Plan Review Details - Permit 23030575
Plan Review Stops For Permit 23030575
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status N Date 2023-04-11 Cont ID  
Sent By jwitmer Date 2023-04-11 Time 07:29 Rev Time 0.00
Received By jwitmer Date 2023-04-11 Time 07:17 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-04-04 Cont ID  
Sent By jwitmer Date 2023-04-04 Time 08:56 Rev Time 0.00
Received By jwitmer Date 2023-04-04 Time 08:22 Sent To  
Notes
2023-04-04 08:56:37 
 WEST PALM BEACH DEVELOPMENT SERVICES
 BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. REVISION: 23030575
 W. P. B. PERMIT: 22090229
 ADD: 1210 PALM BEACH LAKES BLVD.
 CONT: 87 CONSTRUCTION & ENGINEERING
 TEL: 786-247-1148
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. APRIL 04TH/ 2023
 ACTION: DENIED
  
 1) THIS REVISION: 23030575 IS STATED ON THE PLAN TO
 REMOVE AN EXISTING NONBEARING CMU WALL AND REPLACE THE
 WALL WITH NEW WOOD FRAMING. THE FLOOR PLAN DOES NOT
 STATE WHICH OF THE THREE WALLS THAT SURROUND THE TUB
 ARE THE NONBEARING CMU WALLS TO BE REMOVED. IN ALL
 CASES THERE IS AT LEAST ONE WALL ADJACENT TO THE TUB
 WHICH IS A TENANT SEPARATION WALL THAT REQUIRES
 COMPLIANCE WITH SECTION 420.2 DWELLING UNITS CONTIGUOUS
 TO THEM IN THE SAME BUILDING SHALL BE CONSTRUCTED AS
 FIRE PARTITIONS IN ACCORDANCE WITH SECTION 708. SECTION
 708.3 FIRE PARTITIONS SHALL HAVE A FIRE RESISTANCE
 RATING OF NOT LESS THAN 1 HOUR. PLEASE PROVIDE EITHER
 THE UL LISTING AND ASSEMBLY OR GYPSUM ASSOCIATION FIRE
 ASSEMBLY.
  
 2) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT
 REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE.
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-04-07 Cont ID  
Sent By rperdomo Date 2023-04-07 Time 14:37 Rev Time 0.00
Received By rperdomo Date 2023-04-07 Time 14:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-03-29 Cont ID  
Sent By rperdomo Date 2023-03-29 Time 08:38 Rev Time 0.00
Received By rperdomo Date 2023-03-29 Time 08:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-04-05 Cont ID  
Sent By cwalker Date 2023-04-05 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2023-04-05 09:26:13FIRE PROVISO COMMENT:
  
 ENSURE FIRE RATED TENANT SEPARATION WALLS ARE REPAIRED
 TO THE EXISTING FIRE RATED SEPARATION.
  
 C. WALKER
  
 561-804-4762
  
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-04-04 Cont ID  
Sent By cwalker Date 2023-04-04 Time   Rev Time 0.00
Received By cwalker Date 2023-04-04 Time   Sent To  
Notes
2023-04-04 09:24:27FIRE PROVISO COMMENT:
  
 ENSURE FIRE RATED TENANT SEPARATION WALLS ARE REPAIRED
 TO THE EXISTING FIRE RATED SEPARATION.
  
 C. WALKER
  
 561-804-4762
  
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-04-11 Cont ID  
Sent By jwitmer Date 2023-04-11 Time 07:30 Rev Time 0.00
Received By jwitmer Date 2023-04-04 Time 13:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-04-04 Cont ID  
Sent By lmarchan Date 2023-04-04 Time 10:33 Rev Time 0.00
Received By lmarchan Date 2023-03-14 Time 11:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2023-04-03 Cont ID  
Sent By jgomez Date 2023-04-03 Time 10:01 Rev Time 0.00
Received By jgomez Date 2023-04-03 Time 10:01 Sent To  
Notes
2023-04-03 10:01:58NO ARCHITECT OR ENGINEER PLAN. JG.


Account Summary | Usage Policy | Privacy Policy