| Plan Review Stops For Permit 23030377 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-06-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-06-06 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-06-06 |
Time |
16:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-04-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-04-04 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-04-04 |
Time |
14:09 |
Sent To |
|
|
| Notes |
| 2023-04-04 14:09:14 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT THE MANUFACTURER'S SPECIFICATIONS FOR THE | | | PROPOSED GENERATOR. FBC AMENDMENTS 107.2.1 | | | | | | 2) SUBMIT SIGNED AND SEALED GENERATOR PAD DRAWINGS WITH | | | GENERATOR TO PAD ANCHORING DETAILS FOR WIND LOADS. FBC | | | 1601 | | | | | | 3) PROVIDE A SITE PLAN THAT SPECIFIES THE LOCATION OF | | | THE PROPOSED GENERATOR. FBC 107.2.1 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-06-05 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-06-05 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-06-05 |
Time |
12:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-03-21 |
|
|
Cont ID |
|
| Sent By |
rperdomo |
Date |
2023-03-21 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
rperdomo |
Date |
2023-03-21 |
Time |
12:34 |
Sent To |
|
|
| Notes |
| 2023-03-21 12:53:56 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW | | | | | | 1. PROVIDE GENERATOR AND ATS SPECS. FBC 107.3.5 | | | | | | END OF COMMENTS | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | RUBEN PEREZ PERDOMO, P.E. | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6738 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2023-05-26 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-05-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-05-26 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2023-03-09 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2023-03-09 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
2023-03-09 |
Time |
|
Sent To |
|
|
| Notes |
| 2023-03-09 10:59:50 | FIRE REVIEW COMMENTS: | | | | | | THIS SUBMITTAL WAS REVIEWED AND FAILED DUE TO A LACK OF | | | SUFFICIENT INFORMATION FOR A PROPER CODE REVIEW. | | | PROVIDE DOCUMENTATION ON THE TYPE AND SIZE OF GENERATOR | | | TO BE INSTALLED, AUTOMATIC TRANSFER, TYPE OF FUEL, | | | DISTANCE TO BUILDINGS OR BUILDING OPENINGS, AND ANY | | | OTHER ITEM THAT WILL INDICATE THE INSTALLATION COMPLIES | | | WITH NFPA 110, NFPA 37, NFPA 70 AND ANY OTHER | | | APPLICABLE CODE. NFPA 1, 11.7 | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-06-07 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2023-06-07 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2023-05-25 |
Time |
08:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-04-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-04-04 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-03-08 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2023-06-07 |
|
|
Cont ID |
|
| Sent By |
dbattles |
Date |
2023-06-07 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
dbattles |
Date |
2023-06-07 |
Time |
15:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-13 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-13 |
Time |
15:14 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-13 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2023-03-13 15:15:10 | NO MECHANICAL WORK SHOWN FOR THIS PROJECT. PROVIDE THE | | | GENERATOR SPECS AND LOCATION. FBC 107.3.5 |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-06-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-06-06 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-06-06 |
Time |
16:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-04-04 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-04-04 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-04-04 |
Time |
14:14 |
Sent To |
|
|
| Notes |
| 2023-04-04 14:14:35 | THE CIVIL PLANS HAVE NOT BEEN DIGITALLY SIGNED BY THE | | | ENGINEER LISTED IN THE TITLE BLOCKS OF THE DRAWINGS. | | | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | | THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE ON THEM. | | | FS 481 & FAC 61G1 OR FS 471 & FAC 61G15 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-04-17 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
2023-04-17 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
2023-04-17 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2023-04-17 13:40:17 | 4/17/23 ??? PASSED | | | | | | REVIEW COMMENT TO BE ADDRESSED: | | | 1. PLEASE PROVIDE THE APPROVED SITE PLAN (SHEET NUMBER | | | SP101 ASSOCIATED WITH THE MASTER PERMIT # 21090266) AND | | | IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION OF THE | | | PROPOSED BACK UP GENERATOR. [SATISFIED] | | | | | | | | | KEVIE DEFRANC | | | SENIOR PLANNER - PLANNING DIVISION | | | [email protected] | | | 561-822-1449 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
kdefranc |
Date |
2023-03-14 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
kdefranc |
Date |
2023-03-14 |
Time |
12:56 |
Sent To |
|
|
| Notes |
| 2023-03-14 12:56:48 | 3/14/23 ??? FAILED | | | | | | REVIEW COMMENT TO BE ADDRESSED: | | | 1. PLEASE PROVIDE THE APPROVED SITE PLAN (SHEET NUMBER | | | SP101 ASSOCIATED WITH THE MASTER PERMIT # 21090266) AND | | | IDENTIFY/INDICATE/DEMONSTRATE THE LOCATION OF THE | | | PROPOSED BACK UP GENERATOR. | | | | | | | | | KEVIE DEFRANC | | | SENIOR PLANNER - PLANNING DIVISION | | | [email protected] | | | 561-822-1449 | | | |
|
|