Plan Review Details - Permit 23031011
| Plan Review Stops For Permit 23031011 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-20 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-20 |
Time |
07:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-04-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-03 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-03 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2023-04-03 13:03:49 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL4595.10-R6 MAXIMUM DESIGN PRESSURE -93.5 | | | PSF. DO NOT MEET THE MINIMUM ZONE 3 DESIGN PRESSURE | | | REQUIREMENT OF -102 FOR EXPOSURE CATEGORY C AREAS WITH | | | A GABLE ROOF; ROOF SLOPES 5/12-6/12 MEAN ROOF HEIGHT UP | | | TO 15 FT. SELECT SYSTEM THAT MEETS OR EXCEEDS THIS | | | REQUIREMENT. ALL APPLICABLE DETAILS AND ATTACHMENTS | | | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL | | | DRAWINGS. DETAILS AND ATTACHMENTS NOT SPECIFICALLY | | | COVERED IN PRODUCT APPROVALS WILL NEED SITE-SPECIFIC | | | ENGINEERING. SECOND REQUEST. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-20 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-20 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-20 |
Time |
08:07 |
Sent To |
|
|
| Notes |
| 2023-03-20 14:04:16 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL4595.10-R6 MAXIMUM DESIGN PRESSURE -93.5 | | | PSF. DO NOT MEET THE MINIMUM ZONE 3 DESIGN PRESSURE | | | REQUIREMENT OF -102 FOR EXPOSURE CATEGORY C AREAS WITH | | | A GABLE ROOF; ROOF SLOPES 5/12-6/12 MEAN ROOF HEIGHT UP | | | TO 15 FT. SELECT SYSTEM THAT MEETS OR EXCEEDS THIS | | | REQUIREMENT. ALL APPLICABLE DETAILS AND ATTACHMENTS | | | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL | | | DRAWINGS. DETAILS AND ATTACHMENTS NOT SPECIFICALLY | | | COVERED IN PRODUCT APPROVALS WILL NEED SITE-SPECIFIC | | | ENGINEERING. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-20 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-11 |
Time |
11:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-04-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-03 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-24 |
Time |
07:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-20 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-20 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-17 |
Time |
10:32 |
Sent To |
|
|
| Notes |
|
|
|