Plan Review Details - Permit 23030976
Plan Review Stops For Permit 23030976
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-04-11 Cont ID  
Sent By rmcdouga Date 2023-04-11 Time 14:44 Rev Time 0.00
Received By rmcdouga Date 2023-04-11 Time 14:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-04-05 Cont ID  
Sent By rmcdouga Date 2023-04-05 Time 14:06 Rev Time 0.00
Received By rmcdouga Date 2023-04-05 Time 14:06 Sent To  
Notes
2023-04-05 14:29:54PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SOME OF THE WORK THAT IS SPECIFIED FOR THIS PROJECT
 IS NOT IN SCOPE OF WORK THAT CAN BE DONE BY A PLUMBING
 CONTRACTOR. A FLORIDA LICENSED CBC OR CGC WILL HAVE TO
 APPLY FOR A SUB PERMIT FOR THIS PROJECT. FS 489
  
 2) THE VALUE SPECIFIED ON THE APPLICATION APPEARS TO BE
 LOW FOR THE SCOPE OF WORK. SUBMIT AN ITEMIZED COST
 BREAK DOWN FOR THE PROJECT. BUILDING PERMIT VALUATION.
 FOR PERMITTING PURPOSES, VALUATION OF FBC 109.3
 BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE
 TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL,
 INTERIOR FINISH, RELATIVE SITE WORK, ARCHITECTURAL AND
 DESIGN FEES, MARKETING COSTS, OVERHEAD AND PROFIT;
 EXCLUDING ONLY LAND VALUE. VALUATION REFERENCES MAY
 INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL
 CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT,
 MEANS, ETC.), AS PUBLISHED BY INTERNATIONAL CODE
 CONGRESS. FINAL BUILDING PERMIT VALUATION SHALL BE SET
 BY THE BUILDING OFFICIAL.
  
 3) SUBMIT COPIES OF THE ACTUAL TEST REPORTS FOR THE
 SOUND INSULATION INCLUDING FLAME SPREAD AND SMOKE
 DEVELOPED FOR THE APPLICABLE CONSTRUCTION CONDITIONS.
 THE TEST REPORTS SHALL BE FROM AN APPROVED TESTING
 AGENCY. THE FOLLOWING TEST REPORTS SRE EQUIRED:
  
 A) FBC 1207.2 AIR-BORNE SOUND. ASTM E 90-04
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 B) FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E 492-09
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 C) FBC 603.1 FLAME SPREAD - ASTM E 84-09
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-03-29 Cont ID  
Sent By rperdomo Date 2023-03-29 Time 15:43 Rev Time 0.00
Received By rperdomo Date 2023-03-29 Time 14:59 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-04-11 Cont ID  
Sent By   Date 2023-04-11 Time   Rev Time 0.00
Received By jcclark Date 2023-04-11 Time 07:38 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-03-30 Cont ID  
Sent By jcclark Date 2023-03-30 Time 07:16 Rev Time 0.00
Received By jcclark Date 2023-03-30 Time 07:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2023-04-21 Time   Rev Time 0.00
Received By amcgrego Date 2023-04-20 Time 08:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-04-11 Cont ID  
Sent By rmcdouga Date 2023-04-11 Time 14:44 Rev Time 0.00
Received By rmcdouga Date 2023-04-07 Time 10:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-04-05 Cont ID  
Sent By rmcdouga Date 2023-04-05 Time 14:30 Rev Time 0.00
Received By rmcdouga Date 2023-03-24 Time 11:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-04-21 Cont ID  
Sent By ccole Date 2023-04-21 Time 07:32 Rev Time 0.00
Received By ccole Date 2023-04-21 Time 07:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-04-10 Cont ID  
Sent By ccole Date 2023-04-10 Time 09:33 Rev Time 0.00
Received By ccole Date 2023-04-10 Time 09:13 Sent To  
Notes
2023-04-10 09:34:112ND REVIEW FBC-2020 PLUMBING
 PERMIT- 23030976
 4/10/2023
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. BASED ON THE
 CONTRACTOR???S PHONE CALL PLEASE PROVIDE A BASIC SITE
 PLAN THAT SHOWS THE LOCATION OF THE FACILITY ACCESSIBLE
 PUBLIC RESTROOMS. THE COMMENTS BELOW WERE NOT ADDRESSED
 IN A WRITTEN RESPONSE OR BY ANY CHANGES TO THE PLANS.
 PLEASE NOTE THE EXCEPTIONS IN THE FBC ACC WHICH ALLOW
 ALTERATIONS TO COMPLY TO THE MAXIMUM EXTENT INCLUDING
 SEC. 202.3 (2) TECHNICAL INFEASIBILITY AND 202.4.1
 DISPROPORTIONATE COST.
  
 1) THE OFFICE TOILET ROOM REMODEL APPEARS TO BE A LEVEL
 I ALTERATION BASED ON SEC. 602.1 FBC EX. LEVEL 1
 ALTERATIONS SHALL COMPLY WITH SEC. 705.1 FBC EX WHICH
 REFERENCES THE FBC ACCESSIBILITY. PLEASE SEE SECS.
 213.2- 213.3.7 FBC ACC AND PROVIDE DRAWINGS AND DETAILS
 SHOWING COMPLIANCE INCLUDING THE FOLLOWING ITEMS
 A) SEC. 603.2- 603.2.3: CLEARANCES.
 B) SEC. 603.3 MIRRORS.
 C) SEC. 604.1- 604.4: WATER CLOSET CLEAR FLOOR SPACE
 AND SEAT HEIGHT.
 D) SEC. 604.5- 604.5.2: GRAB BAR POSITIONING.
 E) SEC. 606.1- 606.5: LAVATORY CLEAR FLOOR SPACE, SINK
 HEIGHT, FAUCET CONTROLS, EXPOSED PIPE AND SURFACE
 PROTECTIONS.
  
 2) PLEASE NOTE ALL PLUMBING FIXTURES SHALL BE
 ACCESSIBLE. PROVIDE A FIXTURE SCHEDULE ON THE PLAN OR A
 NOTE VERIFYING COMPLIANCE- SEC. 404.1 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-03-27 Cont ID  
Sent By ccole Date 2023-03-27 Time 09:24 Rev Time 0.00
Received By ccole Date 2023-03-27 Time 09:16 Sent To  
Notes
2023-03-27 10:08:291ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23030976
 3/27/2023
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE OFFICE TOILET ROOM REMODEL APPEARS TO BE A LEVEL
 I ALTERATION BASED ON SEC. 602.1 FBC EX. LEVEL 1
 ALTERATIONS SHALL COMPLY WITH SEC. 705.1 FBC EX WHICH
 REFERENCES THE FBC ACCESSIBILITY. PLEASE SEE SECS.
 213.2- 213.3.7 FBC ACC AND PROVIDE DRAWINGS AND DETAILS
 SHOWING COMPLIANCE INCLUDING THE FOLLOWING ITEMS
 A) SEC. 603.2- 603.2.3: CLEARANCES.
 B) SEC. 603.3 MIRRORS.
 C) SEC. 604.1- 604.4: WATER CLOSET CLEAR FLOOR SPACE
 AND SEAT HEIGHT.
 D) SEC. 604.5- 604.5.2: GRAB BAR POSITIONING.
 E) SEC. 606.1- 606.5: LAVATORY CLEAR FLOOR SPACE, SINK
 HEIGHT, FAUCET CONTROLS, EXPOSED PIPE AND SURFACE
 PROTECTIONS.
  
 2) PLEASE NOTE ALL PLUMBING FIXTURES SHALL BE
 ACCESSIBILE. PROVIDE A FIXTURE SCHEDULE ON THE PLAN OR
 A NOTE VERIFYING COMPLIANCE- SEC. 404.1 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2023-04-05 Cont ID  
Sent By rmcdouga Date 2023-04-05 Time 14:30 Rev Time 0.00
Received By rmcdouga Date 2023-04-05 Time 14:30 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved