Plan Review Details - Permit 23030802
Plan Review Stops For Permit 23030802
Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status N Date 2023-04-19 Cont ID  
Sent By swelter Date 2023-04-19 Time 09:30 Rev Time 0.00
Received By hmoser Date 2023-05-09 Time 13:43 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-05-02 Cont ID  
Sent By rmcphers Date 2023-05-02 Time 15:33 Rev Time 0.00
Received By rmcphers Date 2023-05-02 Time 15:33 Sent To  
Notes
2023-05-02 15:33:41PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-05-02 Cont ID  
Sent By rmcphers Date 2023-05-02 Time 15:31 Rev Time 0.00
Received By rmcphers Date 2023-05-02 Time 14:10 Sent To  
Notes
2023-05-02 15:28:28RESTAURANT REMODEL AND ADDITION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE EXTERIOR WINDOWS, DOORS,
 LOUVERS AND ROOFING SYSTEMS - ALL PRODUCT APPROVALS
 NEED TO BE REVIEWED AND MARKED APPROVED BY THE BUILDING
 DESIGNER OF RECORD FBC 107.3.4
  
 2) PLEASE SHOW THE ACCESSIBLE BAR SEATING COUNTER
 HEIGHT, CLEAR FLOOR SPACE AND KNEE AND TOE CLEARANCE -
 FBC A 902
  
 3) PLEASE SHOW THE ACCESSIBLE SEATING, COUNTER HEIGHT,
 CLEAR FLOOR SPACE, KNEE AND TOE CLEARANCE AT THE "SUSHI
 BAR" - FBC A 902
  
 4) ACCESSIBLE RESTROOM = PLEASE USE THE WORDS
 "REFLECTIVE SURFACE" WHEN REFERRING TO THE MIRROR
 DIMENSIONS FROM THE FLOOR - FBC A 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
  
 5) PLEASE PROVIDE DETAILS FOR THE ROOF TOP EQUIPMENT
 SCREENING (SHOWING ALL ATTACHMENTS) - FBC 1609
  
 6) PLEASE SHOW THE ATTIC VENTILATION DETAILS - FBC
 1203.2 VENTILATION REQUIRED.
 ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE
 CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF
 FRAMING MEMBERS SHALL HAVE CROSS VENTILATION FOR EACH
 SEPARATE SPACE BY VENTILATION OPENINGS PROTECTED
 AGAINST THE ENTRANCE OF RAIN AND SNOW.
  
 7) PLEASE PROVIDE A BUILDING ONLY APPRAISAL FOR THIS
 BUILDING - NEEDED TO DETERMINE IF THE ADDITION AND
 REMODEL IS A SUBSTANTIAL IMPROVEMENT - FBC EXISTING
 BUILDING1103.5
  
 8) DRAWINGS A-12, A-13 AND A-14 DO NOT SHOW AS
 DIGITALLY SIGNED IN ADOBE READER - SIGNED AND SEALED
 DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-05-10 Cont ID  
Sent By jleahy Date 2023-05-10 Time 10:47 Rev Time 0.00
Received By jleahy Date 2023-05-10 Time 10:37 Sent To  
Notes
2023-05-10 14:25:22FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) PANEL CB AND CIRCUITS FED BY THAT PANEL 48,50,52
 WITHIN 6' OF THE SINK, 1,3 NOT SURE IF FED BY A
 RECPTACLE. TO BE GFCI PROTECTED. 210.8(B) NEXT TO SINK
 (6')
  
 2) PANEL CC CIRCUITS 13,14,15,17,19,23,25,32 ALSO NEED
 TO BE GFCI PROTECTED 210.8(B) OUTSIDE
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2023-04-14 Cont ID  
Sent By lquinone Date 2023-04-14 Time 15:18 Rev Time 0.00
Received By lquinone Date 2023-04-14 Time 15:18 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-04-10 Cont ID  
Sent By pleduc Date 2023-04-10 Time   Rev Time 0.00
Received By pleduc Date 2023-04-07 Time 10:57 Sent To  
Notes
2023-04-07 10:57:44FIRE PROVISO:
  
 MOVE EXIT SIGNS OVER THE PATH OF TRAVEL AND DOOR SWING
 WHERE INDICATED.
  
 SEE LIFE SAFETY PLAN.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-04-28 Cont ID  
Sent By ccole Date 2023-04-28 Time 14:36 Rev Time 0.00
Received By ccole Date 2023-04-28 Time 14:26 Sent To  
Notes
2023-04-28 14:37:181ST REVIEW FBC-2020 FUEL GAS
 PERMIT- 23030802
 4/28/23
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P-3: SHOW THE MEANS OF PROVIDING COMBUSTION
 AIR TO THE NEW GAS-FIRED COOKING APPLIANCES AND INCLUDE
 CALCULATIONS- SEC. 304.1 FBC FG.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-05-23 Cont ID  
Sent By aoliver Date 2023-05-23 Time 07:21 Rev Time 0.00
Received By aoliver Date 2023-04-06 Time 11:44 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-05-02 Cont ID  
Sent By rmcphers Date 2023-05-02 Time 15:31 Rev Time 0.00
Received By rmcphers Date 2023-05-02 Time 15:31 Sent To  
Notes
2023-05-02 15:32:53PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2023-05-10 Cont ID  
Sent By hmoser Date 2023-05-10 Time 12:39 Rev Time 0.00
Received By hmoser Date 2023-05-10 Time 11:18 Sent To  
Notes
2023-05-10 12:38:481) PROVIDE CFM ON BATHROOM EXHAUST FAN
 SECTION 107 SUBMITTAL DOCUMENTS
 WEST PALM BEACH AMENDMENTS.
 2) KITCHEN EXHAUST REQUIRERS SEPARATE APPLICATION
 PLANS AND PERMIT.
 3) ADDRESS ON APPLICATION AND PLAN DO NOT MATCH.
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By hmoser Date 2023-05-09 Time 13:43 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2023-05-02 Cont ID  
Sent By rmcphers Date 2023-05-02 Time 15:30 Rev Time 0.00
Received By rmcphers Date 2023-05-02 Time 15:30 Sent To  
Notes
2023-05-02 15:30:45SEE BUILDING PLAN REVIEW

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-04-28 Cont ID  
Sent By ccole Date 2023-04-28 Time 14:25 Rev Time 0.00
Received By ccole Date 2023-04-28 Time 12:29 Sent To  
Notes
2023-04-28 14:25:341ST REVIEW FBC-2020 PLUMBING
 PERMIT- 23030802
 4/28/23
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P-1 & P-3: DRAINAGE FROM HAND SINKS AND FLOOR
 SINKS BELOW ICE BINS AND ICE MAKERS SHALL NOT DISCHARGE
 INTO THE GREASE WASTE INTERCEPTOR- SEC. 1003.3.1 FBC P.
 THIS INCLUDES THE DRAINAGE FROM HAND SINKS AND FLOOR
 SINKS IN THE OUTDOOR BAR. PLEASE ROUT THE DRAINAGE TO
 THE SANITARY SEWER.
  
 2) P-1: PLEASE PROVIDE A SANITARY DRAINAGE AND VENT
 ISOMETRIC DRAWING- SEC. 107.3.5.1.3 WPB.
  
 3) P-2 & P-3: PROVIDE BACKFLOW PREVENTERS ON WATER
 SUPPLY LINES TO THE STEAMER, DISHWASHER, AND
 GLASSWASHER- SEC. 608.3 FBC P.
  
 4) P-2 & P-3: INDICATE THE MEANS OF PROVIDING TEMPERED
 WATER DELIVERY FROM THE LAVATORY SINKS AS REQUIRED BY
 SEC. 419.5 FBC P.
  
 5)P-2 & P-3: PLEASE VERIFY THERE IS AN EXISTING HOT
 WATER TEMPERATURE LIMITING DEVICE SUCH AS A MASTER
 THERMOSTATIC MIXING VALVE AT THE WATER HEATER, OR
 PROVIDE ONE IN COMPLIANCE WITH SEC. 607.1.1 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2023-05-02 Cont ID  
Sent By rmcphers Date 2023-05-02 Time 15:29 Rev Time 0.00
Received By rmcphers Date 2023-05-02 Time 15:29 Sent To  
Notes
2023-05-02 15:29:42SEE BUILDING PLAN REVIEW

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-05-02 Cont ID  
Sent By rmcphers Date 2023-05-02 Time 15:56 Rev Time 0.00
Received By rmcphers Date 2023-05-02 Time 15:54 Sent To  
Notes
2023-05-02 15:56:34SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS A-12, A-13, A-14, E-0, E-1, E-2-1, E-2,
 E-3, M-0, M-1-1, M-1, M-2, M-3, P-0, P-1-1, P-1, P-2,
 P-3 DO NOT SHOW AS DIGITALLY SIGNED IN ADOBE READER -
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).

Review Stop Z ZONING
Rev No 1 Status F Date 2023-05-22 Cont ID  
Sent By ESchneid Date 2023-05-22 Time 18:01 Rev Time 1.00
Received By eschneid Date 2023-05-22 Time 18:01 Sent To  
Notes
2023-05-22 18:03:08FAILED
  
 1) THIS PERMIT SHOWS AN INCREASE IN THE SIZE OF THE
 RESTAURANT BUILDING. THE MARINA DESIGN GUIDELINES
 STIPULATE THE FOLLOWING PROCESS THAT MUST BE APPROVED
 PRIOR TO THE EXPANSION OF ANY BUILDING WITHIN THE
 INTERIM MARINA PORTION OF THE DEVELOPMENT. PRIOR TO
 ZONING APPROVAL OF THIS PERMIT, A SITE PLAN REVIEW
 APPLICATION MUST BE APPROVED.
  
 PBA DEVELOPMENT THAT REQUIRES A MODIFICATION OF THE
 INTERIM MARINA MASTER PLAN SHALL SUBMIT A FSPR-III TO
 THE CITY AS OUTLINED IN THE SITE PLAN APPROVAL SECTION
 OF THESE DESIGN GUIDELINES ALONG WITH A SEPARATE,
 CONCURRENT FSPR-II APPLICATION TO THE CITY TO MODIFY
 THE INTERIM MARINA MASTER PLAN. ALL MODIFICATIONS TO
 THE INTERIM MARINA MASTER PLAN WHICH RESULT IN NO NET
 INCREASE TO ANY PROVISION OF THE INTERIM MARINA MASTER
 PLAN MAY BE MODIFIED THROUGH THE FSPR-II PROCESS.
 MODIFICATIONS TO THE INTERIM MARINA MASTER PLAN WHICH
 RESULT IN AN INCREASE OF ANY PROVISION OF THE INTERIM
 MARINA MASTER PLAN SHALL SUBMIT A FSPR-III APPLICATION
 TO THE CITY FOR APPROVAL.
  
 2) STAFF HAS NOTED THE FOLLOWING ITEMS THAT MUST BE
 ADDRESSED AS PART OF THE SITE PLAN REVIEW PROCESS.
  
 A. PROVIDE INFORMATION ON THE OVERALL TRAFFIC IMPACT OF
 THE ADDITIONAL SQUARE FOOTAGE VERSUS WHAT IS APPROVED
 FOR THE ESTABLISHED MASTER PLAN. THIS WILL AFFECT WHICH
 REVIEW PROCESS IS REQUIRED.
  
 B. THE BUILDING EXPANSION OCCURS IN AN AREA THE
 CURRENTLY CONTAINS LANDSCAPE (SPECIFICALLY A TERMINAL
 LANDSCAPE ISLAND). THE INTERIM MARINA MASTER PLAN IS
 APPROVED TO PERMIT A WAIVER THAT REDUCED THE MINIMUM
 REQUIRED LANDSCAPE TO FOR 12.9% OF THE INTERIM MARINA.
 THE APPROVED PLAN SHOWS THAT THIS MINIMUM IS CURRENTLY
 BEING MET, SO ANY ADDITIONAL REDUCTION IS NOT
 PERMITTED.
  
 C. THE BUILDING EXPANSION REMOVES AT LEAST TWO PARKING
 SPACES. THE INTERIM MARINA MASTER PLAN SHOWS THE SITE
 PROVIDES THE EXACT NUMBER OF SPACES THAT ARE REQUIRED.
 THE EXPANSION OF THE RESTAURANT REQUIRES ADDITIONAL
 PARKING SPACES AND WHEN COUPLED WITH THE REMOVAL OF
 PARKING, RESULTS IN A PARKING DEFICIENCY FOR THE
 INTERIM MARINA. NOTE: THE REMOVED TERMINAL ISLAND WOULD
 NEED TO BE REPLACED, WHICH REMOVE ADDITIONAL PARKING
 SPACES.
  
 D. THE PLANS MUST CLEARLY VERIFY THAT THE MAXIMUM
 MARINE INDUSTRIAL AND CREW AMENITIES DENSITIES LISTED
 IN THE MARINA DESIGN GUIDELINES ARE NOT EXCEEDED WITH
 THIS EXPANSION.
  
 E. A FULL REVIEW OF THE PLANS WILL BE PERFORMED AS PART
 OF THE SITE PLAN REVIEW.
  
 CONTACT ERIC SCHNEIDER @ 561-822-1446
 [email protected]
  
  