Plan Review Details - Permit 23030961
Plan Review Stops For Permit 23030961
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-03-28 Cont ID  
Sent By lbond Date 2023-03-28 Time 10:16 Rev Time 0.00
Received By lbond Date 2023-03-28 Time 10:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-23 Cont ID  
Sent By lbond Date 2023-03-23 Time 14:13 Rev Time 0.00
Received By lbond Date 2023-03-23 Time 14:13 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-03-27 Cont ID  
Sent By pleduc Date 2023-03-27 Time   Rev Time 0.00
Received By pleduc Date 2023-03-27 Time 11:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-03-17 Cont ID  
Sent By pleduc Date 2023-03-17 Time   Rev Time 0.00
Received By pleduc Date 2023-03-17 Time 11:18 Sent To  
Notes
2023-03-17 11:19:56THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS AN INDICATION OF THE SPEC SHEET FOR THE
 FLOOR UNDERLAYMENT, BUT NO SPEC SHEET NOR A PRODUCT
 NAME FOR THE ACTUAL PROPOSED LVT.
  
 LVT FLOORING IS MANUFACTURED AROUND THE WORLD BUT NOT
 ALL ARE TESTED AND MEETING LISTED AND NFPA STANDARDS.
  
 PER NFPA 101, CH 30
  
 30.3.3.3 INTERIOR FLOOR FINISH.
 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN
 ACCORDANCE WITH
 SECTION 10.2.
  
 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH
 10.2.2.2
 ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL
 HAVE A
 MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2.
  
 FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE LVT
 FLOORING NAME AND THE PRODUCT SPEC SHEETS INDICATING
 THE FIRE BEHAVIOR RATING.
  
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-28 Cont ID  
Sent By lbond Date 2023-03-28 Time 10:16 Rev Time 0.00
Received By lbond Date 2023-03-26 Time 07:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-23 Cont ID  
Sent By lbond Date 2023-03-23 Time 14:17 Rev Time 0.00
Received By lbond Date 2023-03-16 Time 10:17 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2023-03-23 Cont ID  
Sent By lbond Date 2023-03-23 Time 14:15 Rev Time 0.00
Received By lbond Date 2023-03-23 Time 14:15 Sent To  
Notes
***NONE***