| 2023-04-05 14:13:04 | JONATHAN BROOKS JR. |
| | BUILDING PLANS EXAMINER |
| | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| | PHONE (561) 805-6656 |
| | EMAIL: [email protected] |
| | |
| | 1ST REVIEW: FBC 2020 7TH EDITION |
| | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| | |
| | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R37 |
| | (HVHZ) IS NOT APPROVED FOR USE OUTSIDE HVHZ. CITY OF |
| | WEST PALM BEACH IS NOT LOCATED IN A HVHZ. YOU MIGHT |
| | CONSIDER USING FL5259-R37 (NON-HVHZ). |
| | 2. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R37 |
| | (NON- HVHZ) COVERS MULTIPLE PRODUCT TYPES; ROOF COVER |
| | OPTIONS; ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE |
| | COMBINATIONS, ALLOWABLE SUBSTRATES, ATTACHMENT |
| | LIMITATIONS & INSTALLATION APPROVED ASSEMBLIES. SELECT |
| | ATTACHMENT LIMITATION SYSTEM USED FROM 5.8.3.1 |
| | DIRECT-TO-DECK TABLE 4A: ALLOWABLE DESIGN PRESSURES, |
| | DIRECT-TO-DECK UNDERLAYMENT IN TILE ROOF APPLICATIONS |
| | PAGE #6 & 7 OR ATTACHMENT LIMITATION SYSTEM FROM |
| | 5.8.3.2 MECHANICALLY-ATTACHED BASE SHEET TABLE 4B |
| | ALLOWABLE DESIGN PRESSURES, 2-PLY UNDERLAYMENT SYSTEMS |
| | IN TILE ROOF APPLICATIONS PAGES #8-14. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |