| Plan Review Stops For Permit 23030379 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2023-06-22 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2023-06-22 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-04-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-04-10 |
Time |
09:13 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-04-10 |
Time |
09:13 |
Sent To |
|
|
| Notes |
| 2023-04-10 09:23:17 | LIGHT POLES | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) AS NOTED ON DRAWING E101 - NEED A SIGNED AND SEALED | | | DRAWING THAT INCLUDES THE ENTIRE ASSEMBLY (POLE AND | | | FIXTURE) - PLEASE PROVIDE SIGNED AND SEALED LIGHT POLE | | | DRAWINGS SHOWING THE WIND DESIGN PARAMETERS FROM A | | | DESIGN PROFESSIONAL AS NOTED ON THE PROVIDED DRAWINGS. | | | FBC 1609 | | | | | | 2) POLE DRAWING FROM "VALMONT" DOES NOT INCLUDE THE | | | LIGHT FIXTURE. POLE LENGTH AND EMBEDMENT DEPTH DOES NOT | | | MATCH DRAWING E101 AND IT IS NOT SIGNED AND SEALED BY | | | THE DESIGNER. FBC WPB 107.1 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-24 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-24 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2023-03-24 15:12:12 | LIGHT POLES | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) PLEASE PROVIDE SIGNED AND SEALED LIGHT POLE DRAWINGS | | | SHOWING THE WIND DESIGN PARAMETERS FROM A DESIGN | | | PROFESSIONAL AS NOTED ON THE PROVIDED DRAWINGS. FBC | | | 1609 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-04-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-04-13 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-04-13 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-03-09 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-03-09 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-03-09 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2023-03-09 13:54:42 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | | | | NOTE #2 CALLS FOR CCTV SYSTEM INSIDE OR OUTSIDE OF | | | POLE? SEE BELOW. EXPLAIN HOW WIRING IS TO BE DONE. | | | | | | CABLES AND CONDUCTORS OF CLASS 2 AND CLASS 3 CIRCUITS | | | SHALL NOT BE PLACED IN ANY CABLE, CABLE TRAY, | | | COMPARTMENT, ENCLOSURE, MANHOLE, OUTLET BOX, DEVICE | | | BOX, RACEWAY, OR SIMILAR FITTING WITH CONDUCTORS OF | | | ELECTRIC LIGHT, POWER, CLASS 1, NON???POWER-LIMITED | | | FIRE ALARM CIRCUITS, AND MEDIUM-POWER NETWORK-POWERED | | | BROADBAND COMMUNICATIONS CIRCUITS UNLESS PERMITTED BY | | | 725.136(B) THROUGH (I). |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-04-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-04-13 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-04-07 |
Time |
16:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-24 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-03-24 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-03-07 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-06-22 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2023-06-22 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2023-06-22 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2023-04-10 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-04-10 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-04-10 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2023-04-10 09:27:28 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE POLE DRAWING FROM VALMONT DOES NOT SHOW AS | | | DIGITALLY SIGNED IN ADOBE READER - | | | | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-04-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-03-09 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-03-09 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2023-03-09 13:55:29 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | NOT ABLE TO VERIFY SIGNATURES. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
2023-03-14 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
2023-03-14 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2023-03-14 12:11:25 | 3/14/23 ??? PASSED | | | | | | | | | KEVIE DEFRANC | | | SENIOR PLANNER - PLANNING DIVISION | | | [email protected] | | | 561-822-1449 | | | |
|
|