| Plan Review Stops For Permit 23030435 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-07-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-21 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-21 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2023-07-21 15:55:07 | CONCRETE FENCE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE WIND DESIGN DATA ON DRAWING C2 SHOWS RISK | | | CATEGORY II WITH WIND SPEED AT 145MPH - WIND SPEED | | | NEEDS TO BE 150MPH FOR A RISK CATEGORY I AND 170MPH FOR | | | A RISK CATEGORY II SEE FBC WPB SECTION 120 | | | | | | 2) THE FOUNDATIONS ARE SHOWN FOR THE COLUMNS - PLEASE | | | SHOW THE FOUNDATION FOR THE BLOCK WALL IN BETWEEN THE | | | COLUMNS - FBC WPB 107.2.1 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-08 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-08 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2023-06-08 15:34:38 | CONCRETE FENCE | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE WIND DESIGN DATA ON DRAWING C2 SHOWS RISK | | | CATEGORY II WITH WIND SPEED AT 145MPH - WIND SPEED | | | NEEDS TO BE 150MPH FOR A RISK CATEGORY I AND 170MPH FOR | | | A RISK CATEGORY II SEE FBC WPB SECTION 120 | | | | | | 2) THE FOUNDATIONS ARE SHOWN FOR THE COLUMNS - PLEASE | | | SHOW THE FOUNDATION FOR THE BLOCK WALL IN BETWEEN THE | | | COLUMNS - FBC WPB 107.2.1 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-07-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-07-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-07-21 |
Time |
10:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2023-05-23 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-05-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-05-23 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2023-05-23 10:48:04 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS AN INDICATION OF A 6FT BRICK FENCE WALL | | | THAT APPEARS TO BEGIN AT THE APT COMPLEX ENTRY/EXIT | | | POINT, HOWEVER, THERE IS NO INDICATION OF THE DIMENSION | | | OF THE WIDTH OF THE OPENING AT THAT ENTRY /EXIT POINT. | | | | | | FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE SPECIFIC | | | DIMENSION AND/OR THE SPECIFIC LOCATION OF WHERE THE | | | FENCE WALL BEGINS ON EACH SIDE OF THE ENTRY/EXIT POINT. | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-07-20 |
Time |
14:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-06-14 |
|
|
Cont ID |
|
| Sent By |
lngelman |
Date |
2023-06-14 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
lngelman |
Date |
2023-05-19 |
Time |
16:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-07-21 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-07-21 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-07-21 |
Time |
15:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-08 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-08 |
Time |
15:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-06-14 |
|
|
Cont ID |
|
| Sent By |
lgelman |
Date |
2023-06-14 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
lngelman |
Date |
2023-06-14 |
Time |
12:37 |
Sent To |
|
|
| Notes |
| 2023-06-14 12:44:40 | SUBMITTED PLANS ARE NOT SUFFICIENT FOR ZONING REVIEW, | | | LOCATION OF BRICK WALL SHOULD BE REFERENCED WITH A | | | THICKER LINE TO DIFFERENTIATE FROM SETBACKS, RIGHT OF | | | WAY, PROPERTY LINES AN SECURITY FENCE. PROVIDED PLANS | | | HAVE TOO MANY LINES THAT OVERLAP AND NEED TO BE | | | LEGIBLE. | | | | | | WALLS OR FENCES MUST CLEAR ALL EASEMENTS OF RECORDS. | | | PROVIDE EASEMENT CONSENT FORM IF FENCING/WALLS ENCROACH | | | ONTO UTILITY EASEMENT ON SOUTH PROPERTY LINE. | | | | | | **** | | | REVIEWED BY | | | | | | LINDSEY GELMAN | | | 561-822-1275 | | | [email protected] |
|
|