Plan Review Details - Permit 23021503
Plan Review Stops For Permit 23021503
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2023-06-01 Cont ID  
Sent By cpuell Date 2023-06-01 Time 09:20 Rev Time 0.00
Received By cpuell Date 2023-06-01 Time 09:20 Sent To  
Notes
2023-06-01 09:21:30THE ADDRESS OF 3406 WASHINGTON RD HAS BEEN ASSIGNED TO
 THE SECOND UNIT.

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2023-05-27 Cont ID  
Sent By cpuell Date 2023-05-27 Time 08:20 Rev Time 0.00
Received By cpuell Date 2023-05-27 Time 08:20 Sent To  
Notes
2023-05-27 08:22:16ZONING HAS APPROVED A SECONDARY UNIT, AN ADDRESS WILL
 NEED TO BE ASSIGNED TO THE SECOND UNIT, PLEASE HAVE THE
 OWNERS REACH OUT TO [email protected] OR CALL
 561-805-6659

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2023-04-05 Cont ID  
Sent By cpuell Date 2023-04-05 Time 07:43 Rev Time 0.00
Received By cpuell Date 2023-04-05 Time 07:43 Sent To  
Notes
2023-04-05 07:44:40A SECONDARY ADDRESS MAY NEED TO BE ASSIGNED IF ZONING
 APPROVES A SECONDARY UNIT. PLEASE CONTACT
 [email protected] OR CALL 561-805-6659 ONCE ZONING
 APPROVES THEIR REVIEW.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-07-05 Cont ID  
Sent By jgomez Date 2023-07-05 Time 18:25 Rev Time 0.00
Received By jgomez Date 2023-06-30 Time 17:42 Sent To  
Notes
2023-07-06 09:37:24SINGLE FAMILY RESIDENCE (R3)SECOND BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23021503
 3408 WASHINGTON RD
  
 ORIGINAL COMMENT:
 1- THIS BUILDING IS GOING TO BE BUILT IN A AE FLOOD
 ZONE WITH THE BASE FLOOD BFE: 6 FEET BASED ON NAVD
 1988.
 CITY OF WEST PALM BEACH ORDINANCE REQUIRES A TWO (2)
 FOOT FREE BOARD ABOVE THE BASE FLOOD ELEVATION (SEC.
 18-284 CITY ORDINANCE NO. 4729-17).
 DESIGNER OF RECORD NEEDS TO SPECIFY THE PROPOSED FINISH
 ELEVATIONS, INCLUDING ALL EQUIPMENT SERVING THE TWO
 BUILDINGS.
 DURING THE PERMITTING/CONSTRUCTION OF THIS STRUCTURE
 THREE DIFFERENT FLOOD ELEVATION CERTIFICATES WILL BE
 REQUIRED (SEC. 107.3.5.1.1 CITY AMENDMENTS):
 A) CONSTRUCTION DRAWINGS. B) BUILDING UNDER
 CONSTRUCTION. C) FINISHED CONSTRUCTION.
 NOTE:
 NEED TO PROVIDE THE CONSTRUCTION DRAWINGS ELEVATION
 CERTIFICATE NOW FOR REVIEW.
 ALSO, NEED TO PROVIDE SURVEY TO VERIFY ELEVATIONS
 SPECIFIED ON ELEVATION CERTIFICATE.
  
 RESPONSE:
 (1)CONSTRUCTION DRAWINGS ELEVATION CERTIFICATE WAS NOT
 PROVIDED.
 (2)PROPOSED 3408 WASHINGTON RD SURVEY DOESN'T SHOW THE
 PROPOSED FINISH FLOOR ELEVATIONS AND DOESN'T SHOW THE
 PROPOSED GRADE ELEVATIONS ADJACENT TO THE BUILDING IN
 ORDER TO VERIFY INFORMATION ON ELEVATION CERTIFICATE.
 (3)DRAWING LABELED "70400 PLOT PLN 11X17 LANDSCAPE
 05-25-2023 SIGNED" IS A SURVEY SHOWING THE PROPOSED
 FINISH FLOOR ELEVATIONS OF THE MAIN HOUSE AND THE
 GARAGE. THE MAIN HOUSE FINISH FLOOR DOESN'T MATCH PLANS
 AND IS MISSING THE PROPOSED GRADE ELEVATIONS ADJACENT
 TO THE BUILDINGS ALSO. THIS DRAWING WAS BLOCKED BECAUSE
 IT WAS MISLABELED AS LANDSCAPE INSTEAD OF PROPOSED
 SURVEY. LANDSCAPE PLANS ARE SUBMITTED UNDER A SEPARATE
 PERMIT. PLEASE PROVIDE ONLY ONE PROPOSED SURVEY WITHE
 THE REQUIRED ELEVATIONS TO AVOID CONFLICTS/DELAYS.
  
 3-FUTURE ELEVATOR:
 ORIGINAL COMMENT:
 A) FUTURE ELEVATOR LOCATION IS NOT CLEAR. INFORMATION
 ON GROUND FLOOR FRAMING PLAN AND SECOND FLOOR FRAMING
 PLAN INFORMATION DOESN'T MATCH INFORMATION ON PROPOSED
 FIRST AND SECOND FLOOR PLANS. REVISE AS REQUIRED TO
 MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 RESPONSE:
 REVISED STRUCTURAL PLANS AS SPECIFIED ON ARCHITECT'S
 RESPONSE LETTER WERE NOT SUBMITTED.
  
 ORIGINAL COMMENT:
 B) PROVIDE COMPLETE FRAMING DETAIL/SPECIFICATIONS FOR
 FUTURE ELEVATOR CHASE. SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 REVISED STRUCTURAL PLANS AS SPECIFIED ON ARCHITECT'S
 RESPONSE LETTER WERE NOT SUBMITTED.
  
 ORIGINAL COMMENT:
 C)BASED ON BUILDING SECTION 1 ON SHEET A-7.1 THE
 ELEVATOR EQUIPMENT WILL BE BELOW THE REQUIRED 2 FEET
 FREEBOARD. COORDINATE WITH SEC. R322 FBC-RESIDENTIAL
 FOR EQUIPMENT PROTECTION AND ENCLOSURE CONSTRUCTION.
  
 RESPONSE:
 ELEVATOR INSTALLATION. PROVIDE COMPLETE ELEVATOR
 INFORMATION UNDER A SEPARATE PERMIT WHEN READY TO
 INSTALL THE ELEVATOR.
  
 ORIGINAL COMMENT:
 10- EGRESS WINDOWS NOTE ON SHEET A-4.1 IS INCORRECT.
 SEE SEC. R310.2.1 FBC-RESIDENTIAL AND REVISE AS
 REQUIRED.
  
 RESPONSE:
 REPEAT COMMENT. NOTE WAS NOT REVISED. NEED TO REVISE
 THIS NOTE. IT IS INCORRECT AND IS MISLEADING. SEE SEC.
 R310.2.1 FBC-RESIDENTIAL AND REVISE AS REQUIRED.
  
 ORIGINAL COMMENT:
 11- DOOR & WINDOW WIND PRESSURES TABLE ON SHEET S-5
 SPECIFY EXPOSURE C-180MPH WIND SPEED. ACCORDING TO SEC.
 R301.2.1.4.3 FBC-RESIDENTIAL THIS BUILDING IS LOCATED
 IN EXPOSURE "D" NOT "C". REVISE ALL WIND DESIGN
 PRESSURES AS REQUIRED.
  
 RESPONSE:
 REVISED STRUCTURAL PLANS AS SPECIFIED ON ARCHITECT'S
 RESPONSE LETTER WERE NOT SUBMITTED.
  
 ORIGINAL COMMENT:
 12-PLYWOOD SHEATHING NAILING SCHEDULE ON SHEET S-5 :
 REVISE ROOF SHEATHING NAILING SPECIFICATIONS TO COMPLY
 WITH NEW 2020 FBC-RESIDENTIAL SPECIFICATIONS. REVISE
 TYPE, SIZE AND SPACING. NOTE: NEED TO USE RING SHANK
 NAILS. ROOF SHEATHING NEEDS TO BE NAILED AT 4 INCHES
 O.C. IN THE FIELD AND EDGES AS REQUIRED BY SEC.
 R803.2.3.1 AND TABLE R803.2.3.1 FBC-RESIDENTIAL.
 NOTE: REVISE SPECIFICATIONS OR PROVIDE CALCULATIONS
 SHOWING THAT SPECIFIED NAIL TYPE AND SPACING MATCHES OR
 EXCEEDS TABLE R803.2.3.1 FBC-RESIDENTIAL MINIMUM
 REQUIREMENTS.
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 RESPONSE:
 REVISED STRUCTURAL PLANS AS SPECIFIED ON ARCHITECT'S
 RESPONSE LETTER WERE NOT SUBMITTED.
  
 13- ENERGY CALCULATIONS (MAIN HOUSE):
 ORIGINAL COMMENT:
 A)THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY AT THE OWNER/AGENT LINE AT THE BOTTOM OF FORM
 THAT THE BUILDING IS IN COMPLIANCE WITH THE CODE, AS
 PER SECTION 553.907, FLORIDA STATUTES, PRIOR TO
 RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION AS REQUIRED BY SECTION R103.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER'S NAME, BUILDER'S NAME. SEC.
 R101.5.1.1.2 FBC- ENERGY CONSERVATION.
  
 RESPONSE:
 OWNER'S NAME IS INCORRECT. PROVIDE CORRECT NAME.
  
 ORIGINAL COMMENT:
 D)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC-ENERGY
 CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 14- ENERGY CALCULATIONS (GUEST HOUSE):
 ORIGINAL COMMENT:
 A)THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY AT THE OWNER/AGENT LINE AT THE BOTTOM OF FORM
 THAT THE BUILDING IS IN COMPLIANCE WITH THE CODE, AS
 PER SECTION 553.907, FLORIDA STATUTES, PRIOR TO
 RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION AS REQUIRED BY SECTION R103.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 C)ENERGY CALCULATIONS ARE TAKEN THE CEILING FAN CREDIT.
 PLANS DON'T SHOW CEILING FANS FOR ALL REQUIRED ROOMS.
 REVISE AS REQUIRED TO MATCH PLANS. IF TAKING THE
 CEILING FAN CREDIT, THEN PLANS NEED TO SHOW CEILING FAN
 AND SIZE IN ALL THE ROOMS AS REQUIRED BY TABLE R405.7.6
 FBC-ENERGY CONSERVATION
 NOTE: SEE SIZE AND NUMBER OF FANS REQUIRED BASED ON
 ROOM SIZE.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 D)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC-ENERGY
 CONSERVATION.
  
 RESPONSE:
 REPEAT COMMENT. NOT ADDRESSED.
  
 15- PRODUCT APPROVALS DEFERRED SUBMITTAL: AS REQUESTED
 BY THE ARCHITECT AND OWNER THE PRODUCT APPROVALS WILL
 BE SUBMITTED LATER.
 NOTE: SUBMIT FOR REVIEW AFTER THE PERMIT IS ISSUED BUT
 BEFORE INSPECTIONS TO AVOID CONFLICTS/DELAYS.
 A)EXTERIOR DOORS AS SHOWN ON PLANS. (NOTE: PLEASE
 IDENTIFY EACH PRODUCT APPROVAL. FOR EXAMPLE ENTRY DOOR,
 GARAGE SWING DOOR, ETC.)
 B)WINDOWS AS SHOWN ON PLANS.
 C)WINDOWS AND DOORS MULLIONS (NOTE: NEED TO SPECIFY
 MULLION SIZE TO VERIFY PRESSURES. SEC. R301.2.1
 FBC-RESIDENTIAL).
 D)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE CITY SAMPLE.
 E)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE
 USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC
 R301.2.1 FBC-RESIDENTIAL.
 F)ROOFING UNDERLAYMENT SPECIFIED ON PLANS.
 G)ROOF TILE ADHESIVE ( IF USED) LISTED IN ROOF TILE
 PRODUCT APPROVAL.
 H)HIP & RIDGE METAL SUPPORT TO BE USED.
 L)BALCONY UNDERLAYMENT SPECIFIED ON PLANS TO RECEIVE
 TILE.
 M)FLOOD VENTS SPECIFIED BY THE DESIGNER OF RECORD.
 N)OVERHEAD GARAGE DOORS.
  
 ORIGINAL COMMENT:
 17- HOUSE IS DESIGNED WITH UNVENTED ATTIC. ARCHITECT IS
 SPECIFYING R-30 ICYNENE SPRAY INSULATION. PROVIDE ICC
 EVALUATION REPORT FOR THE ICYNENE R-30 INSULATION TO
 VERIFY COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL.
 NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN
 WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
 NOTE: THIS COULD BE A DEFERRED SUBMITAL ALSO.
  
 RESPONSE:
 ICC EVALUATION REPORT ESR-1826 SUBMITTED IS EXPIRED. IT
 WAS SUBJECT TO RENEWAL ON FEBRUARY 2022. SEE TOP RIGHT
 CORNER OF REPORT. PROVIDE CURRENT REPORT.
  
 ORIGINAL COMMENT:
 20- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR
 PERGOLAS OR TRELLIS SHOWN ON THE MAIN HOUSE AND
 SEPARATE GUEST HOUSE. SPECIFY ALL FRAMING MEMBERS AND
 CONNECTORS. SEC. R301.1 FBC-RESIDENTIAL.
  
 RESPONSE:
 REVISED STRUCTURAL PLANS AS SPECIFIED ON ARCHITECT'S
 RESPONSE LETTER WERE NOT SUBMITTED.
  
 ORIGINAL COMMENT:
 23- SHEET C-1: ENGINEER DIGITAL SIGNATURE DOESN'T SEEM
 TO COMPLY WITH THE REQUIREMENTS OF SEC. 61G15-23.004.
 IT DOESN'T HAVE A TITLE BLOCK, THE REQUIRED TEXT BOX
 LANGUAGE. IT ONLY SHOWS DIGITALLY SIGNED BY RICHARD V
 REIKENIS AND THE DATE. IT DOESN'T IDENTIFY THE
 ENGINEER'S LICENSE NUMBER.
 SEE SEC. 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING
 AND SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS AND RESUBMIT
 DRAWING WITH VERIFIABLE DIGITAL SIGNATURE.
  
 RESPONSE:
 ENGINEER'S DIGITAL SIGNATURE DOESN'T COMPLY WITH THE
 REQUIREMENTS OF FBPE. NEED A SEPARATE TEXT BOX WITH THE
 TEXT BOX LANGUAGE IDENTICAL TO THE SAMPLES SHOWN BY
 FBPE.
 SEE FBPE.ORG/LEGAL/SIGNING-AND-SEALING-ENGINEERING-DOCU
 MENTS/ AND REVISE DIGITAL SIGNATURE AS REQUIRED.
 NOTE: THIS WAS CONFIRMED WITH THE FBPE INVESTIGATOR.
  
 SEC. 61G15-23.004 F.A.C. PROCEDURES FOR DIGITALLY
 SIGNING AND SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 NEW COMMENT BASED ON COMMENTS FROM ADDRESSING REVIEW
 REGARDING THE APPROVAL OF THE GARAGE/APARTMENT BY
 ZONING.
 24- A SEPARATE PERMIT APPLICATION (INCLUDING ALL
 SUB-PERMITS) IS REQUIRED SINCE THE GARAGE/APARTMENT WAS
 ASSIGNED A DIFFERENT ADDRESS (3406 WASHINGTON RD).
 THIS NEW BUILDING WILL REQUIRE A CERTIFICATE OF
 OCCUPANCY. SEPARATE PERMIT APPLICATION WILL FACILITATE
 RECORDS MANAGEMENT. SEC. 105.1 CITY AMENDMENTS. SEC.
 107.2.1.3 CITY AMENDMENTS.
 NOTE: SAME SET OF PLANS CAN BE USED.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-04-18 Cont ID  
Sent By jgomez Date 2023-04-18 Time 17:01 Rev Time 0.00
Received By jgomez Date 2023-04-18 Time 16:53 Sent To  
Notes
2023-04-18 17:01:21SINGLE FAMILY RESIDENCE (R3)BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23021503
 3408 WASHINGTON RD
  
 1- THIS BUILDING IS GOING TO BE BUILT IN A AE FLOOD
 ZONE WITH THE BASE FLOOD BFE: 6 FEET BASED ON NAVD
 1988.
 CITY OF WEST PALM BEACH ORDINANCE REQUIRES A TWO (2)
 FOOT FREE BOARD ABOVE THE BASE FLOOD ELEVATION (SEC.
 18-284 CITY ORDINANCE NO. 4729-17).
 DESIGNER OF RECORD NEEDS TO SPECIFY THE PROPOSED FINISH
 ELEVATIONS, INCLUDING ALL EQUIPMENT SERVING THE TWO
 BUILDINGS.
 NOTE: MISSING INFORMATION FOR CONDENSING UNIT #3 AND
 GUEST HOUSE EQUIPMENT.
  
 DURING THE PERMITTING/CONSTRUCTION OF THIS STRUCTURE
 THREE DIFFERENT FLOOD ELEVATION CERTIFICATES WILL BE
 REQUIRED (SEC. 107.3.5.1.1 CITY AMENDMENTS):
 A) CONSTRUCTION DRAWINGS.
 B) BUILDING UNDER CONSTRUCTION.
 C) FINISHED CONSTRUCTION.
  
 NOTE:
 NEED TO PROVIDE THE CONSTRUCTION DRAWINGS ELEVATION
 CERTIFICATE NOW FOR REVIEW.
 ALSO, NEED TO PROVIDE SURVEY AND FLOOD VENTS PRODUCT
 APPROVAL SPECIFIED BY THE ARCHITECT TO VERIFY
 ELEVATIONS AND NET FLOOD VENT NET AREA SPECIFIED ON
 ELEVATION CERTIFICATE.
  
 2-DESIGNER OF RECORD TO SPECIFY SIZE OF FLOOD VENTS.
 SEC. R322.2.2 FBC-RESIDENTIAL.
  
 3-FUTURE ELEVATOR:
 A) FUTURE ELEVATOR LOCATION IS NOT CLEAR. INFORMATION
 ON GROUND FLOOR FRAMING PLAN AND SECOND FLOOR FRAMING
 PLAN INFORMATION DOESN'T MATCH INFORMATION ON PROPOSED
 FIRST AND SECOND FLOOR PLANS. REVISE AS REQUIRED TO
 MATCH. SEC. 107.2.1 CITY AMENDMENTS.
  
 B) PROVIDE COMPLETE FRAMING DETAIL/SPECIFICATIONS FOR
 FUTURE ELEVATOR CHASE. SEC. R301.1 FBC-RESIDENTIAL.
  
 C)BASED ON BUILDING SECTION 1 ON SHEET A-7.1 THE
 ELEVATOR EQUIPMENT WILL BE BELOW THE REQUIRED 2 FEET
 FREEBOARD. COORDINATE WITH SEC. R322 FBC-RESIDENTIAL
 FOR EQUIPMENT PROTECTION AND ENCLOSURE CONSTRUCTION.
  
 4- SEPARATE PERMIT REQUIRED FOR THE EXISTING HOUSE
 DEMOLITION. SEC. 1075.1 CITY AMENDMENTS.
  
 5- SEPARATE PERMIT REQUIRED FOR THE RETAINING WALLS
 SHOWN ON THE SITE PLAN.
 1075.1 CITY AMENDMENTS.
  
 6- NEED BATHROOM #1 WITH A DOOR THAT PROVIDES 29" MIN.
 CLEAR OPENING AS REQUIRED BY SEC. R320.1.1
 FBC-RESIDENTIAL.
  
 7- SPECIFY ATTIC ACCESS SIZE AND LOCATION. SEC. R807
 FBC-RESIDENTIAL.
 NOTE: THIS APPLIES TO BOTH BUILDINGS.
  
 8- GUEST HOUSE ENTRY DOOR DOESN'T COMPLY WITH THE MIN.
 CLEAR WIDTH OF 32" AS REQUIRED BY SEC. R311.2
 FBC-RESIDENTIAL. REVISE AS REQUIRED.
  
 9-DRAFSTOPPPING DETAIL 1 ON SHEET A-2.1. CLARIFY HOW
 PROVIDING 24X36 ACCESS PANELS ON THE FLOOR/CEILING
 ASSEMBLY. SEE SIZE OF FLOOR TRUSSES SPECIFIED ON FLOOR
 FRAMING PLAN. PROVIDE COMPLETE DETAILS AND
 SPECIFICATIONS FOR SELF-CLOSING PANEL ACCESS.
 SEC. R302.12 FBC-RESIDENTIAL. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 10- EGRESS WINDOWS NOTE ON SHEET A-4.1 IS INCORRECT.
 SEE SEC. R310.2.1 FBC-RESIDENTIAL AND REVISE AS
 REQUIRED.
  
 11- DOOR & WINDOW WIND PRESSURES TABLE ON SHEET S-5
 SPECIFY EXPOSURE C-180MPH WIND SPEED. ACCORDING TO SEC.
 R301.2.1.4.3 FBC-RESIDENTIAL THIS BUILDING IS LOCATED
 IN EXPOSURE "D" NOT "C". REVISE ALL WIND DESIGN
 PRESSURES AS REQUIRED.
  
 12-PLYWOOD SHEATHING NAILING SCHEDULE ON SHEET S-5 :
 REVISE ROOF SHEATHING NAILING SPECIFICATIONS TO COMPLY
 WITH NEW 2020 FBC-RESIDENTIAL SPECIFICATIONS. REVISE
 TYPE, SIZE AND SPACING. NOTE: NEED TO USE RING SHANK
 NAILS. ROOF SHEATHING NEEDS TO BE NAILED AT 4 INCHES
 O.C. IN THE FIELD AND EDGES AS REQUIRED BY SEC.
 R803.2.3.1 AND TABLE R803.2.3.1 FBC-RESIDENTIAL.
 NOTE: REVISE SPECIFICATIONS OR PROVIDE CALCULATIONS
 SHOWING THAT SPECIFIED NAIL TYPE AND SPACING MATCHES OR
 EXCEEDS TABLE R803.2.3.1 FBC-RESIDENTIAL MINIMUM
 REQUIREMENTS.
 SEC. 107.2.1.2 CITY AMENDMENTS.
  
 13- ENERGY CALCULATIONS (MAIN HOUSE):
 A)THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY AT THE OWNER/AGENT LINE AT THE BOTTOM OF FORM
 THAT THE BUILDING IS IN COMPLIANCE WITH THE CODE, AS
 PER SECTION 553.907, FLORIDA STATUTES, PRIOR TO
 RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION AS REQUIRED BY SECTION R103.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER'S NAME, BUILDER'S NAME. SEC.
 R101.5.1.1.2 FBC- ENERGY CONSERVATION.
  
 C)ENERGY CALCULATIONS ARE TAKEN THE CEILING FAN CREDIT.
 PLANS DON'T SHOW CEILING FANS FOR ALL REQUIRED ROOMS.
 REVISE AS REQUIRED TO MATCH PLANS. IF TAKING THE
 CEILING FAN CREDIT, THEN PLANS NEED TO SHOW CEILING FAN
 AND SIZE IN ALL THE ROOMS AS REQUIRED BY TABLE R405.7.6
 FBC-ENERGY CONSERVATION
 NOTE: SEE SIZE AND NUMBER OF FANS REQUIRED BASED ON
 ROOM SIZE.
  
 D)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC-ENERGY
 CONSERVATION.
  
 14- ENERGY CALCULATIONS (GUEST HOUSE):
 A)THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER
 AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL
 CERTIFY AT THE OWNER/AGENT LINE AT THE BOTTOM OF FORM
 THAT THE BUILDING IS IN COMPLIANCE WITH THE CODE, AS
 PER SECTION 553.907, FLORIDA STATUTES, PRIOR TO
 RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR
 RENOVATION AS REQUIRED BY SECTION R103.1.1.2 FBC-ENERGY
 CONSERVATION.
  
 B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING BUILDER'S NAME. SEC. R101.5.1.1.2 FBC- ENERGY
 CONSERVATION.
  
 C)ENERGY CALCULATIONS ARE TAKEN THE CEILING FAN CREDIT.
 PLANS DON'T SHOW CEILING FANS FOR ALL REQUIRED ROOMS.
 REVISE AS REQUIRED TO MATCH PLANS. IF TAKING THE
 CEILING FAN CREDIT, THEN PLANS NEED TO SHOW CEILING FAN
 AND SIZE IN ALL THE ROOMS AS REQUIRED BY TABLE R405.7.6
 FBC-ENERGY CONSERVATION
 NOTE: SEE SIZE AND NUMBER OF FANS REQUIRED BASED ON
 ROOM SIZE.
  
 D)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC-ENERGY
 CONSERVATION.
  
 15- PRODUCT APPROVALS DEFERRED SUBMITTAL: AS REQUESTED
 BY THE OWNER THE PRODUCT APPROVALS WILL BE SUBMITTED
 LATER.
 NOTE: SUBMIT FOR REVIEW AFTER THE PERMIT IS ISSUED BUT
 BEFORE INSPECTIONS TO AVOID CONFLICTS/DELAYS.
 A)EXTERIOR DOORS AS SHOWN ON PLANS. (NOTE: PLEASE
 IDENTIFY EACH PRODUCT APPROVAL. FOR EXAMPLE ENTRY DOOR,
 GARAGE SWING DOOR, ETC.)
 B)WINDOWS AS SHOWN ON PLANS.
 C)WINDOWS AND DOORS MULLIONS (NOTE: NEED TO SPECIFY
 MULLION SIZE TO VERIFY PRESSURES. SEC. R301.2.1
 FBC-RESIDENTIAL).
 D)HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE
 IMPACT GLAZING. AND, PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE CITY SAMPLE.
 E)ROOF TILE AND CLEARLY MARK ADHESIVE PADDY SIZE TO BE
 USED AS REQUIRED BY CITY POLICY FOR ALL ROOFING PERMITS
 TO VERIFY COMPLIANCE WITH THE DESIGN PRESSURES OF SEC
 R301.2.1 FBC-RESIDENTIAL.
 F)ROOFING UNDERLAYMENT SPECIFIED ON PLANS.
 G)ROOF TILE ADHESIVE ( IF USED) LISTED IN ROOF TILE
 PRODUCT APPROVAL.
 H)HIP & RIDGE METAL SUPPORT TO BE USED.
 L)BALCONY UNDERLAYMENT SPECIFIED ON PLANS TO RECEIVE
 TILE.
 M)FLOOD VENTS SPECIFIED BY THE DESIGNER OF RECORD.
 N)OVERHEAD GARAGE DOORS.
  
 16- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 17- HOUSE IS DESIGNED WITH UNVENTED ATTIC. ARCHITECT IS
 SPECIFYING R-30 ICYNENE SPRAY INSULATION. PROVIDE ICC
 EVALUATION REPORT FOR THE ICYNENE R-30 INSULATION TO
 VERIFY COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL.
 NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN
 WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
 NOTE: THIS COULD BE A DEFERRED SUBMITAL ALSO.
  
 18- WINDOW FALL PROTECTION SHALL BE PROVIDED ON SECOND
 FLOOR WINDOWS WHERE THE TOP OF THE WINDOW SILL OF AN
 OPERABLE WINDOW IS LOCATED LESS THAN 24" ABOVE THE
 FINISHED FLOOR . SEC. R312.2 FBC RESIDENTIAL.
 NOTE: CLEARLY INDICATE THE WINDOW SILL HEIGHT OF SECOND
 FLOOR WINDOWS AND SPECIFY TYPE OF WINDOW FALL
 PROTECTION IF REQUIRED.
  
 19- SPECIFY CARBON MONOXIDE ALARMS BY ALL BEDROOMS AS
 REQUIRED BY SEC. R315.1 FBC-RESIDENTIAL.
 NOTE: GUEST SUITE NEEDS ONE.
  
 20- PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR
 PERGOLAS OR TRELLIS SHOWN ON THE MAIN HOUSE AND
 SEPARATE GUEST HOUSE. SPECIFY ALL FRAMING MEMBERS AND
 CONNECTORS. SEC. R301.1 FBC-RESIDENTIAL.
  
 21- DESIGNER OF RECORD NEEDS TO DEPICT THE BUILDING
 THERMAL ENVELOPE. NEED TO SPECIFY INSULATION MATERIALS
 AND THEIR R-VALUES.(ROOF, WALLS, RAISED FLOOR ABOVE
 GARAGE, ETC.) AS REQUIRED BY SEC. R103.2 FBC-ENERGY
 CONSERVATION.
 NOTE: SECTION 1 ON SHEET A-7.2 DOESN'T SHOW INSULATION
 ABOVE GARAGE.
  
 22- HANDRAILS AND GUARDRAILS: DESIGNER OF RECORD TO
 PROVIDE THE DETAILS AND SPECIFICATIONS FOR THE
 CONSTRUCTION OF THE HANDRAILS AND GUARDRAILS AS
 REQUIRED BY TABLE R301.5, SEC. R311.7.8 AND SEC. R312.1
 FBC-RESIDENTIAL.
 (SUBSEQUENT SHOP DRAWINGS ARE TO CONFIRM THAT DESIGN
 DETAILS AND SPECIFICATIONS ARE MET).
 NOTE: GUARDRAIL SECTIONS/DETAILS ON SHEETS A-6.3,
 A-7.1,A-7.2, A-7.3 SHOW 4" DIMENSION AT THE BOTTOM OF
 THE GUARDRAIL. THIS DOESN'T COMPLY WITH THE REQUIREMENT
 THAT A 4" SPHERE CANNOT PASS THRU. REVISE AS REQUIRED.
 ALSO, A 6" SPHERE CANNOT PASS THRU THE TRIANGULAR
 OPENINGS ON THE STAIRS. PROVIDE INFORMATION AS
 REQUIRED.
  
 23- SHEET C-1: ENGINEER DIGITAL SIGNATURE DOESN'T SEEM
 TO COMPLY WITH THE REQUIREMENTS OF SEC. 61G15-23.004.
 IT DOESN'T HAVE A TITLE BLOCK, THE REQUIRED TEXT BOX
 LANGUAGE. IT ONLY SHOWS DIGITALLY SIGNED BY RICHARD V
 REIKENIS AND THE DATE. IT DOESN'T IDENTIFY THE
 ENGINEER'S LICENSE NUMBER.
 SEE SEC. 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING
 AND SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS AND RESUBMIT
 DRAWING WITH VERIFIABLE DIGITAL SIGNATURE.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-06-05 Cont ID  
Sent By rperdomo Date 2023-06-05 Time 14:39 Rev Time 0.00
Received By rperdomo Date 2023-06-05 Time 14:25 Sent To  
Notes
2023-06-05 14:42:05FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: APPROVED, SEE COMMENTS BELOW
  
 1. THIS ELECTRICAL REVIEW IS ONLY FOR THE MAIN HOUSE.
 ACCESSORY STRUCTURE REQUIRES A SEPARATE PERMIT NUMBER.
  
 END OF COMMENTS
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER/ INSPECTOR
 561-805-6738
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-04-13 Cont ID  
Sent By rperdomo Date 2023-04-13 Time 13:40 Rev Time 0.00
Received By rperdomo Date 2023-04-13 Time 12:12 Sent To  
Notes
2023-04-13 13:39:39FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. REVIEW ELECTRICAL NOTES FOR NFPA 70 2017 EDITION.
  
 2. DISCONNECTING MEANS FOR A/C EQUIPMENT PER NEC 440.14
 OR IRC E4101.5
 DISCONNECTING MEANS ARE REQUIRED TO BE LOCATED
 ???WITHIN SIGHT FROM AND READILY ACCESSIBLE??? FROM THE
 AIR-CONDITIONING EQUIPMENT.
  
 3. THIS ELECTRICAL REVIEW IS ONLY FOR THE MAIN HOUSE.
 ACCESSORY STRUCTURE REQUIRES A SEPARATE PERMIT NUMBER.
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2023-06-01 Cont ID  
Sent By lquinone Date 2023-06-01 Time 19:54 Rev Time 0.00
Received By lquinone Date 2023-06-01 Time 19:54 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2023-04-12 Cont ID  
Sent By lquinone Date 2023-04-12 Time 15:12 Rev Time 0.00
Received By lquinone Date 2023-04-12 Time 15:12 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2023-05-31 Cont ID  
Sent By ccole Date 2023-05-31 Time 07:59 Rev Time 0.00
Received By ccole Date 2023-05-30 Time 16:49 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-04-12 Cont ID  
Sent By ccole Date 2023-04-12 Time 15:01 Rev Time 0.00
Received By ccole Date 2023-04-12 Time 14:50 Sent To  
Notes
2023-04-12 15:01:281ST REVIEW FBC-2020 RES. GAS
 PERMIT- 23021503
 54/12/2023
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A-1.1: THE ACCESSORY BUILDING GWH EXHAUST
 APPEARS TO BE WITHIN THE 4 FT. MINIMUM TO THE OPERABLE
 AND THE FLOOD VENT OPENING- SEC. G2427.8 (2) FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop HIST HISTORICAL
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2023-07-11 Cont ID  
Sent By vbroglia Date 2023-07-11 Time 10:14 Rev Time 0.00
Received By vbroglia Date 2023-07-11 Time 10:14 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2023-05-11 Cont ID  
Sent By fmittner Date 2023-05-11 Time 08:59 Rev Time 0.00
Received By fmittner Date 2023-05-11 Time 08:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By lmarchan Date 2023-07-25 Time 16:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-07-11 Cont ID  
Sent By vbroglia Date 2023-07-11 Time 10:14 Rev Time 0.00
Received By vbroglia Date 2023-05-26 Time 09:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-05-17 Cont ID  
Sent By shill Date 2023-05-17 Time 19:19 Rev Time 0.00
Received By shill Date 2023-04-04 Time 11:25 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-04-18 Cont ID  
Sent By jgomez Date 2023-04-18 Time 15:20 Rev Time 0.00
Received By jgomez Date 2023-04-18 Time 15:20 Sent To  
Notes
2023-04-18 15:22:50IMPACT FEES QUESTIONNAIRE WAS UPLOADED TO PROJECTDOX.
 ONCE PERMIT IS APPROVED, THE PERMIT LIBRARIAN WILL BE
 NOTIFIED TO EMAIL THE COUNTY FOR IMPACT FEES
 ASSESSMENT. JG.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2023-06-15 Cont ID  
Sent By hmoser Date 2023-06-15 Time 16:37 Rev Time 0.00
Received By hmoser Date 2023-06-15 Time 14:19 Sent To  
Notes
2023-06-15 16:37:30PASS PROVISO
 1) THE MECHANICAL REVIEW IS ONLY FOR THE MAIN HOUSE.
 ACCESSORY STRUCTURE REQUIRE SEPERATE PERMIT. SECTION
 105.1 FBC 2020
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-04-18 Cont ID  
Sent By medwards Date 2023-04-18 Time 07:16 Rev Time 0.00
Received By medwards Date 2023-04-18 Time 07:16 Sent To  
Notes
2023-04-18 07:16:221ST REVIEW FMC
 PERMIT: 23021503
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
  
 MAIN HOUSE REVIEW:
  
 1) THE MANUAL J CALCULATIONS PAGE 2 OF 10 FOR THE MAIN
 HOUSE INDICATES A TOTAL COOLING LOAD OF 78,570 AND
 6.55-TONS FOR THE COMBINED UNIT SIZE FOR A TOTAL SQUARE
 FOOTAGE OF 4,687. MANUAL J INDICATES THAT SYSTEM 1 IS A
 3.65-TON UNIT AND SYSTEM 2 REQUIRES A 2.90-TONS. SHEET
 M.2 INDICATES SYSTEM 1 TO BE A 5-TON SYSTEM AND SYSTEM
 2 TO BE A 4-TON SYSTEM. PLEASE SHOW HOW EACH OF THESE
 UNITS WILL MEET THE 1.15 TIMES GREATER THAN THE DESIGN
 COOLING LOAD. FEC R403.7.1.2
  
 2) PLEASE ADD A NOTE TO SHEET M.1 INDICATING THAT THE
 LOUVER FOR THE MAKE-UP AIR FOR THE HOOD SHALL BE
 PROTECTED WITH A SCREEN. FRC R303.6
  
 3) SHEET M.2: PROVIDE AN EXHAUST FAN IN THE TUB AREA OF
 THE PRIMARY BATH. FRC R303.3
  
 GARAGE/GUEST HOUSE REVIEW:
  
 1) THE GARAGE/GUEST HOUSE WILL REQUIRE A SEPARATE
 PERMITS.
  
 2) EXPLAIN THE ARROWS FROM EXTERIOR WALL TO MECHANICAL
 UNIT IN ATTIC ABOVE KITCHEN.
  
 3) INDICATE THE MOUNTING HEIGHT OF THE CONDENSING UNIT
 BECAUSE OF THE FLOOD PLAIN.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2023-07-06 Cont ID  
Sent By jgomez Date 2023-07-06 Time 09:39 Rev Time 0.00
Received By jgomez Date 2023-07-06 Time 09:37 Sent To  
Notes
2023-07-06 09:40:59NFIP REVIEW:
  
 1- THIS BUILDING IS GOING TO BE BUILT IN A AE FLOOD
 ZONE WITH THE BASE FLOOD BFE: 6 FEET BASED ON NAVD
 1988.
 CITY OF WEST PALM BEACH ORDINANCE REQUIRES A TWO (2)
 FOOT FREE BOARD ABOVE THE BASE FLOOD ELEVATION (SEC.
 18-284 CITY ORDINANCE NO. 4729-17).
 DESIGNER OF RECORD NEEDS TO SPECIFY THE PROPOSED FINISH
 ELEVATIONS, INCLUDING ALL EQUIPMENT SERVING THE TWO
 BUILDINGS.
  
 DURING THE PERMITTING/CONSTRUCTION OF THIS STRUCTURE
 THREE DIFFERENT FLOOD ELEVATION CERTIFICATES WILL BE
 REQUIRED (SEC. 107.3.5.1.1 CITY AMENDMENTS):
 A) CONSTRUCTION DRAWINGS.
 B) BUILDING UNDER CONSTRUCTION.
 C) FINISHED CONSTRUCTION.
  
 NOTE:
 NEED TO PROVIDE THE CONSTRUCTION DRAWINGS ELEVATION
 CERTIFICATE NOW FOR REVIEW.
 ALSO, NEED TO PROVIDE SURVEY TO VERIFY ELEVATIONS
 SPECIFIED ON ELEVATION CERTIFICATE.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2023-04-18 Cont ID  
Sent By jgomez Date 2023-04-18 Time 17:02 Rev Time 0.00
Received By jgomez Date 2023-04-18 Time 17:01 Sent To  
Notes
2023-04-18 17:07:29NFIP REVIEW:
  
 1- THIS BUILDING IS GOING TO BE BUILT IN A AE FLOOD
 ZONE WITH THE BASE FLOOD BFE: 6 FEET BASED ON NAVD
 1988.
 CITY OF WEST PALM BEACH ORDINANCE REQUIRES A TWO (2)
 FOOT FREE BOARD ABOVE THE BASE FLOOD ELEVATION (SEC.
 18-284 CITY ORDINANCE NO. 4729-17).
 DESIGNER OF RECORD NEEDS TO SPECIFY THE PROPOSED FINISH
 ELEVATIONS, INCLUDING ALL EQUIPMENT SERVING THE TWO
 BUILDINGS.
 NOTE: MISSING INFORMATION FOR CONDENSING UNIT #3 AND
 GUEST HOUSE EQUIPMENT.
  
 DURING THE PERMITTING/CONSTRUCTION OF THIS STRUCTURE
 THREE DIFFERENT FLOOD ELEVATION CERTIFICATES WILL BE
 REQUIRED (SEC. 107.3.5.1.1 CITY AMENDMENTS):
 A) CONSTRUCTION DRAWINGS.
 B) BUILDING UNDER CONSTRUCTION.
 C) FINISHED CONSTRUCTION.
  
 NOTE:
 NEED TO PROVIDE THE CONSTRUCTION DRAWINGS ELEVATION
 CERTIFICATE NOW FOR REVIEW.
 ALSO, NEED TO PROVIDE SURVEY AND FLOOD VENTS PRODUCT
 APPROVAL SPECIFIED BY THE ARCHITECT TO VERIFY
 ELEVATIONS AND NET FLOOD VENT NET AREA SPECIFIED ON
 ELEVATION CERTIFICATE.
  
 2-DESIGNER OF RECORD TO SPECIFY SIZE OF FLOOD VENTS.
 SEC. R322.2.2 FBC-RESIDENTIAL.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-05-31 Cont ID  
Sent By ccole Date 2023-05-31 Time 07:59 Rev Time 0.00
Received By ccole Date 2023-05-30 Time 16:49 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2023-04-12 Cont ID  
Sent By ccole Date 2023-04-12 Time 14:50 Rev Time 0.00
Received By ccole Date 2023-04-12 Time 14:00 Sent To  
Notes
2023-04-12 14:51:11PLUMBING PASSED FOR MAIN HOUSE AND ACCESSORY STRUCTURE.

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2023-07-06 Cont ID  
Sent By rgathrig Date 2023-07-06 Time 14:39 Rev Time 0.00
Received By rgathrig Date 2023-07-06 Time 14:38 Sent To  
Notes
2023-07-06 14:41:53PRIVATE PROVIDER DOCUMENT REVIEW FAILED
 THE APPLICATION HAS THE PRIVATE PROVIDER INSPECTIONS
 BOX CHECKED,
 THERE ARE NO PRIVATE PROVIDER DOCUMENTS UPLOADED.
 NOTICE TO BUILDING OFFICIAL, LICENSE INFORMATION,
 CERTIFICATE OF INSURANCE
 F.S. 553.791
  
 RICHARD GATHRIGHT
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2023-04-18 Cont ID  
Sent By jgomez Date 2023-04-18 Time 17:11 Rev Time 0.00
Received By jgomez Date 2023-04-18 Time 17:11 Sent To  
Notes
2023-04-18 17:12:411- NEED TO PROVIDE ALL THE ROOFING INFORMATION WITH THE
 ROOFING SUB-PERMIT. JG.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-07-06 Cont ID  
Sent By jgomez Date 2023-07-06 Time 09:43 Rev Time 0.00
Received By jgomez Date 2023-07-06 Time 09:42 Sent To  
Notes
2023-07-06 09:45:28DIGITAL SIGNATURE REVIEW:
  
 1- DRAINAGE PLAN DRAWING C-1: ENGINEER'S DIGITAL
 SIGNATURE DOESN'T COMPLY WITH THE REQUIREMENTS OF FBPE.
 NEED A SEPARATE TEXT BOX WITH THE TEXT BOX LANGUAGE
 IDENTICAL TO THE SAMPLES SHOWN BY FBPE.
 SEE FBPE.ORG/LEGAL/SIGNING-AND-SEALING-ENGINEERING-DOCU
 MENTS/ AND REVISE DIGITAL SIGNATURE AS REQUIRED.
 NOTE: THIS WAS CONFIRMED WITH THE FBPE INVESTIGATOR.
  
 SEC. 61G15-23.004 F.A.C. PROCEDURES FOR DIGITALLY
 SIGNING AND SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-04-18 Cont ID  
Sent By jgomez Date 2023-04-18 Time 17:50 Rev Time 0.00
Received By jgomez Date 2023-04-18 Time 17:12 Sent To  
Notes
2023-04-18 17:51:18SIGNATURE REVIEW:
  
 1- SHEET C-1: ENGINEER DIGITAL SIGNATURE DOESN'T SEEM
 TO COMPLY WITH THE REQUIREMENTS OF SEC. 61G15-23.004.
 IT DOESN???T HAVE A TITLE BLOCK, THE REQUIRED TEXT BOX
 LANGUAGE. IT ONLY SHOWS DIGITALLY SIGNED BY RICHARD V
 REIKENIS AND THE DATE. IT DOESN'T IDENTIFY THE
 ENGINEER'S LICENSE NUMBER.
  
 SEE SEC. 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING
 AND SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS
 AND RESUBMIT.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
2023-04-18 07:17:25MECHANICAL DIGITAL SIGNATURES APPROVED ME.
2023-04-12 15:02:20PLUMBING & GAS (P) PLANS DIG/SIGS PASSED.

Review Stop Z ZONING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2023-07-10 Cont ID  
Sent By vbroglia Date 2023-07-10 Time 16:51 Rev Time 0.00
Received By vbroglia Date 2023-07-10 Time 16:51 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2023-05-11 Cont ID  
Sent By fmittner Date 2023-05-11 Time 08:59 Rev Time 0.00
Received By fmittner Date 2023-05-11 Time 08:59 Sent To  
Notes
***NONE***