Date 2023-04-05 Time 08:58 Rev Time 0.00
Received By aoliver Date 2023-03-29 Time 08:11 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2023-04-14 Cont ID  
Sent By medwards Date 2023-04-14 Time 13:48 Rev Time 0.00
Received By medwards Date 2023-04-14 Time 13:48 Sent To  
Notes
2023-04-14 13:49:07LIKE FOR LIKE CHANGE OUT. NO PLAN REVIEW REQUIRED.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-03-31 Cont ID  
Sent By medwards Date 2023-03-31 Time 12:34 Rev Time 0.00
Received By medwards Date 2023-03-31 Time 12:34 Sent To  
Notes
2023-03-31 12:36:12SHEET A-3 OF 4 KEYNOTE H: PROVIDE THE LIKE FOR LIKE
 CHANGE OUT FORM FOR THE MECHANICAL SYSTEM ALSO, A
 MECHANICAL SUBPERMIT WILL BE REQUIREMENT FOR THIS LIKE
 FOR LIKE CHANGE OUT.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-04-13 Cont ID  
Sent By ccole Date 2023-04-13 Time 10:10 Rev Time 0.00
Received By ccole Date 2023-04-13 Time 10:04 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-04-03 Cont ID  
Sent By ccole Date 2023-04-03 Time 13:03 Rev Time 0.00
Received By ccole Date 2023-04-03 Time 12:18 Sent To  
Notes
2023-04-03 13:04:101ST REVIEW FBC-2020 PLUMBING
 PERMIT-23031171
 4/3/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-4: THE RISER APPEARS TO MISREPRESENT ACTUAL
 FIELD CONDITIONS BECAUSE IT SHOWS THE WASHING MACHINE
 FIXTURE DRAIN DISCHARGING INTO THE MAIN SOIL STACK
 INSTEAD OF A SEPARATE WASTE STACK- SEE SEC. 202 FBC P.
 FOR DEFINITION OF WASTE. TYPICALLY, MULTI-STORY
 PLUMBING DESIGN WOULD PROVIDE SEPARATE WASTE AND SOIL
 STACKS- SEC. 107.2.1 WPB.
  
 2) A-4: THE PLAN SHEET IS NOT DIGITALLY SIGNED AND
 SEALED BY THE ARCHITECT OF RECORD RODNEY NORTH GREEN-
 FL. STATUTE 481.221 AND SEC. 61G1-16.005 FAC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status N Date 2023-04-13 Cont ID  
Sent By lbond Date 2023-04-13 Time 09:36 Rev Time 0.00
Received By lbond Date 2023-04-13 Time 09:36 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2023-03-31 Cont ID  
Sent By dbattles Date 2023-03-31 Time 13:49 Rev Time 0.00
Received By dbattles Date 2023-03-31 Time 13:46 Sent To  
Notes
2023-03-31 13:53:551. 553.791, F.S. NOTICE TO BUILDING OFFICIAL
 - PLEASE PROVIDE NOTICE TO BUILDING OFFICIAL. UPLOAD
 INTO SUPPORTING DOCUMENTS IN PROJECTDOX.
  
 2. CERTIFICATE OF INSURANCE FOR PROFESSIONAL LIABILITY
 OF FIRM. MINIMUM COVERAGE OF $1,000,000.00 PER
 OCCURRENCE AND $2,000,000.00 AGGREGATE ARE REQUIRED.
 F.S. 553.791 (4) (B) AND (16). CERTIFICATE OF INSURANCE
 FOR PROFESSIONAL LIABILITY OF FIRM. MINIMUM COVERAGE OF
 $1,000,000.00 PER OCCURRENCE AND $2,000,000.00
 AGGREGATE ARE REQUIRED. F.S. 553.791 (4) (B) AND (16).
 IN THE DESCRIPTION OF OPERATIONS PLEASE ADD LANGUAGE TO
 STATE ""THE PROFESSIONAL LIABILITY POLICY INCLUDES AN
 EXTENDED REPORTING PERIOD ENDORSEMENT (TAIL COVERAGE)
 FOR FIVE YEARS. ___________IS PROVIDING PROFESSIONAL
 LIABILITY INSURANCE COVERING ALL SERVICES TO BE
 PERFORMED AS A PRIVATE PROVIDER.
 - PLEASE PROVIDE INSURANCE CERTIFICATE.
  
 3. QULIFICATIONS
 - PLEASE PROVIDE QUALIFICATIONS FOR REVIEWERS OR
 INSPECTORS WITH THEIR LICENSES.
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-04-13 Cont ID  
Sent By lbond Date 2023-04-13 Time 09:36 Rev Time 0.00
Received By lbond Date 2023-04-13 Time 09:36 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-03-31 Cont ID  
Sent By lbond Date 2023-03-31 Time 11:42 Rev Time 0.00
Received By lbond Date 2023-03-31 Time 11:42 Sent To  
Notes
***NONE***