Plan Review Details - Permit 23030611
Plan Review Stops For Permit 23030611
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-07-07 Cont ID  
Sent By lbond Date 2023-07-07 Time 16:47 Rev Time 0.00
Received By lbond Date 2023-07-07 Time 16:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-17 Cont ID  
Sent By lbond Date 2023-03-17 Time 08:51 Rev Time 0.00
Received By lbond Date 2023-03-17 Time 08:50 Sent To  
Notes
2023-03-17 08:59:02BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 23030611
  
 REVIEWED: MARCH 17, 2023
  
 FLORIDA BUILDING CODE,7TH EDITION (2020)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC BUILDING
 FBC EXISTING BUILDING
  
 COMMENTS:
  
 AS PER SECTION 107.2.1
 PROVIDE SUPPORTING DOCUMENT FOR NOA OR FPA APPROVED FOR
 ALL NEW WINDOWS AND DOORS, PRESSURE CALCULATION
 ACCORDING TO ZONE "D"
 INDICATE ALL FLOOR ELEVATIONS ON EXISITING AND PROPOSED
 PLANS SAME FOR ALL ELEVATION AND SECTIONS THROUGHOUT
 THE SET OF DRAWINGS FOR ALL DISCIPLINES.
 SURVEY SHOULD BE DIGITALLY SIGNED AND SEALED- PLEASE
 INDICATE FLOOR ELEVATIONS ON SURVEY.
  
 IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT
 HESITATE TO CONTACT ME
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
  
 NOTES:
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-03-16 Cont ID  
Sent By mpeterso Date 2023-03-16 Time 13:12 Rev Time 0.00
Received By mpeterso Date 2023-03-16 Time 10:20 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2023-06-23 Cont ID  
Sent By ccole Date 2023-06-23 Time 15:56 Rev Time 0.00
Received By ccole Date 2023-06-23 Time 15:05 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-03-14 Cont ID  
Sent By ccole Date 2023-03-14 Time 11:28 Rev Time 0.00
Received By ccole Date 2023-03-14 Time 10:58 Sent To  
Notes
2023-03-14 11:28:441ST REVIEW FBC-2020 RES. GAS
 PERMIT- 23030611
 3/14/2023
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P-2.1: THE GAS RISER DRAWING IS INCOMPLETE,
 AND ALSO NEEDS CORRECTIONS. PLEASE PROVIDE THE
 FOLLOWING ITEMS.
 A) TOTAL DEVELOPED LENGTHS OF THE 2 PSI AND THE LOW
 PRESSURE PIPING SYSTEMS- SEC. G2413.4.1 FBC RES.
 B) GALV. PIPE SIZES FROM THE PRV OUTLETS TO THE
 GENERATOR AND POOL HEATER- SEC. G2413.3
 C) BASED ON THE LOW PRESSURE TABLE CALLED OUT- TABLE
 402.4(3) FBC FG- THE 3/4-INCH GALV. PIPE FROM THE PRV
 TO THE TEE FOR TWH-1 & 2 MUST BE INCREASED TO 1-INCH,
 AND THE 1/2-INCH BRANCHES FROM THE TEE TO THE WATER
 HEATERS SHALL BE INCREASED TO 3/4-INCH.
 D) PLACE NOTES TO INDICATE SEPARATE PERMITS ARE
 REQUIRED FOR THE GENERATOR AND THE POOL HEATER- SEC.
 107.2.1 WPB.
  
 2) P-2.1: SHOW THE CLEARANCE DISTANCE MEASUREMENTS FOR
 THE GAS WATER HEATER EXHAUST OUTLETS TO THE GAS WATER
 HEATER EXHAUST CLEARANCES FROM OPENINGS INTO THE
 BUILDING SUCH AS OPERABLE DOORS AND WINDOWS, AND OTHER
 AIR INTAKES SUCH AS SOFFIT VENTS- SEC. G2427.8 &
 G2448.1 FBC RES. PLEASE NOTE A MINIMUM OF 4FT.
 HORIZONTAL CLEARANCE IS TYPICALLY REQUIRED.
  
 3) P-2.1: PROVIDE COMBUSTION AIR CALCULATIONS FOR THE
 RANGE- SEC. G2407.1 FBC RES. PLEASE NOTE IF USING THE
 STANDARD METHOD OF INDOOR AIR VOLUME, A MINIMUM OF 7500
 CU. FT. IS REQUIRED.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2023-07-17 Cont ID  
Sent By fmittner Date 2023-07-17 Time 14:47 Rev Time 0.00
Received By fmittner Date 2023-07-17 Time 14:47 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2023-03-31 Cont ID  
Sent By fmittner Date 2023-03-31 Time 07:55 Rev Time 0.00
Received By fmittner Date 2023-03-31 Time 07:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-07-18 Cont ID  
Sent By aoliver Date 2023-07-18 Time 08:52 Rev Time 0.00
Received By aoliver Date 2023-06-22 Time 08:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-04-03 Cont ID  
Sent By jgomez Date 2023-04-03 Time 17:01 Rev Time 0.00
Received By jgomez Date 2023-03-13 Time 09:51 Sent To I
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2023-06-29 Cont ID  
Sent By hmoser Date 2023-06-29 Time 13:59 Rev Time 0.00
Received By hmoser Date 2023-06-29 Time 13:59 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-03-14 Cont ID  
Sent By medwards Date 2023-03-14 Time 08:18 Rev Time 0.00
Received By medwards Date 2023-03-14 Time 08:18 Sent To  
Notes
2023-03-14 08:18:281ST REVIEW FMC
 PERMIT: 23030611
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE GARAGE CONVERSION IS A CHANGE OF USE AND
 THEREFORE AN ENERGY CALCULATION IS REQUIRED. FEC
 R101.5.1.1.1
  
 2) IDENTIFY THE MECHANICAL SYSTEM ON THE FIRST FLOOR
 AND SHOW ITS LOCATION ON THE DRAWING. FBC 107.3.5
  
 3) SHOW THE OPERABLE WINDOW IN THE BATHROOM ON THE MAIN
 HOUSE 1ST FLOOR MEETS THE AGGREGATE AREA OF 3 SQUARE
 FEET TO EXEMPT AN EXHAUST FAN. FRC R303.3
  
 4) PROVIDE DETAILS FOR THE KITCHEN RANGE. IS THIS A
 BROILER COOKTOP? IS THERE TO BE A HOOD ABOVE THIS
 COOKTOP? IF SO, PROVIDE THE CFMS OF THE HOOD MOTOR. FRC
 M1503.4
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status P Date 2023-07-03 Cont ID  
Sent By rbrown Date 2023-07-03 Time 15:39 Rev Time 0.00
Received By rbrown Date 2023-07-03 Time 15:39 Sent To  
Notes
2023-07-03 15:44:02OK PROVIDED THE FLOOD BARRIER IS INSTALLED AT THE
 OPENINGS IN THE SITE WALL IN ACCORDANCE WITH THE
 SUBMITTED HAMMERHEAD ALUMINUM FLOOD PLANKS
 SPECIFICATION AND DETAILS IN ORDER TO MEET THE
 FOLLOWING REQUIREMENT SET BY THE CONSTRUCTION BOARD OF
 ADJUSTMENT AND APEALS (CBAA).
  
 AT THE CBAA MEETING ON 4/20/23, THE BOARD GRANTED THE
 APPLICANT'S APPEAL TO ALLOW THE STRUCTURE TO REMAIN AT
 THE CURRENT ELEVATION PROVIDED THE PROPERTY OWNER AND
 ARCHITECT PROVIDE FLOOD MITGATION MEASURES TO THE
 GREATEST EXTENT POSSIBLE WITHOUT LIFTING THE STRUCTURE.
 SUCH MEASURES WOULD INCLUDE A FLOOD BARRIER SITE WALL
 WITH FLOOD-PROOF BARRIERS AT THE GATES TO PREVENT
 INUNDATION WITH FLOOD WATER UP TO AN ELEVATION OF 8.0
 FEET NAVD WHICH IS 2.0 FEET ABOVE BASE FLOOD ELEVATION.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 ROBERT BROWN
 E-MAIL: [email protected]

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2023-04-20 Cont ID  
Sent By rbrown Date 2023-04-20 Time 15:55 Rev Time 0.00
Received By rbrown Date 2023-04-20 Time 15:55 Sent To  
Notes
2023-04-20 16:02:29STATUS UPDATE FROM PREVIOUS NFIP REVIEW.
  
 AT THE CONSTRUCTION BOARD OF ADJUSTMENT AND APEALS
 (CBAA) MEETING ON 4/20/23, THE BOARD GRANTED THE
 APPLICANT'S APPEAL TO ALLOW THE STRUCTURE TO REMAIN AT
 THE CURRENT ELEVATION PROVIDED THE PROPERTY OWNER AND
 ARCHITECT PROVIDE FLOOD MITGATION MEASURES TO THE
 GREATEST EXTENT POSSIBLE WITHOUT LIFTING THE STRUCTURE.
 SUCH MEASURES WOULD INCLUDE A FLOOD BARRIER SITE WALL
 WITH FLOOD-PROOF BARRIERS AT THE GATES TO PREVENT
 INUNDATION WITH FLOOD WATER UP TO AN ELEVATION OF 8.0
 FEET NAVD WHICH IS 2.0 FEET ABOVE BASE FLOOD ELEVATION.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 ROBERT BROWN
 E-MAIL: [email protected]

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2023-03-17 Cont ID  
Sent By dbattles Date 2023-03-17 Time 09:03 Rev Time 0.00
Received By dbattles Date 2023-03-17 Time 09:03 Sent To  
Notes
2023-03-17 09:26:48PROVIDE ELEVATION CERTIFICATE FOR EXISTING BUILDING.
 DYLAN BATTLES
 561-805-6718
 [email protected]
  
 THE PROPOSED WORK WOULD EXCEED THE THRESHOLD FOR
 SUBSTANTIAL IMPROVEMENT.
 SINCE THIS IS A CONTRIBUTING HISTORICAL PROPERTY YOU
 NAY APPLY FOR RELEF FROM OUR CONSTRUCTION BOARD OF
 ADJUSTMENT AND APPEALS.
 PLEASE CONTACT:
 KATHY PERRE
 PH: 561-805-6682
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-06-23 Cont ID  
Sent By ccole Date 2023-06-23 Time 15:55 Rev Time 0.00
Received By ccole Date 2023-06-23 Time 15:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2023-03-14 Cont ID  
Sent By ccole Date 2023-03-14 Time 10:54 Rev Time 0.00
Received By ccole Date 2023-03-14 Time 09:02 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-07-07 Cont ID  
Sent By lbond Date 2023-07-07 Time 16:40 Rev Time 0.00
Received By lbond Date 2023-07-07 Time 16:40 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-04-03 Cont ID  
Sent By jgomez Date 2023-04-03 Time 16:56 Rev Time 0.00
Received By jgomez Date 2023-04-03 Time 16:56 Sent To  
Notes
2023-04-03 16:57:19SIGNATURE REVIEW:
  
 1- DRAWING A-4 IS MISSING THE DIGITAL SIGNATURE AS
 REQUIRED BY CHAPTER 481 F.S. WHEN SUBMITTING
 DRAWINGS/DOCUMENTS FOR PUBLIC RECORDS. NEED TO SUBMIT
 DRAWINGS ELECTRONICALLY WITH VERIFIABLE DIGITAL
 SIGNATURE.
  
 ARCHITECTS
 61G1-16.005 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING AND FOR ELECTRONICALLY TRANSMITTING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status   Date 2023-03-16 Cont ID  
Sent By lbond Date 2023-03-16 Time 10:36 Rev Time 0.00
Received By lbond Date 2023-03-16 Time 10:36 Sent To  
Notes
2023-03-16 10:37:20ALL TRADES PASSED SIGNATURES-PASSED
2023-03-14 10:58:05PLUMBING AND GAS (P) PLANS PASSED/CC
2023-03-14 08:19:09MECHANICAL DIGITAL SIGNATURES APPROVED ME

Review Stop Z ZONING
Rev No 2 Status P Date 2023-07-17 Cont ID  
Sent By fmittner Date 2023-07-17 Time 14:47 Rev Time 0.00
Received By fmittner Date 2023-07-17 Time 14:47 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2023-03-31 Cont ID  
Sent By fmittner Date 2023-03-31 Time 07:55 Rev Time 0.00
Received By fmittner Date 2023-03-31 Time 07:55 Sent To  
Notes
2023-03-31 07:56:25REQUIRES SUBMITTAL OF SEPERATE LANDSCAPE PERMIT