Plan Review Details - Permit 23030985
Plan Review Stops For Permit 23030985
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2023-04-20 Cont ID  
Sent By lbond Date 2023-04-20 Time 08:58 Rev Time 0.00
Received By lbond Date 2023-04-20 Time 08:58 Sent To  
Notes
2023-04-20 09:00:30PROVISO
  
 SETBACK FOR POOL EQUIPEMENT, POOL AND TERRACE MUST
 COMPLY WITH ZONING.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2023-06-09 Cont ID  
Sent By ppetty Date 2023-06-09 Time 08:45 Rev Time 0.00
Received By ppetty Date 2023-06-09 Time 08:45 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2023-06-05 Cont ID  
Sent By ppetty Date 2023-06-05 Time 10:52 Rev Time 0.00
Received By ppetty Date 2023-06-05 Time 09:51 Sent To  
Notes
2023-06-05 10:52:04CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2
 2. POOL EQUIPMENT NOT INCLUDED IN LOAD CALCULATION AND
 SERVICE SIZE NOT LISTED.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 SINCERELY,
  
 PHIL PETTY
 CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER
  
 561-805-6742
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2023-06-01 Cont ID  
Sent By ppetty Date 2023-06-01 Time 08:06 Rev Time 0.00
Received By ppetty Date 2023-06-01 Time 07:51 Sent To  
Notes
2023-06-01 08:15:46CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2
 2. POOL EQUIPMENT NOT INCLUDED IN LOAD CALCULATION AND
 SERVICE SIZE NOT LISTED.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 SINCERELY,
  
 PHIL PETTY
 CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER
  
 561-805-6742
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-04-17 Cont ID  
Sent By ppetty Date 2023-04-17 Time 11:35 Rev Time 0.00
Received By ppetty Date 2023-04-17 Time 11:24 Sent To  
Notes
2023-04-17 11:35:19CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020
 7TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1.PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE
 EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE
 IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 SINCERELY,
  
 PHIL PETTY
 CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER
  
 561-805-6742
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-06-09 Cont ID  
Sent By ppetty Date 2023-06-09 Time 08:46 Rev Time 0.00
Received By ppetty Date 2023-06-07 Time 08:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-06-05 Cont ID  
Sent By ppetty Date 2023-06-05 Time 10:52 Rev Time 0.00
Received By ppetty Date 2023-06-02 Time 10:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-06-01 Cont ID  
Sent By ppetty Date 2023-06-01 Time 08:16 Rev Time 0.00
Received By ppetty Date 2023-05-30 Time 17:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-05-03 Cont ID  
Sent By avolcy Date 2023-05-03 Time 14:18 Rev Time 0.00
Received By avolcy Date 2023-04-13 Time 13:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2023-04-19 Cont ID  
Sent By ccole Date 2023-04-19 Time 17:18 Rev Time 0.00
Received By ccole Date 2023-04-19 Time 17:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-04-17 Cont ID  
Sent By ppetty Date 2023-04-17 Time 12:53 Rev Time 0.00
Received By ppetty Date 2023-04-17 Time 12:53 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2023-05-03 Cont ID  
Sent By AVolcy Date 2023-05-03 Time 14:18 Rev Time 0.00
Received By avolcy Date 2023-05-03 Time 14:18 Sent To  
Notes
***NONE***