| Plan Review Stops For Permit 23021382 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2023-04-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-04-06 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-04-06 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-03-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-31 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-31 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2023-03-31 09:37:42 | RESIDENTIAL (R3)THIRD BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #23021382 | | | 10241 HERONWOOD LN | | | | | | PREVIOUS COMMENT: | | | 1- REVISE NOTE ON SURVEY. THE GENERATOR SHALL BE | | | LOCATED A MINIMUM OF 10 FT. FROM AIR INTAKES INTO THE | | | BUILDING- SEC. R303.5.1 FBC RES. PLEASE CORRECT THE | | | NOTE INDICATING 5 FT. | | | | | | RESPONSE: | | | REPEAT COMMENT THREE TIMES. NOT ADDRESSED. | | | | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-03-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-29 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-29 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2023-03-29 09:31:49 | RESIDENTIAL (R3)SECOND BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #23021382 | | | 10241 HERONWOOD LN | | | | | | PREVIOUS COMMENT: | | | 1- REVISE NOTE ON SURVEY. THE GENERATOR SHALL BE | | | LOCATED A MINIMUM OF 10 FT. FROM AIR INTAKES INTO THE | | | BUILDING- SEC. R303.5.1 FBC RES. PLEASE CORRECT THE | | | NOTE INDICATING 5 FT. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | | | | PREVIOUS COMMENT: | | | 2- GENERATOR CONCRETE PAD ENGINEERING HAS A COPY OF THE | | | ENGINEER'S DIGITAL SIGNATURE. NEED ORIGINAL | | | SEAL/SIGNATURE WHEN SUBMITTED FOR PUBLIC RECORDS. | | | ELECTRONIC SUBMITTALS NEED VERIFIABLE DIGITAL | | | SIGNATURE. | | | | | | ENGINEERS | | | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | RESPONSE: | | | REPEAT COMMENT. PAD ENGINEERING UPLOADED ON 03/24/23 IS | | | A COPY. NEED DOCUMENT WITH VERIFIABLE DIGITAL | | | SIGNATURE. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-23 |
Time |
18:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-23 |
Time |
18:36 |
Sent To |
|
|
| Notes |
| 2023-03-23 18:54:16 | RESIDENTIAL (R3)BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #23021382 | | | 10241 HERONWOOD LN | | | | | | 1- REVISE NOTE ON SURVEY. THE GENERATOR SHALL BE | | | LOCATED A MINIMUM OF 10 FT. FROM AIR INTAKES INTO THE | | | BUILDING- SEC. R303.5.1 FBC RES. PLEASE CORRECT THE | | | NOTE INDICATING 5 FT. | | | | | | 2- GENERATOR CONCRETE PAD ENGINEERING HAS A COPY OF THE | | | ENGINEER'S DIGITAL SIGNATURE. NEED ORIGINAL | | | SEAL/SIGNATURE WHEN SUBMITTED FOR PUBLIC RECORDS. | | | ELECTRONIC SUBMITTALS NEED VERIFIABLE DIGITAL | | | SIGNATURE. | | | | | | ENGINEERS | | | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-03-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-03-10 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-03-10 |
Time |
09:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2023-03-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-03-27 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-03-27 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2023-03-27 12:12:26 | GAS UNDER PERMIT 23020704. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-03-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-03-24 |
Time |
07:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-03-24 |
Time |
06:50 |
Sent To |
|
|
| Notes |
| 2023-03-24 07:05:56 | 1ST REVIEW FBC-2020 RES. FUEL GAS | | | PERMIT- 23021382 | | | 3/24/2023 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. PLEASE REVIEW THE COMMENTS | | | AND NOTE THAT GAS FOR THE GENERATOR CAN BE UNDER A | | | SEPARATE PERMIT BY REQUEST. | | | | | | 1) A GAS RISER DRAWING IS REQUIRED PER SEC. 107.3.5.3 | | | WPB. PROVIDE A COMPLETE GAS RISER DRAWING THAT INCLUDES | | | THE NEW PIPING TO THE GENERATOR AND THE EXISTING THE | | | GAS PIPING AND APPLIANCES AT THE RESIDENCE- SECTION | | | G2412.3 & G2412.4 FBC RES. REFER TO FBC RES. CHAPTER 24 | | | FUEL GAS- THE RISER SHALL INDICATE: | | | A) TYPE OF GAS- NATURAL OR LP. | | | B) DELIVERY PRESSURE AT THE METER. | | | C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS. | | | D) TYPES AND SIZES OF PIPING. | | | E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER | | | TO THE MOST REMOTE APPLIANCE OUTLET. | | | F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. | | | G) LOCATIONS OF REGULATORS AND OUTLET PRESSURES. | | | H) LOCATIONS OF SHUT OFF VALVES. | | | I) PIPE SIZING TABLES | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-04-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-04-06 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-04-03 |
Time |
11:11 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-03-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-31 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-30 |
Time |
10:32 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-03-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-29 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-26 |
Time |
07:32 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-03-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-02-28 |
Time |
10:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2023-03-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-03-27 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-03-27 |
Time |
12:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-24 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-03-24 |
Time |
07:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-03-24 |
Time |
06:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-03-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-31 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-31 |
Time |
09:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2023-03-29 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-29 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-29 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2023-03-29 09:32:14 | SIGNATURE REVIEW: | | | | | | PREVIOUS COMMENT: | | | 1- GENERATOR CONCRETE PAD ENGINEERING HAS A COPY OF THE | | | ENGINEER'S DIGITAL SIGNATURE. NEED ORIGINAL | | | SEAL/SIGNATURE WHEN SUBMITTED FOR PUBLIC RECORDS. | | | ELECTRONIC SUBMITTALS NEED VERIFIABLE DIGITAL | | | SIGNATURE. | | | | | | ENGINEERS | | | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | RESPONSE: | | | REPEAT COMMENT. PAD ENGINEERING UPLOADED ON 03/24/23 IS | | | A COPY. NEED DOCUMENT WITH VERIFIABLE DIGITAL | | | SIGNATURE. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-03-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-03-23 |
Time |
18:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-03-23 |
Time |
18:43 |
Sent To |
|
|
| Notes |
| 2023-03-23 18:55:32 | SIGNATURE REVIEW: | | | | | | 1- GENERATOR CONCRETE PAD ENGINEERING HAS A COPY OF THE | | | ENGINEER'S DIGITAL SIGNATURE. NEED ORIGINAL | | | SEAL/SIGNATURE WHEN SUBMITTED FOR PUBLIC RECORDS. | | | ELECTRONIC SUBMITTALS NEED VERIFIABLE DIGITAL | | | SIGNATURE. | | | | | | ENGINEERS | | | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND | | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | | | 2023-03-10 11:41:05 | ELECTRICAL PAGE SIGNATURE IS APPROVED JLEAHY |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2023-04-06 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-04-06 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-04-06 |
Time |
15:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2023-03-07 |
|
|
Cont ID |
|
| Sent By |
VBroglia |
Date |
2023-03-07 |
Time |
10:13 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-03-07 |
Time |
10:13 |
Sent To |
|
|
| Notes |
|
|