Plan Review Details - Permit 23021250
| Plan Review Stops For Permit 23021250 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-04-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-04-03 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-04-03 |
Time |
13:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-03-17 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-03-17 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-03-17 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2023-03-17 09:19:46 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, THE SCHEDULE SHOWS THE 5/16" ULTRACON & | | | TAPCON ANCHOR SPACING AT 18" ON CENTER, WHERE AS THE | | | PRODUCT APPROVAL SHEET 7 OF 14, TABLE A2, | | | INDICATES(CIRCLED) 8" ON CENTER ANCHOR SPACING. PLEASE | | | CORRECT THE SCHEDULE TO MATCH THE PRODUCT APPROVAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-08 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-03-08 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-03-08 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2023-03-08 15:35:43 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | BUILDING REVIEW DENIED: | | | | | | FBC B 107.2.1, MISSING THE NEW INSTALLATION SCHEDULE. | | | PLEASE INCLUDE A REVISED INSTALLATION SCHEDULE FOR THE | | | TWO OPENINGS. THE NEW SCHEDULE NEEDS TO CORELATE WITH | | | THE DETAILS FROM THE NEW PRODUCT APPROVAL # FL29518. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-04-03 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-04-03 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-03-17 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-03-17 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-03-17 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-03-14 |
Time |
16:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-08 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-03-08 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-03-06 |
Time |
11:13 |
Sent To |
|
|
| Notes |
|
|
|