| Plan Review Stops For Permit 23030868 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2023-05-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-01 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-01 |
Time |
16:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2023-05-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-01 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-01 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2023-05-01 10:46:05 | SAME COMMENTS APPLY. SEE COPY BELOW. | | | | | | | | | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. SUBMITTED PRODUCT APPROVAL FL10497-R8 HAS BEEN | | | REVISED TO FL10497-R10. PLEASE PROVIDE THE FOLLOWING: | | | COVER PAGE, EVALUATION REPORT PAGES 1-4 AND | | | INSTALLATION INSTRUCTIONS FOR SYSTEM USED. ALL | | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER | | | RULE 61G20-3. THIRD REQUEST. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-04-26 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-26 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-26 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2023-04-26 12:58:48 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. SUBMITTED PRODUCT APPROVAL FL10497-R8 HAS BEEN | | | REVISED TO FL10497-R10. PLEASE PROVIDE THE FOLLOWING: | | | COVER PAGE, EVALUATION REPORT PAGES 1-4 AND | | | INSTALLATION INSTRUCTIONS FOR SYSTEM USED. ALL | | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER | | | RULE 61G20-3. THIRD REQUEST. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-04-18 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-18 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-18 |
Time |
13:32 |
Sent To |
|
|
| Notes |
| 2023-04-18 14:04:15 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. SUBMITTED PRODUCT APPROVAL FL10497-R8 HAS BEEN | | | REVISED TO FL10497-R9. PLEASE PROVIDE THE FOLLOWING: | | | INCLUDE COVER PAGE, EVALUATION REPORT PAGES 1-4 AND | | | INSTALLATION INSTRUCTIONS FOR SYSTEM USED. ALL | | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER | | | RULE 61G20-3. SECOND REQUEST. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-16 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-16 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-16 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2023-03-16 12:49:50 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. SUBMITTED PRODUCT APPROVAL FL10497-R8 HAS BEEN | | | REVISED TO FL10497-R9. PLEASE PROVIDE THE FOLLOWING: | | | INCLUDE COVER PAGE, EVALUATION REPORT PAGES 1-4 AND | | | INSTALLATION INSTRUCTIONS FOR SYSTEM USED. FLORIDA DBPR | | | PRODUCT APPROVAL FL10497-R8 SYSTEM NO. W-156 DO NOT | | | MEET THE MINIMUM ZONE 3 DESIGN PRESSURE REQUIREMENT OF | | | -108.17 FOR EXPOSURE CATEGORY C AREAS. PROVIDE SYSTEM | | | THAT MEETS OR EXCEEDS ALL DESIGN PRESSURE REQUIREMENTS | | | FOR EXPOSURE CATEGORY C/PROVIDE SIGNED AND SEALED | | | ENGINEERED NAILING CALCULATIONS WITH AN APPROVED | | | SYSTEM. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE | | | CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. | | | DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN | | | PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. | | | AS PER RULE 61G20-3. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-04-04 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-04-04 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-04-04 |
Time |
09:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-05-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-01 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-01 |
Time |
16:12 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-05-01 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-01 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-01 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-04-26 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-26 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-20 |
Time |
17:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-04-18 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-18 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-11 |
Time |
10:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-04-05 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-04-05 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-03-15 |
Time |
08:25 |
Sent To |
|
|
| Notes |
|
|