Plan Review Details - Permit 23030639
Plan Review Stops For Permit 23030639
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2023-03-29 Cont ID  
Sent By jwitmer Date 2023-03-29 Time 14:48 Rev Time 0.00
Received By jwitmer Date 2023-03-29 Time 06:51 Sent To  
Notes
2023-03-29 14:48:49600 OKEECHOBEE BLVD THE HILTON CONVENTION CENTER HOTEL,
 NEW NO ASBESTOS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-06-06 Cont ID  
Sent By jwitmer Date 2023-06-06 Time 15:17 Rev Time 0.00
Received By jwitmer Date 2023-06-06 Time 14:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-29 Cont ID  
Sent By jwitmer Date 2023-03-29 Time 14:45 Rev Time 0.00
Received By jwitmer Date 2023-03-29 Time 06:52 Sent To  
Notes
2023-03-29 06:52:47WEST PALM BEACH DEVELOPMENT SERVICES
 BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 23030639
 ADD: 600 OKEECHOBEE BLVD./ HILTON CONVENTION CENTER
 HOTEL.
 CONT: SHAWMUT DESIGN & CONSTRUCTION
 TEL: 857-315-7956
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. MARCH 29TH/ 2023
 ACTION: DENIED
  
 1) SHEET A0.02 LIFE SAFETY SHEET OCCUPANCY ANALYSIS FOR
 THE FITNESS ROOM 101 USED THE BUSINESS OCCUPANCY
 CALCULATION AT 150 SQ. FT. VERSES EXERCISE ROOM AT 50
 GROSS TAKEN FROM TABLE 1004.5 2020 FBC-BUILDING CODE?
  
 2) SHEET A4.2.1 SHOWS A MILLWORK DETAIL WITH WATER
 COOLER. THE PLANS DO NOT INDICATE WHERE THE HIGH-LOW
 DRINKING FOUNTAINS ARE FOR THIS FLOOR AND TRAVEL
 DISTANCE (2902.5 FBC-BUILD) FROM THE FITNESS ROOM TO
 THE HIGH-LOW DRINKING FOUNTAINS, 2020 FBC-ACCESSIBILITY
 CODE. 211.2 MINIMUM NUMBER. NO FEWER THAN TWO DRINKING
 FOUNTAINS SHALL BE PROVIDED. ONE DRINKING FOUNTAIN
 SHALL COMPLY WITH 602.1 THROUGH 602.6 AND ONE DRINKING
 FOUNTAIN SHALL COMPLY WITH 602.7. SHOW DISTANCE IN THE
 KEY PLAN SHEET A0.01.
  
 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT
 REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE.
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-04-11 Cont ID  
Sent By rperdomo Date 2023-04-11 Time 14:19 Rev Time 0.00
Received By rperdomo Date 2023-04-11 Time 13:55 Sent To  
Notes
2023-04-11 14:19:01FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: PASS, SEE COMMENTS BELOW
  
 LOW VOLTAGE MUST BE SUBMITTED ON A SEPARATE PERMIT.
  
 END OF COMMENTS
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-05-08 Cont ID  
Sent By pleduc Date 2023-05-08 Time   Rev Time 0.00
Received By pleduc Date 2023-05-08 Time 15:43 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-03-20 Cont ID  
Sent By pleduc Date 2023-03-20 Time   Rev Time 0.00
Received By pleduc Date 2023-03-20 Time 11:29 Sent To  
Notes
2023-03-20 11:36:25THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) SHEET A 0.00 & A 0.02 - THERE ARE INDICATIONS OF A
 BUSINESS OCCUPANY, THE INDICATED SQ FT OF 1,385
 CONVERTS TO WELL OVER 50 PEOPLE USING BOTH 7/ OR 15/SQ
 FT FOR ASSEMBLY OCCUPANCY CALCULATIONS.
  
 PER NFPOA 1 CH 3 DEFINITIONS.
  
 3.3.196.2* ASSEMBLY OCCUPANCY. AN OCCUPANCY (1) USED
 FOR A
 GATHERING OF 50 OR MORE PERSONS FOR DELIBERATION,
 WORSHIP, ENTERTAIN MENT, EATING, DRINKING, AMUSEMENT,
 AWAITING TRANSPORTATION, OR SIMI LAR USES; OR (2) USED
 AS A SPECIAL AMUSEMENT BUILDING, REGARDLESS OF
 OCCUPANT LOAD.
  
 (12) GYMNASIUMS
  
 FOR THE OFFICIAL RECORD, PLEASE REVIEW AND PROVIDE THE
 CORRECT OCCUPANCY CLASSIFICATION & OCCUPANCY LOAD.
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-06-06 Cont ID  
Sent By jwitmer Date 2023-06-06 Time 15:17 Rev Time 0.00
Received By jwitmer Date 2023-05-05 Time 08:13 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-04-14 Cont ID  
Sent By medwards Date 2023-04-14 Time 11:19 Rev Time 0.00
Received By medwards Date 2023-03-17 Time 11:33 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2023-03-29 Cont ID  
Sent By jwitmer Date 2023-03-29 Time 14:46 Rev Time 0.00
Received By jwitmer Date 2023-03-29 Time 06:52 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2023-04-14 Cont ID  
Sent By medwards Date 2023-04-14 Time 11:18 Rev Time 0.00
Received By medwards Date 2023-04-14 Time 11:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-06-06 Cont ID  
Sent By jwitmer Date 2023-06-06 Time 15:17 Rev Time 0.00
Received By jwitmer Date 2023-06-06 Time 14:50 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-04-14 Cont ID  
Sent By medwards Date 2023-04-14 Time 11:19 Rev Time 0.00
Received By medwards Date 2023-04-14 Time 11:19 Sent To  
Notes
2023-03-29 14:50:28ARCHITECTURAL SHEETS ARE GOOD. 3/29/23 J WITMER