| Plan Review Stops For Permit 23030921 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2023-07-21 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-07-21 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-07-21 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2023-07-21 09:49:31 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.3.4.1. SUBMIT ALL PRODUCT | | | APPROVALS/NOA???S THAT SHALL BE USED FOR THIS ROOFING | | | PROJECT TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST | | | BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | NOTE: MUST BE SIGNED BY ARCHITECT/ENGINEER BEFORE | | | SUBMITTING. REVIEW STAMP WITH INITIALS. FOURTH REQUEST. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-05-31 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-05-31 |
Time |
08:24 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-05-31 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2023-05-31 08:24:54 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.3.4.1. SUBMIT ALL PRODUCT | | | APPROVALS/NOA???S THAT SHALL BE USED FOR THIS ROOFING | | | PROJECT TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST | | | BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | NOTE: MUST BE SIGNED BY ARCHITECT/ENGINEER BEFORE | | | SUBMITTING. REVIEW STAMP WITH INITIALS. THIRD REQUEST. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-05-08 |
Time |
13:13 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-05-08 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2023-05-08 13:13:32 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1. APPROVED PLANS SHEET A-02 NORTH & | | | EAST ELEVATION DRAWING DETAILS SHOWS CLAY TILE ROOF & | | | AWNING OVERHANGS. PLEASE PROVIDE THE FOLLOWING FOR THE | | | TILE ROOF INSTALLATION; 2020 CODE VERSION PRODUCT | | | APPROVAL/ NOA???S FOR THE ROOF TILE SYSTEM; ROOF | | | UNDERLAYMENT SYSTEM; PROVIDE METHOD OF INSTALLATION, IF | | | USING ADHESIVE SET PROVIDE 2020 CODE VERSION PRODUCT | | | APPROVAL/ NOA???S. ALL APPLICABLE DETAILS AND | | | ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT | | | APPROVAL DRAWINGS. SECOND REQUEST. | | | 2. FBC B 107.3.4.1. SUBMIT ALL PRODUCT | | | APPROVALS/NOA???S THAT SHALL BE USED FOR THIS ROOFING | | | PROJECT TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST | | | BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | NOTE: MUST BE SIGNED BY ARCHITECT/ENGINEER BEFORE | | | SUBMITTING. REVIEW STAMP WITH INITIALS. SECOND REQUEST. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-31 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-31 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-31 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2023-03-31 09:18:00 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL2533-R28 SYSTEM NO. W-77 DOES NOT MEET THE | | | MINIMUM ZONE 3 DESIGN PRESSURE REQUIREMENT OF -108.17 | | | FOR EXPOSURE CATEGORY C AREAS. PROVIDE SYSTEM THAT | | | MEETS OR EXCEEDS ALL DESIGN PRESSURE REQUIREMENTS FOR | | | EXPOSURE CATEGORY C/PROVIDE SIGNED AND SEALED | | | ENGINEERED NAILING CALCULATIONS WITH AN APPROVED SYSTEM | | | 2. FBC B 107.2.1. APPROVED PLANS SHEET A-02 NORTH & | | | EAST ELEVATION DRAWING DETAILS SHOWS CLAY TILE ROOF & | | | AWNING OVERHANGS. PLEASE PROVIDE THE FOLLOWING FOR THE | | | TILE ROOF INSTALLATION; 2020 CODE VERSION PRODUCT | | | APPROVAL/ NOA???S FOR THE ROOF TILE SYSTEM; ROOF | | | UNDERLAYMENT SYSTEM; PROVIDE METHOD OF INSTALLATION, IF | | | USING ADHESIVE SET PROVIDE 2020 CODE VERSION PRODUCT | | | APPROVAL/ NOA???S. ALL APPLICABLE DETAILS AND | | | ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT | | | APPROVAL DRAWINGS. | | | 3. FBC B 107.3.4.1. SUBMIT ALL PRODUCT | | | APPROVALS/NOA???S THAT SHALL BE USED FOR THIS ROOFING | | | PROJECT TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST | | | BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | NOTE: MUST BE SIGNED BY ARCHITECT/ENGINEER BEFORE | | | SUBMITTING. REVIEW STAMP WITH INITIALS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
F |
Date |
2023-06-14 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-06-14 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-06-14 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2023-06-14 10:10:59 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | PROPERTY IS IN A HISTORIC DISTRICT, S TILE NOT | | | ARCHITECTURALLY APPROPRIATE. PLEASE REVISE TO BARREL | | | TILE AS SHOWN ON APPROVED PLANS. | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-05-12 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-05-12 |
Time |
14:54 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-05-12 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2023-05-12 14:55:29 | APPROVED ASSUMING THIS SCOPE OF WORK ONLY COVERS FLAT | | | ROOF PORTION OF PROJECT. IF TILED PORTIONS ARE ALSO | | | BEING CARRIED OUT HERE, NEED NOA FOR TRUE BARREL TILE. | | | THE TRUE BARREL TILE WILL NEED TO BE APPLIED PRIOR TO | | | THE COMPLETION OF THIS PROJECT, AS APPROVED BY THE | | | HISTORIC PRESERVATION BOARD. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-04-20 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-04-20 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2023-04-20 16:41:08 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | ARE TILE SECTIONS OF ROOF BEING AFFECTED? NEED DIAGRAM | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-07-18 |
Time |
08:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-06-15 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-06-15 |
Time |
07:14 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-05-16 |
Time |
16:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-15 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-05-15 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-05-03 |
Time |
08:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-04-21 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-04-21 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-03-29 |
Time |
15:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
N |
Date |
2023-04-21 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-04-21 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-04-21 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2023-04-21 08:14:07 | APPROVED UNDER MASTER 22110428 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-05-08 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-05-08 |
Time |
13:00 |
Sent To |
|
|
| Notes |
|
|