| 2023-03-13 08:09:20 | |
| | 1ST REVIEW FBC-2020 RES. GAS |
| | PERMIT- 23030670 |
| | 3/13/23 |
| | |
| | CODES IN EFFECT: |
| | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION |
| | 2020 |
| | FS- FLORIDA STATUTES |
| | FAC- FLORIDA ADMINISTRATIVE CODE |
| | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC |
| | |
| | PLAN REVIEW RESULTS: DENIED. |
| | |
| | 1) THERE IS NO INFORMATION IN THIS SUBMITTAL INCLUDING |
| | THE RISER, THE APPLICATION, THE SPECS OR THE CONTRACT |
| | TO INDICATE EXTERIOR OR INTERIOR TANKLESS WATER HEATER. |
| | IT IS ASSUMED TO BE AN EXTERIOR INSTALLATION. PLEASE |
| | CLARIFY AND PROVIDE A BASIC PLAN SHOWING THE LOCATION |
| | OF THE WATER HEATER AND REQUIRED EXHAUST CLEARANCES TO |
| | AIR INTAKE AND OPERABLE OPENINGS INTO THE HOUSE- SECS. |
| | G2427.2 & G2448.1 FBC RES. |
| | |
| | 2) GAS RISER: I WAS NOT ABLE TO LOCATE ANY PREVIOUS GAS |
| | PERMITS OR PLAN RECORDS AT THE RESIDENCE. PLEASE |
| | INDICATE "NEW" OR "EXISTING" VERIFY THE NEW WATER |
| | HEATER IS THE ONLY GAS APPLIANCE. IF THERE ARE OTHER |
| | EXISITNG GAS APPLIANCES PLEASE PROVIDE EITHER A |
| | COMPLETE RISER SHOWING THE EXISTING GAS APPLIANCES AND |
| | PIPING, OR NOTES AND/OR DETAILS VERIFYING THE |
| | ADDITIONAL LOAD WILL NOT IMPACT THE EXISTING GAS PIPING |
| | SYSTEM- SEC. G2412.3 FBC RES. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. |
| | |
| | CHRISTOPHER L. COLE |
| | MECHANICAL/PLUMBING PLANS EXAMINER |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH FL 33401 |
| | 561-805-6719 |
| | [email protected] |
| | |