Plan Review Details - Permit 23030381
Plan Review Stops For Permit 23030381
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2023-05-17 Cont ID  
Sent By cpuell Date 2023-05-17 Time 10:12 Rev Time 0.00
Received By cpuell Date 2023-05-17 Time 10:12 Sent To  
Notes
2023-05-17 10:14:36PARCEL READDRESSED, PRIMARY WILL BE 860 N RAILROAD AVE,
 ADDITIONAL TENANT SPACES ARE 870, 880 AND 890 N
 RAILROAD AVE.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2023-03-23 Cont ID  
Sent By cpuell Date 2023-03-23 Time 10:30 Rev Time 0.00
Received By cpuell Date 2023-03-23 Time 10:30 Sent To  
Notes
2023-03-23 10:38:37WORKING WITH DAMIEN BARR ON READDRESSING BUILDING.
 PLEASE CONTACT DS_ADDRESSING @WPB.ORG OR CALL
 561-805-6659

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status P Date 2023-03-10 Cont ID  
Sent By swelter Date 2023-03-10 Time 13:05 Rev Time  
Received By swelter Date   Time   Sent To  
Notes
2023-03-10 13:06:24SEE MASTER PERMIT# 22120561

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-07-07 Cont ID  
Sent By rmcphers Date 2023-07-07 Time 12:53 Rev Time 0.00
Received By rmcphers Date 2023-07-07 Time 11:52 Sent To  
Notes
2023-07-07 11:59:47NEW COMMERCIAL BUILDING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) THE BUILDING PLACEMENT ON THE SITE SHOWN ON DRAWING
 T-100 & A.100 DO NOT MATCH - 8TH STREET IS SHOWN ON THE
 SOUTH SIDE OF DRAWING T-100 AND ON THE NORTH SIDE OF
 A-100 - PLEASE CLARIFY.
  
 2) SINCE 8TH STREET IS NOT SHOWN ON THE SOUTH SIDE ON
 DRAWING A-100 - PLEASE SHOW THE SOUTH EXTERIOR WALL
 WHICH IS 5"5" FROM THE PROPERTY LINES TO BE 1 HOUR FIRE
 RATED FBC TABLE 602
  
 3) PLEASE SHOW THE SOUTH EXTERIOR WALL OPENING
 CALCULATIONS BASED ON FBC TABLE 705.8
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-05-15 Cont ID  
Sent By rmcphers Date 2023-05-15 Time 13:44 Rev Time 0.00
Received By rmcphers Date 2023-05-15 Time 13:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-23 Cont ID  
Sent By rmcphers Date 2023-03-23 Time 14:48 Rev Time 0.00
Received By rmcphers Date 2023-03-23 Time 09:40 Sent To  
Notes
2023-03-23 14:48:28NEW COMMERCIAL BUILDING
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE BUILDING SET BACKS FROM THE PROPERTY
 LINES - FBC WPB 107.2.5
  
 2) PLEASE SHOW THE STORM WATER FLOW AWAY FROM THE
 BUILDING AND AWAY FROM THE ADJACENT PROPERTY ON THE
 SITE PLAN OR PROVIDE A STORM WATER DRAINAGE PLAN - FBC
 WPB 107.2.5
  
 3) EXTERIOR DOORS - FBC 3202.2ENCROACHMENTS ABOVE GRADE
 AND BELOW 8 FEET IN HEIGHT. DOORS AND WINDOWS SHALL NOT
 OPEN OR PROJECT INTO THE PUBLIC RIGHT-OF-WAY.
  
 4) FLOOR PLAN AND LIFE SAFETY PLAN - THE FIRE RATED
 ELEVATOR LOBBY AND CORRIDOR SEEMS NOT TO BE COMPLETE AT
 HALL (107), MAIL BOX ROOM (115) AND TRASH ROOM (104)
 ALONG WITH THE DOORS TO SUCH - PLEASE CLARIFY IF THE
 FIRE WALL IS TO BE CONTINUOUS.
  
 5) DRAWING A.501 SHOWS THE HANDRAIL EXTENSIONS AT THE
 TOP LANDING TO TURN - HAND RAILS EXTENSIONS SHOULD NOT
 TURN UNLESS THE STAIR CONTINUES - FBC 1014.6 WHERE
 HANDRAILS ARE NOT CONTINUOUS BETWEEN FLIGHTS, THE
 HANDRAILS SHALL EXTEND HORIZONTALLY NOT LESS THAN 12
 INCHES (305 MM) BEYOND THE TOP RISER AND CONTINUE TO
 SLOPE FOR THE DEPTH OF ONE TREAD BEYOND THE BOTTOM
 RISER.
  
 6) DRAWING A.501 PLYWOOD SHOWN ON THE EXTERIOR WALL
 SHOULD BE SHOWN AS FIRE RETARDANT PER FBC 603.1
  
 7) PLEASE PROVIDE DETAILS FOR THE EXTERIOR WALL TILE
 CLADDING - ATTACHMENTS SIZE, TYPE AND ON CENTER
 SPACING, FRAMING ATTACHMENTS, WALL SHEATHING
 ATTACHMENTS ETC. - OR PROVIDE PRODUCT APPROVALS -
 EXTERIOR CLADDING IS SUBJECT TO WIND LOADS - FBC 1609.1
  
 8) PLEASE PROVIDE A SURVEY FBC WPB 107.1

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-07-13 Cont ID  
Sent By jleahy Date 2023-07-13 Time 16:43 Rev Time 0.00
Received By jleahy Date 2023-07-13 Time 16:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2023-03-16 Cont ID  
Sent By jleahy Date 2023-03-16 Time 18:27 Rev Time 0.00
Received By jleahy Date 2023-03-16 Time 17:10 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2023-07-13 Cont ID  
Sent By cseifer Date 2023-07-13 Time 08:24 Rev Time 0.00
Received By cseifer Date 2023-07-13 Time 08:24 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2023-05-15 Cont ID  
Sent By lquinone Date 2023-05-15 Time 10:58 Rev Time 0.00
Received By lquinone Date 2023-05-15 Time 10:58 Sent To  
Notes
2023-05-15 10:58:53 
 PROJECT UNDER FORMAL ENGINEERING REVIEW.
  
 THANKS,
 LINDA M. QUINONES-CINTRON, PROJECT COORDINATOR,
 ENGINEERING SERVICES DEPARTMENT (561) 494-1085
 [email protected]
 FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2023-03-13 Cont ID  
Sent By rrossano Date 2023-03-13 Time   Rev Time  
Received By rrossano Date 2023-03-13 Time   Sent To  
Notes
2023-03-13 10:08:29UNDER FORMAL ENGINEERING REVIEW.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2023-07-10 Cont ID  
Sent By pleduc Date 2023-07-10 Time   Rev Time 0.00
Received By pleduc Date 2023-07-10 Time 13:33 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-05-15 Cont ID  
Sent By pleduc Date 2023-05-15 Time   Rev Time 0.00
Received By pleduc Date 2023-05-15 Time 11:53 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2023-03-08 Cont ID  
Sent By pleduc Date 2023-03-08 Time   Rev Time 0.00
Received By pleduc Date 2023-03-07 Time 10:13 Sent To  
Notes
2023-03-08 14:41:15THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) SHEET LS 102 - THERE IS NO INDICATION OF AN AREA OF
 REFUGE.
  
 PER NFPA 101 CH 38, NEW BUSINESS
  
 38.2.2.12 AREAS OF REFUGE.
 38.2.2.12.1 AREAS OF REFUGE COMPLYING WITH 7.2.12 SHALL
 BE
 PERMITTED
  
 AREAS ACCESSIBLE TO PERSONS WITH SEVERE MOBILITY
 IMPAIRMENT IN NEW
 BUILDINGS MUST BE PROVIDED WITH ACCESSIBLE MEANS OF
 EGRESS IN
 ACCORDANCE WITH 7.5.4.1.
  
 THE PROVISION OF 38.2.2.12.2 PERMITS A SPRINKLERED
 STORY
 OF A BUSINESS OCCUPANCY BUILDING TO BE CONSIDERED AN
 AREA OF
 REFUGE, EVEN IF AN OCCUPANT DOES NOT HAVE ACCESS TO ANY
 OF THE
 TENANT SPACES. THE EFFECTIVENESS OF SPRINKLER SYSTEMS
 SHOULD
 ALLOW AN OCCUPANT WITH MOBILITY IMPAIRMENT TO REMAIN ON
 THE
 FLOOR OF FIRE ORIGIN WITHOUT EXPERIENCING UNTENABLE
 CONDITIONS.
 DOORS TO TENANT SPACES THAT ARE LOCKED CREATE
 INACCESSIBILITY TO
 SPACES OTHER THAN THE CORRIDOR, SO THE CORRIDOR
 EFFECTIVELY SERVES
 AS THE AREA OF REFUGE, EVEN THOUGH IT DOES NOT
 NECESSARILY MEET
 THE DETAILED REQUIREMENTS OF 7.2.12
  
 PLEASE REVIEW AND PROVIDE PER THE REQUIREMENTS.
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2023-05-17 Cont ID  
Sent By ccole Date 2023-05-17 Time 14:34 Rev Time 0.00
Received By ccole Date 2023-05-17 Time 11:19 Sent To  
Notes
2023-05-17 14:35:02GAS SHALL BE UNDER A SEPARATE PERMIT PER THE ENGINEER'S
 REQUEST.

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-03-09 Cont ID  
Sent By ccole Date 2023-03-09 Time 11:53 Rev Time 0.00
Received By ccole Date 2023-03-09 Time 11:38 Sent To  
Notes
2023-03-09 11:53:371ST REVIEW FBC-2020 FUEL GAS
 PERMIT- 23030381
 3/9/23
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P-100 & P-500: THE GAS METER DETAIL SHOWS
 PIPING TO BE RUN THROUGH THE TENANT SPACES. PLEASE SHOW
 THE PIPING RUNS ON P-100 & P-200 AND PROVIDE A GAS
 RISER DRAWING- SEC. 107.3.5.1.5 WPB. THE RISER SHALL
 SHOW:
 A) DELIVERY PRESSURE AT THE METER.
 B) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 (CAN BE NOTED AS FUTURE).
 C) TYPES AND SIZES OF PIPING.
 D) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 E) BRANCH AND CUT PIPE LENGTH MEASUREMENTS.
 F) LOCATIONS OF REGULATORS, SHUTOFF VALVES.
 G) OUTLET PRESSURES AT MP REGULATORS.
 H) LOCATIONS AND TYPES OF PIPE SLEEVES AND PIPE CAPS.
 I) PIPE SIZING TABLES.
  
 2) PLEASE NOTE REQUIRED COMBUSTION AIR AND VENTING
 PLANS AND SPECIFICATIONS FOR APPLIANCES IF NOT PROVIDED
 AT THIS TIME CAN BE LISTED ON THE PLANS AS ???FUTURE TO
 BE PROVIDED UNDER SEPARATE PERMITS???
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By amcgrego Date 2023-07-05 Time 08:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-06-05 Cont ID  
Sent By hmoser Date 2023-06-05 Time 11:28 Rev Time 0.00
Received By hmoser Date 2023-05-12 Time 08:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-23 Cont ID  
Sent By rmcphers Date 2023-03-23 Time 15:03 Rev Time 0.00
Received By rmcphers Date 2023-03-06 Time 10:10 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-03-23 Cont ID  
Sent By rmcphers Date 2023-03-23 Time 14:48 Rev Time 0.00
Received By rmcphers Date 2023-03-23 Time 14:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2023-07-17 Cont ID  
Sent By jbaker Date 2023-07-17 Time 12:02 Rev Time 0.00
Received By jbaker Date 2023-07-17 Time 12:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2023-06-05 Cont ID  
Sent By hmoser Date 2023-06-05 Time 11:06 Rev Time 0.00
Received By hmoser Date 2023-06-05 Time 10:26 Sent To  
Notes
2023-06-05 11:11:35PLAN DENIED
 1) PROVIDE EQUIPMENT SCHEDULE ON PLAN.
 FBC 107.3.5.
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-03-10 Cont ID  
Sent By medwards Date 2023-03-10 Time 06:16 Rev Time 0.00
Received By medwards Date 2023-03-10 Time 06:15 Sent To  
Notes
2023-03-10 06:16:171ST REVIEW FMC
 PERMIT: 23030381
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE THE ENERGY CALCULATIONS FOR THIS PROJECT.
 FEC C402.1
  
 2) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS
 FOR THIS PROJECT. FEC C403.2.1
  
 3) SHOW THAT ALL ROOFTOP EQUIPMENT WILL HAVE THE
 REQUIRED CLEARANCE FROM THE ROOFS EDGE OR PROVIDE
 GUARDS. FMC 304.11
  
 4) THE LIFE SAFETY SHEET INDICATES RATED WALLS. SHOW
 HOW THE PENETRATIONS MADE BY THE MECHANICAL DUCTWORK
 WILL BE PROTECTED. FMC 607.5.2
  
 5) PROVIDE DUCT SMOKE DETECTORS IN ALL MECHANICAL
 SYSTEMS THAT MEET THE REQUIREMENTS OF FMC 606.2
  
 6) PROVIDE A SPEC SHEET FOR THE MECHANICAL EQUIPMENT
 SHOWN ON THE MECHANICAL DRAWINGS. FBC 107.3.5
  
 7) ADD A NOTE ON THE MECHANICAL DRAWINGS STATING THAT
 THE DUCTWORK FOR FUTURE USE MAY BE REVISED AT TENANT
 UPFIT.
  
 8) SHOW THAT ALL EXHAUST TERMINATIONS MEET THE DISTANCE
 REQUIREMENTS OF FMC 501.3
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-07-07 Cont ID  
Sent By ccole Date 2023-07-07 Time 10:13 Rev Time 0.00
Received By ccole Date 2023-07-07 Time 08:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-05-17 Cont ID  
Sent By ccole Date 2023-05-17 Time 14:32 Rev Time 0.00
Received By ccole Date 2023-05-17 Time 11:19 Sent To  
Notes
2023-05-17 14:34:072ND REVIEW FBC-2020 PLUMBING
 PERMIT-23030381
 5/17/2023
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. PLAN REVIEW RESULTS:
 DENIED. FAILED 1ST REVIEW COMMENTS #1, 2, 6A, 9, & 11
 ARE LISTED BELOW WITH ADDITIONAL NOTES.
  
 1) FAILED. SHEET P100- IMPORTANT NOTE: SEPARATE PERMITS
 ARE REQUIRED FOR THE POTABLE WATER SERVICE BACKFLOW
 PREVENTER AND THE GREASE INTERCEPTOR, AND PERMIT
 APPLICATIONS FOR EACH SHALL BE SUBMITTED PRIOR TO
 APPROVAL OF THE MAIN PLUMBING PLANS FOR THE PROJECT.
 YOU CAN SUBMIT APPLICATIONS TBD (TO BE DETERMINED) IF
 YOU DO NOT HAVE CONTRACTORS SELECTED BY EMAILING
 COMPLETED PERMIT APPLICATIONS TO
 [email protected] . YOU WILL RECEIVE INSTRUCTIONS
 TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND
 PAY FEES AT A FUTURE DATE, BUT THE APPLICATIONS ARE
 REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES
 AND UPLOAD PLANS AT THE SAME TIME. AFTER YOU HAVE THE
 PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL AND I WILL
 CHANGE THE REVIEW STATUS TO PASS.
  
 THE ARCHITECT'S COMMENT RESPONSE NARRATIVE STATES THE
 BACKFLOW AND GREASE INTERCEPTOR ARE INLCLUDED IN A
 STREET IMPROVEMENT PERMIT HOWEVER AS STATED BELOW
 SEPARATE BUILDING DEPARTMENT PERMITS ARE REQUIRED.
  
 2) FAILED. P-100 & P-200: PROVIDE PLUMBING FIXTURE
 CALCULATIONS FOR THE NEW BUILDING IN ACCORDANCE WITH
 TABLE 403.1 FBC P. PROVIDE SCHEDULES THAT SHOW THE
 REQUIRED AND PROVIDED NUMBER OF FIXTURES FOR EACH
 SEPARATE OCCUPANCY OR TENANT SPACE. THE CALCULATIONS
 SHALL CLARIFY WHICH TENANT SPACES WILL ARE BEING
 SERVICED BY THE NEW GANG BATHROOMS, DRINKING FOUNTAINS
 AND JANITOR???S SINK.
 NO CALCULATIONS PROVIDED. THE ENGINEER???S RESPONSE
 NARRATIVE STATES THE INDOOR RESTROOMS ARE FOR THE
 OUTDOOR SPACES WHICH ARE NOT SHOWN ON THE PLANS AND NOT
 INCLUDED IN THE OCCUPANT LOAD CALCULATIONS ON SHEET
 T.100. PLEASE COMPLY WITH THE COMMENT.
  
  
 6) FAILED ITEM A BELOW. P-700: THE SANITARY RISER
 APPEARS TO SHOW IMPROPER WET-VENTING FOR THE MEN???S
 AND WOMEN???S BATHROOM FIXTURES PER ITEMS A-D BELOW.
  
 A) FAILED. URINALS ARE NOT INCLUDED IN THE DEFINITION
 OF A BATHROOM GROUP SO THEIR FIXTURE DRAINS SHALL NOT
 CONNECT TO THE WET VENT, AND THEIR DRY VENTS SHALL NOT
 BE THE DRY VENT FOR THE SYSTEM- SECS. 202 & 912.1 FBC
 P. IN ORDER TO FIX THE BRANCH, THE URINAL DRAINS SHALL
 CONNECT DOWNSTREAM OF THE L2/WC-1 WET VENT, AND A
 COMMON VENT OR INDIVIDUAL VENTS FOR THE URINALS SHALL
 BE PROVIDED- SECS. 910.1 & 911.1.
 TO MEET THE CODE PLEASE PROVIDE INDIVIDUAL VENTS FOR
 THE URINALS.
  
 9) FAILED. P-700: TEMPERED WATER SHALL BE DELIVERED
 FROM THE LAVATORIES THROUGH A WATER TEMPERATURE
 LIMITING DEVICE THAT CONFORMS TO ASSE 1070- SECS. 419.5
 & 607.1.2 FBC P.
 NOT PROVIDED.
  
 11) FAILED. P-500: PLEASE PROVIDE A WATER HEATER DETAIL
 THAT SHOW THE PIPING CONNECTIONS TO THE RECIRCULATION
 PUMP, REQUIRED EXPANSION TANK AND THE REQUIRED MASTER
 THERMOSTATIC MIXING VALVE- SECS. 607.2.2 & 607.3 FBC P.
 PLEASE NOTE THE MASTER MIXING VALVE IS REQUIRED BECAUSE
 THE THERMOSTAT ON THE WATER HEATER CANNOT BE THE
 TEMPERATURE LIMITING MEANS FOR THE HOT WATER SYSTEM-
 SEC. 607.1.1.
 SHOW THE HOT WATER RECIRCULATION LINE WILL ALSO MAKE
 CONNECTION TO THE COLD WATER INLET PIPE OR THE HOT
 WATER RETURN CONNECTION OF THE THERMOSTATIC MIXING
 VALVE- SEC. 607.2.2 FBC P. PLEASE INCLUDE THE TMV IN
 THE EQUIPMENT SCHEDULE ON P001.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-03-09 Cont ID  
Sent By ccole Date 2023-03-09 Time 11:33 Rev Time 0.00
Received By ccole Date 2023-03-08 Time 17:22 Sent To  
Notes
2023-03-09 11:38:221ST REVIEW FBC-2020 PLUMBING
 PERMIT-23030381
 3/9/2023
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P100- IMPORTANT NOTE: SEPARATE PERMITS ARE
 REQUIRED FOR THE POTABLE WATER SERVICE BACKFLOW
 PREVENTER AND THE GREASE INTERCEPTOR, AND PERMIT
 APPLICATIONS FOR EACH SHALL BE SUBMITTED PRIOR TO
 APPROVAL OF THE MAIN PLUMBING PLANS FOR THE PROJECT.
 YOU CAN SUBMIT APPLICATIONS TBD (TO BE DETERMINED) IF
 YOU DO NOT HAVE CONTRACTORS SELECTED BY EMAILING
 COMPLETED PERMIT APPLICATIONS TO
 [email protected] . YOU WILL RECEIVE INSTRUCTIONS
 TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND
 PAY FEES AT A FUTURE DATE, BUT THE APPLICATIONS ARE
 REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES
 AND UPLOAD PLANS AT THE SAME TIME. AFTER YOU HAVE THE
 PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL AND I WILL
 CHANGE THE REVIEW STATUS TO PASS.
  
 2) P-100 & P-200: PROVIDE PLUMBING FIXTURE CALCULATIONS
 FOR THE NEW BUILDING IN ACCORDANCE WITH TABLE 403.1 FBC
 P. PROVIDE SCHEDULES THAT SHOW THE REQUIRED AND
 PROVIDED NUMBER OF FIXTURES FOR EACH SEPARATE OCCUPANCY
 OR TENANT SPACE. THE CALCULATIONS SHALL CLARIFY WHICH
 TENANT SPACES WILL ARE BEING SERVICED BY THE NEW GANG
 BATHROOMS, DRINKING FOUNTAINS AND JANITOR???S SINK.
  
 3) P-100: SANITARY AND GREASE WASTE STUB UPS ARE NOT
 SHOWN IN THE FUTURE TENANT 110 SPACE. IT WOULD APPEAR
 AT MINIMUM A SANITARY STUB-UP WOULD BE NECESSARY- SEC.
 107.2.1 WPB.
  
 4) P-100: NUMEROUS PLUMBING KEY NOTES REFERENCE THE
 CIVIL PLANS WHICH HAVE NOT BEEN UPLOADED FOR REVIEW-
 SEC. 107.2.1 WPB.
  
 5) P-100: THE FUTURE GREASE INTERCEPTOR PLAN REVIEW
 SUBMITTAL SHALL INCLUDE THE FOLLOWING ITEMS.
  
 A) GREASE WASTE PIPING ISOMETRIC AND A PIPING LAYOUT
 PLAN SHOWING PIPE RUNS FROM THE INDIVIDUAL FIXTURES TO
 THE MAIN WASTE LINE, WASTE LINE RUN TO THE INTERCEPTOR,
 AND OUTLET LINE TO POINT OF CONNECTION TO THE SANITARY
 SEWER- SEC. 107.2.1 WPB.
  
 B) EQUIPMENT SCHEDULE INDICATING THE MAKE, AND MODEL
 AND CAPACITY OF THE UNIT- SEC. 1003.3.5.
  
 C) SIZING CALCULATIONS IN ACCORDANCE WITH ASME
 A112.14.3, ASME A112.14.4, ASME A112.14.6, CSA B481.3,
 OR PDI G101 FOR HYDROMECHANICAL TYPES- SEC.1003.5.1.
  
 D) AN ENLARGED PIPING DIAGRAM OR ISOMETRIC SHOWING THE
 SIZES OF INLETS, OUTLETS, CLEANOUTS, AND VENTS- SEC.
 107.3.5.1.3 WPB. PLEASE INCLUDE A DETAIL FOR THE
 CLEANOUT WHICH WILL BE USED AS THE SAMPLING PORT BY THE
 WPB UTILITIES DEPT.
  
 6) P-700: THE SANITARY RISER APPEARS TO SHOW IMPROPER
 WET-VENTING FOR THE MEN???S AND WOMEN???S BATHROOM
 FIXTURES PER ITEMS A-D BELOW.
  
 A) URINALS ARE NOT INCLUDED IN THE DEFINITION OF A
 BATHROOM GROUP SO THEIR FIXTURE DRAINS SHALL NOT
 CONNECT TO THE WET VENT, AND THEIR DRY VENTS SHALL NOT
 BE THE DRY VENT FOR THE SYSTEM- SECS. 202 & 912.1 FBC
 P. IN ORDER TO FIX THE BRANCH, THE URINAL DRAINS SHALL
 CONNECT DOWNSTREAM OF THE L2/WC-1 WET VENT, AND A
 COMMON VENT OR INDIVIDUAL VENTS FOR THE URINALS SHALL
 BE PROVIDED- SECS. 910.1 & 911.1.
  
 B) THE TWO WET VENT BRANCHES SHOWING 3- WATER CLOSETS
 (WC-1) AND 3- LAVATORIES (L-1) ARE NOT IN COMPLIANCE
 WITH 912.1 BECAUSE NOT MORE THAN TWO OF ANY FIXTURE
 TYPE CAN CONNECT TO A WET-VENT SYSTEM. TO FIX THE
 BRANCHES, INDIVIDUAL OR COMMON WC-1 & L-1 VENTS SHALL
 BE PROVIDED- SECS. 910.1 & 911. THE L-1 BRANCH CAN ALSO
 BE CIRCUIT VENTED IF DESIGNED IN ACCORDANCE WITH SEC.
 914.1- 914.3.
  
 C) THE BRANCH SHOWING THE 3- LAVATORIES AND THE
 JANITOR'S SINK WITH INDIVIDUAL VENT CAN BE FIXED BY
 PROVIDING EITHER INDIVIDUAL VENTS OR COMMON VENTS FOR
 THE LAVS, OR A CIRCUIT VENT FOR THE WHOLE BRANCH CAN BE
 DESIGNED IN ACCORDANCE WITH SECS. 914.1- 914.3 FBC P.
  
 D) PROVIDE VENTING FOR THE HD AND FD-1- SEC. 901.2.1
 FBC P. PLEASE NOTE THAT BASED ON P-100 THERE APPEARS TO
 BE ONE FD-1 MISSING FROM THE ISOMETRIC DRAWING.
  
 7) P-700: SHOW TRAP SEAL PROTECTION FOR THE FD-1 AND
 HD-1: SEC. 1002.4.1 FBC P.
  
 8) P-700 WATER RISER: SHOW THE SIZES OF THE SUPPLY
 PIPES TO UR-1 AND WC-1- TABLE 604.5 FBC P.
  
 9) P-700: TEMPERED WATER SHALL BE DELIVERED FROM THE
 LAVATORIES THROUGH A WATER TEMPERATURE LIMITING DEVICE
 THAT CONFORMS TO ASSE 1070- SECS. 419.5 & 607.1.2 FBC
 P.
  
 10) P-700: THE 3/4 -INCH HOT WATER FIXTURE SUPPLY PIPES
 TO THE LAVATORIES ARE EXCEEDING THEIR MAXIMUM ALLOWABLE
 LENGTHS OF 0.5 FT. FROM THE HOT WATER SOURCE TO THE
 PIPE TERMINATION. THE NEAREST SOURCE IN THIS CASE IS
 THE RECIRCULATION LINE- TABLE C404.5.1 FBC ENERGY.
  
 11) P-500: PLEASE PROVIDE A WATER HEATER DETAIL THAT
 SHOW THE PIPING CONNECTIONS TO THE RECIRCULATION PUMP,
 REQUIRED EXPANSION TANK AND THE REQUIRED MASTER
 THERMOSTATIC MIXING VALVE- SECS. 607.2.2 & 607.3 FBC P.
 PLEASE NOTE THE MASTER MIXING VALVE IS REQUIRED BECAUSE
 THE THERMOSTAT ON THE WATER HEATER CANNOT BE THE
 TEMPERATURE LIMITING MEANS FOR THE HOT WATER SYSTEM-
 SEC. 607.1.1.
  
 12) P-700: PLEASE SHOW THE DRAINAGE GPM'S AT THE ROOF
 DRAINS AND THE ACCUMULATIVE GPM FLOW THROUGH THE
 VERTICAL LEADERS AND HORIZONAL STORM PIPES TO THE
 DISPOSAL LOCATIONS- TABLES 1106.2 & 1106.3 FBC P.
  
 13) A104 & A104A: PLEASE PROVIDE THE FOLLOWING FBC ACC
 COMPLIANCE DETAILS FOR THE ACCESSIBLE BATHROOM FIXTURES
 AND DRINKING FOUNTAINS. PLEASE NOTE KEYNOTES 1-4 NOT
 SHOWN ON THE DRAWINGS.
 A) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE
 WATER CLOSETS- SEC. 604.3.
 B) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE
 LAVATORIES- SEC. 606.2.
 C) TURNING SPACE DIAMETERS- SEC. 304.3.
 D) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE WALLS
 AND PARTITIONS- SEC. 604.2.
 E) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED
 FLOORS- SEC. 604.4.
 F) HEIGHTS OF THE ACCESSIBLE COMPARTMENT LAVATORY SINK
 RIMS FROM THE FINISHED FLOORS- SEC. 606.3.
 G) HEIGHTS OF THE ACCESSIBLE COMPARTMENT MIRRORS FROM
 THE FINISHED FLOORS TO THE REFLECTIVE SURFACES- SECTION
 603.3
 H) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB
 BARS FOR THE WATER CLOSETS- SECS. 604.5 & 609.4,
 FIGURES 604.5.1 604.5.2.
 I) CENTERLINES OF THE TOILET PAPER DISPENSERS MEASURED
 FROM THE FRONTS OF THE WATER CLOSETS- SEC. AND FIGURE
 604.7.
 J) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SEC.
 606.2.
 K) REFER TO SECTIONS 306, 307, AND 602 FBC ACC AND
 PROVIDE DRINKING FOUNTAIN INSTALLATION DETAILS AND
 ELEVATION VIEWS SHOWING KNEE AND TOE CLEARANCES, SPOUT
 HEIGHTS, AND SPOUT LOCATIONS. SHOW THE REQUIRED 30 X 48
 IN. CLEAR FLOOR SPACE FOR A FORWARD WHEELCHAIR APPROACH
 TO THE FOUNTAIN- SEC. 602.2 FBC ACC, AND SHOW HOW THE
 LOCATIONS OF THE FOUNTAINS WILL BE IN COMPLIANCE WITH
 SEC. 307.2 PROTRUSION LIMITS. IT APPEARS ONE SIDE OF
 THE FOUNTAIN IS BEYOND THE 4-INCH MAXIMUM PROTRUSION
 LIMITATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2023-03-23 Cont ID  
Sent By rmcphers Date 2023-03-23 Time 14:49 Rev Time 0.00
Received By rmcphers Date 2023-03-23 Time 14:49 Sent To  
Notes
2023-03-23 14:49:31ROOFING SYSTEM TO BE DEFERRED

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-07-07 Cont ID  
Sent By rmcphers Date 2023-07-07 Time 13:17 Rev Time 0.00
Received By rmcphers Date 2023-07-07 Time 13:17 Sent To  
Notes
2023-07-07 10:17:02PLUMBING SIGNATURES PASSED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-05-15 Cont ID  
Sent By rmcphers Date 2023-05-15 Time 13:44 Rev Time 0.00
Received By rmcphers Date 2023-05-15 Time 13:44 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-04-06 Cont ID  
Sent By lbond Date 2023-03-20 Time 11:56 Rev Time 0.00
Received By lbond Date 2023-03-20 Time 11:56 Sent To  
Notes
2023-03-20 11:57:27ARCHITECT SIGNATURE AND SEAL DIGITALLY - PASSED
2023-03-16 18:29:20ELECTRICAL PLANS PASS JLEAHY
2023-03-10 06:16:59MECHANICAL DIGITAL SIGNATURES APPROVED ME
2023-03-09 12:35:04PLUMBING (P) PLANS PASSED

Review Stop Z ZONING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2023-05-30 Cont ID  
Sent By ckimmerl Date 2023-05-30 Time 10:24 Rev Time 0.00
Received By ckimmerl Date 2023-05-30 Time 10:23 Sent To  
Notes
2023-05-30 10:24:08PROPOSAL FOR 818 N RAILROAD AVENUE HAS BEEN SUBMITTED
 FOR FORMAL SITE PLAN APPROVAL AND HAS NOT RECEIVED SAID
 APPROVAL.
 ZONING STAFF CANNOT REVIEW OR APPROVE OF THE BUILDING
 PERMIT WITHOUT FIRST RESUBMITTING AND OBTAINING THE
 SITE PLAN APPROVAL FOR FSPR 22-16 (Z22070023).
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2023-03-21 Cont ID  
Sent By CKimmerl Date 2023-03-21 Time 11:05 Rev Time 0.00
Received By ckimmerl Date 2023-03-21 Time 11:04 Sent To  
Notes
2023-03-21 11:05:471. PROPOSAL FOR 818 N RAILROAD AVENUE HAS BEEN
 SUBMITTED FOR FORMAL SITE PLAN APPROVAL AND HAS NOT
 RECEIVED SAID APPROVAL.
 ZONING STAFF CANNOT REVIEW OR APPROVE OF THE BUILDING
 PERMIT WITHOUT FIRST RESUBMITTING AND OBTAINING THE
 SITE PLAN APPROVAL FOR FSPR 22-16 (Z22070023).
  
 2. PLEASE PROVIDE SITE SURVEY.
  
 CHRIS KIMMERLY, AICP
 URBAN DESIGN PLANNER
 [email protected] 822-1426
  