| Plan Review Stops For Permit 23021403 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
2 |
Status |
P |
Date |
2023-04-07 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-06 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-06 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
2023-03-21 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-03-21 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-03-21 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2023-03-21 10:59:22 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23021403 | | | | | | REVIEWED: MARCH 21, 2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENT: | | | | | | ASBESTOS REVIEW: | | | | | | FAILED PLAN REVIEW: | | | | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | | -RENOVATION.HTML | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2023-04-07 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-07 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-07 |
Time |
07:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-28 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-03-28 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-03-28 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2023-03-28 08:21:07 | ALL COMMENTS MUST BE ADDRESSED FIRST. | | | PLEASE RESPOND ACCORDINGLY TO EACH COMMENT. THANK YOU! | | | | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-04-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-04-13 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-04-13 |
Time |
08:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-03-14 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-03-14 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2023-03-14 14:11:58 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) DRINKING FOUNTAIN TO BE GFCI PROTECTED 422.5 | | | | | | 2) CIRCUIT FOR DRINKING FOUNTAIN AND GARAGE DOOR OPENER | | | ARE THE SAME CIRCUIT. 210.23(A)(1,2) | | | | | | 3) TWO OF THE AC UNITS ARE ON THE SAME CIRCUIT. 210.23 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-03-01 |
|
|
Cont ID |
|
| Sent By |
cwalker |
Date |
2023-03-01 |
Time |
|
Rev Time |
|
| Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2023-03-01 10:08:49 | FIRE PROVISO COMMENTS: | | | | | | (1) AN EVALUATION OF THE FIRE SPRINKLER SYSTEM SHALL BE | | | CONDUCTED BY A PROPERLY LICENSED FIRE SPRINKLER | | | CONTRACTOR TO ENSURE THE EXISTING FIRE SPRINKLER SYSTEM | | | IS ADEQUATE FOR THE PROPOSED OCCUPANCY AND COMMODITY | | | CLASSIFICATION. | | | | | | (2) ANY WORK PERFORMED ON ANY LIFE SAFETY SYSTEM (FIRE | | | SPRINKLER AND/OR FIRE ALARM) SHALL BE PERFORMED BY | | | PROPERLY LICENSED CONTRACTORS UNDER SEPARATE PERMITS | | | AND SHOP DRAWINGS. | | | | | | (3) THE EXISTING LIFE SAFETY SYSTEMS (FIRE SPRINKLER | | | AND/OR FIRE ALARM) SHALL REMAIN OPERATIONAL DURING ALL | | | PHASES OF DEMOLITION AND CONSTRUCTION. | | | | | | (4) ANY IMPAIRMENT TO ANY LIFE SAFETY SYSTEM (FIRE | | | SPRINKLER AND/OR FIRE ALARM) THAT EXCEEDS 4 CONTINUOUS | | | HOURS IN DURATION WILL REQUIRE THE IMPLEMENTATION OF A | | | FIRE WATCH. | | | | | | (5) THE PLAN SUBMITTAL DID NOT INDICATE THE LOCATION OF | | | THE NEAREST WATER SOURCE TO THE FIRE DEPARTMENT | | | CONNECTION OF THE EXISTING FIRE SPRINKLER SYSTEM. THE | | | LOCATION MUST MEET THE REQUIREMENTS OF NFPA 13. | | | | | | C. WALKER | | | | | | 561-804-4762 | | | | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-04-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-04-14 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-04-05 |
Time |
16:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-28 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-03-28 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-02-28 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2023-03-28 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-03-28 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-03-28 |
Time |
08:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2023-04-14 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-04-14 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-04-14 |
Time |
09:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-03-07 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-03-07 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2023-03-07 10:58:04 | 1ST REVIEW FMC | | | PERMIT: 23021403 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE ENERGY CALCULATIONS DO NOT SHOW THE NEW OVER | | | HEAD DOOR IN THE CALCULATIONS. PROVIDE ENERGY | | | CALCULATIONS INCLUDING THE OVERHEAD DOOR. FEC C402.5.4 | | | AND C402.5.6 | | | | | | 2) PROVIDE THE SMOKE DETECTORS IN THE SUPPLY DUCT FOR | | | EACH OF THESE RTU???S. THEY SHARE THE SUPPLY SO ARE | | | REQUIRED FMC 606.2.2 | | | | | | 3) PROVIDE A ROOF DRAWING INDICATING THE LOCATIONS OF | | | THE RTU???S AND GUARD PROTECTION IF REQUIRED BY FMC | | | 304.11 | | | | | | 4) INDICATE THE LOCATION OF THE ACCESS FOR THE RTU???S | | | ON THE ROOF DRAWING. FMC 306.5 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-04-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-04-10 |
Time |
16:16 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-04-10 |
Time |
16:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-03-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-03-07 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-03-07 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2023-03-07 09:56:10 | 1ST REVIEW FBC-2020 PLUMBING | | | PERMIT- 23021403 | | | 3/7/2023 | | | | | | CODES IN EFFECT: | | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET P-1: BASED ON THE PLANS IT APPEARS THE SCOPE | | | OF PLUMBING WORK IS TO REPLACE THE WATER HEATER, THE | | | RESTROOM FIXTURES, AND INSTALL A NEW HOSE BIB. PLEASE | | | CONFIRM AND PROVIDE NOTES OR DETAILS ON THE PLAN | | | SPECIFYING ACCESSIBLE WATER CLOSETS AND LAVATORIES WILL | | | BE INSTALLED- SECS. (213.1- 213.3.4), (604.1- 604.4), & | | | (606.1- 606.5) FBC ACC. | | | | | | 2) P-1: THE SANITARY RISER SHOWS EXISTING DRAIN AND | | | VENT PIPING HOWEVER PLEASE NOTE THE FIXTURE DRAIN FOR | | | THE DRINKING FOUNTAINS SHOULD NOT BE CONNECTING TO THE | | | WET VENT FOR THE BATHROOM FIXTURES, AND SHOULD BE | | | MAKING CONNECTION DOWNSTREAM OF THE VENT- SEC. 912.1 | | | FBC P. | | | | | | 3) P-1: THE WATER HEATER DETAIL SHOWS A MOP SINK BELOW | | | THE UNIT HOWEVER NO PIPING FOR THE FIXTURE IS SHOWN IN | | | THE RISER DRAWINGS. PLEASE NOTE THE MOP SINK IS A | | | REQUIRED FIXTURE FOR STORAGE OCCUPANCIES- TABLE 403.1 | | | FBC P. | | | | | | 4) P-1: A MEANS OF LIMITING THE HOT WATER TEMPERATURE | | | DELIVERY OTHER THAN THE WATER HEATER THERMOSTAT IS | | | REQUIRED. PLEASE PROVIDE A MASTER THERMOSTATIC MIXING | | | VALVE AND REVISE THE WATER HEATER DETAIL TO SHOW THE | | | LOCATION OF THE DEVICE AND PIPING CONNECTIONS- SEC. | | | 607.1.1 FBC P. | | | | | | 5) P-1: TEMPERED WATER SHALL BE DELIVERED FROM THE | | | LAVATORIES THROUGH A WATER TEMPERATURE LIMITING DEVICE | | | THAT CONFORMS TO ASSE 1070- SECS. 419.5 & 607.1.2 FBC | | | P. | | | | | | 6) P-1: THE 1/2-INCH HW SUPPLY PIPES TO THE PUBLIC | | | LAVATORIES SHALL NOT EXCEED 2FT. TO TERMINATION FROM | | | THE HW SOURCE PER TABLE C404.5.1 FBC ENERGY. IN ORDER | | | TO MEET COMPLIANCE, PROVIDE EITHER A RECIRCULATION PUMP | | | AND LINE, OR POINT OF USE WATER HEATERS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-04-18 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-04-07 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-04-07 |
Time |
07:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-03-14 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-03-14 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2023-03-21 11:03:41 | SURVEY DIGITAL SIGNATURE AND SEAL FAILED | | 2023-03-07 10:58:58 | MECHANICAL DIGITAL SIGNATURE APPROVED ME | | 2023-03-07 09:06:32 | PLUMBING PLAN PASSED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-21 |
|
|
Cont ID |
|
| Sent By |
ASangele |
Date |
2023-03-21 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-03-21 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|