Plan Review Details - Permit 23021238
Plan Review Stops For Permit 23021238
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2023-02-28 Cont ID  
Sent By cpuell Date 2023-02-28 Time 11:07 Rev Time 0.00
Received By cpuell Date 2023-02-28 Time 11:07 Sent To  
Notes
2023-02-28 11:08:18ADDRESS APPROPRIATE FOR PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2023-07-12 Cont ID  
Sent By cthroop Date 2023-07-12 Time 06:42 Rev Time 0.00
Received By cthroop Date 2023-07-12 Time 06:41 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-07-11 Cont ID  
Sent By cthroop Date 2023-07-11 Time 07:42 Rev Time 0.00
Received By cthroop Date 2023-07-11 Time 06:31 Sent To  
Notes
2023-07-11 07:44:08NOTICE: APPROVAL OF THE BUILDING REVIEW IS PENDING
 APPROVAL OF THE ELEVATION CERTIFICATE. SEE COMMENTS
 UNDER THE NFIP REVIEW. CT

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-05-16 Cont ID  
Sent By cthroop Date 2023-05-16 Time 16:10 Rev Time 0.00
Received By cthroop Date 2023-05-16 Time 15:04 Sent To  
Notes
2023-05-16 16:12:122ND BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: STRUCTURES ARE LOCATED SPECIAL FLOOD HAZARD
 AREA'S (SFHA). SEE COMMENTS UNDER NFIP REVIEW. FEMA
 ELEVATION CERTIFICATE REQUIRED.
  
 1.PROVIDE A COPY OF THE MOST RECENT BOUNDY LINE SURVEY.
 (2ND REQUEST. SURVEY SUBMITTED FOR REVIEW IS FOR 5210
 ESSEX CT)
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-24 Cont ID  
Sent By cthroop Date 2023-03-24 Time 10:42 Rev Time 0.00
Received By cthroop Date 2023-03-21 Time 08:14 Sent To  
Notes
2023-03-24 10:47:541ST BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: STRUCTURES ARE LOCATED SPECIAL FLOOD HAZARD
 AREA'S (SFHA). SEE COMMENTS UNDER NFIP REVIEW. FEMA
 ELEVATION CERTIFICATE REQUIRED.
  
 1.PROVIDE A COPY OF THE MOST RECENT BOUNDY LINE SURVEY.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. THE SOILS REPORT SUBMITTED FOR REVIEW IS FOR ADDRESS
 5210 ESSEX CT. SUBMIT A SOILS REPORT FOR 5300 ESSEX CT.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 3. PROVIDE A COPY OF THE CURRENT FLORIDA PRODUCT
 APPROVALS FOR THE PROPOSED WINDOWS AND EXT. DOORS.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 4.PROVIDE A WINDOW AND DOOR FLASHING DETAIL OR THE
 SPECIFICATION SHEETS OF A LIQUID APPLIED MEMBRANE.
 FBC R 703.4, FBC B 1405.4
  
 5. PROVIDE THE FINISHED FLOOR ELEVATION FOR EACH ROOM
 ON THE FLOOR PLANS.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 6. PROVIDE A ROOF TO WALL CONNECTOR SCHEDULE.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 7. PROVIDE A LINTEL SCHEDULE.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 8.PROVIDE A COPY OF THE CURRENT FLORIDA PRODUCT
 APPROVALS FOR THE PROPOSED LINTELS.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 9.PROVIDE LOCATION OF ATTIC ACCESS PER R807.1.7.
 R807.1.7 BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF
 CONSTRUCTION SHALL HAVE AN ATTIC ACCESS OPENING TO
 ATTIC AREAS THAT HAVE A VERTICAL HEIGHT OF 30 INCHES
 (762 MM) OR GREATER OVER AN AREA OF NOT LESS THAN 30
 SQUARE FEET (2.8 M2).
  
 10.PROVIDE THE DESIGN PRESSURES FOR NEW ROOFING PER
 FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES
 R301.2.1.1WIND DESIGN REQUIRED.
  
 11.PROVIDE A ROOF SHEATHING FASTENER SCHEDULE PER THE
 ENHANCED CALCULATED DESIGN PRESSURES OF ZONES 2 AND 3.
 TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING
 SCHEDULE FOR WOOD STRUCTURAL PANELS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2023-06-22 Cont ID  
Sent By rperdomo Date 2023-06-22 Time 15:10 Rev Time 0.00
Received By rperdomo Date 2023-06-22 Time 14:49 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-05-10 Cont ID  
Sent By rperdomo Date 2023-05-10 Time 12:55 Rev Time 0.00
Received By rperdomo Date 2023-05-10 Time 11:12 Sent To  
Notes
2023-05-10 12:55:14FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: APPROVED, SEE COMMENTS BELOW
  
 1. A SEPARATE PERMIT APPLICATION IS REQUIRED FOR EACH
 OF THE FOLLOWING ITEM:
 A. LOW VOLTAGE WIRING
 B. GENERATOR SYSTEM
 C. SWIMMING POOL
  
 END OF COMMENTS
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER/ INSPECTOR
 561-805-6738
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-03-15 Cont ID  
Sent By rperdomo Date 2023-03-15 Time 14:48 Rev Time 0.00
Received By rperdomo Date 2023-03-15 Time 13:13 Sent To  
Notes
2023-03-15 14:48:45FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. LOAD CALCULATION FOR SERVICE DOES NOT INCLUDE
 EXISTING EQUIPMENT AS LISTED ON THE MOTOR CIRCUIT
 SCHEDULE ON PAGE 133 E600-ELECTRICAL SCHEDULE (THE
 CALCULATION ONLY SHOWS 12 AHU).
 NEC 220
  
 2. SERVICE RECEPTACLE PER NEC 210.63 OR IRC E3901.11
 THE RECEPTACLE MUST BE IN A READILY ACCESSIBLE LOCATION
 FROM THE EQUIPMENT AND MUST BE GFCI-PROTECTED AS
 APPLICABLE TO OUTDOOR RECEPTACLES AT DWELLING
 OCCUPANCIES.
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2023-05-19 Cont ID  
Sent By parking Date 2023-05-19 Time 15:35 Rev Time 0.00
Received By lquinone Date 2023-05-19 Time 15:35 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2023-06-15 Cont ID  
Sent By ccole Date 2023-06-15 Time 14:50 Rev Time 0.00
Received By ccole Date 2023-06-15 Time 13:24 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2023-04-28 Cont ID  
Sent By ccole Date 2023-04-28 Time 11:00 Rev Time 0.00
Received By ccole Date 2023-04-28 Time 11:00 Sent To  
Notes
2023-04-28 11:01:002ND REVIEW FBC-2020 RES. GAS
 PERMIT- 23021238
 4/28/23
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P701 REVISED GAS RISER COMMENTS- SEC.
 107.3.5.3 FBC RES.
  
 A) BASED ON TABLE G2413.4(1) FBC RES THE 1-INCH STEEL
 PIPE SUPPLYING GWH 1 & 2 SHALL BE INCREASED TO
 1-1/4-INCH, AND THE 3/4-INCH LINE TO GWH-2 SHALL BE
 INCREASED TO 1-INCH.
  
 B) SHOW THE GAS PIPING BRANCH LINE TO THE DRYERS AND
 LOCATIONS OF REGULATORS.
  
 C) PLEASE SHOW A LOW-PRESSURE REGULATOR AT THE BBQ AND
 SIZE AND LENGTH OF THE SUPPLY PIPE.
  
 2) P101A & P701: SHOW THE LOCATION AND SIZE OF THE
 COMBUSTION AIR INTAKE LOUVER FOR THE GENERATOR- SEC.
 G2407.6.2. PLEASE NOTE IF USING THE ONE-OPENING METHOD
 THE MINIMUM NET OPENING SIZE OF THE LOUVER SHALL BE 625
 SQ. INCHES AND THE LOUVER SHALL COMMENCE WITHIN
 12-INCHES OF THE TOP OF THE ENCLOSURE.
  
 3) P101A & P701: 2ND REQUEST FOR GENERATOR EXHAUST
 VENTING PLAN- SEC. G2427.1.
  
 4) P101A, P102 & P701: 2ND REQUEST FOR COMBUSTION AIR
 AND VENTING PLANS FOR GWH-1 & 2. THE REVISED PLAN
 INDICATES A DIRECT, CONCENTRIC TYPE SYSTEM THROUGH THE
 ROOF. PLEASE PROVIDE A DIAGRAM SHOWING THE TYPE AND
 SIZE OF CONCENTRIC VENT, VENT RUN, AND TERMINATION
 LOCATIONS ON THE ROOF- SEC. G2427.2 & G2427.8 ITEM 3.
  
 5) P101A & P701: THE REVISED PLAN SHOWS COMBUSTION AIR
 FOR THE DRYERS WILL BE SUPPLIED MECHANICALLY. PLEASE
 REFER TO SEC. G2407.9 AND SHOW HOW THE AIR WILL BE
 PROVIDED MECHANICALLY AT A RATE OF 0.35 CFM PER 1000
 BTUH. PLEASE NOTE IF USING THE AC SYSTEM, THE SYSTEM
 SHALL PROVIDE THE SPECIFIED AIR RATE IN ADDITION TO THE
 REQUIRED VENTILATION AIR. ADVISORY- PLEASE REVIEW SEC.
 G2407.1 EXCEPTION FOR MAKEUP AIR USE PER G2439.5.
  
 6) P101A & P701: THE REVISED PLAN SHOWS COMBUSTION AIR
 FOR THE RANGE TO BE PROVIDED VIA A CONCENTRIC VENT AIR
 INTAKE VIA THE ROOF. PLEASE REFER TO G2407.11 AND
 PROVIDE DETAILS INCLUDING TYPE AND SIZE OF COMBUSTION
 AIR DUCT, DUCT RUN AND TERMINATION LOCATION. IF
 COMBINING INDOOR AND OUTDOOR AIR PLEASE SEE SECS.
 G2407.7- G2407.7.3 AND PROVIDE CALCULATIONS AND
 DETAILS.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-03-01 Cont ID  
Sent By ccole Date 2023-03-01 Time 14:55 Rev Time 0.00
Received By ccole Date 2023-02-28 Time 12:22 Sent To  
Notes
2023-03-01 14:56:221ST REVIEW FBC-2020 RES. GAS
 PERMIT- 23021238
 3/1/23
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P701 GAS RISER: BASED ON THE GAS INFO SHOWN ON
 THE PLAN PLEASE LABEL THE EXTERIOR UNDERGROUND PIPING
 AS PE AND THE INTERIOR AS SCHEDULE 40 METALLIC.
 CONCERNING THE SCHEDULE 40 UNDER THE HOUSE SLAB PLEASE
 REFER TO SECS. G2415.11- G2415.11.2 FBC RES AND PROVIDE
 CORROSION PROTECTION FOR THE PIPING. PLEASE NOTE ZINC
 COATING IS NOT DEEMED ADEQUATE PROTECTION.
  
 2) P101A, P701: PROVIDE COMBUSTION AND EXHAUST VENTING
 PLANS FOR THE GENERATOR- SECS. G2407.1 AND G2427.1 FBC
 FG. A SEPARATE PERMIT IS REQUIRED FOR THE GENERATOR THE
 HOWEVER DESIGN OF THE SYSTEMS SHOULD BE REVIEWED UNDER
 THE MAIN PERMIT SINCE THE GENERATOR IS LOCATED INSIDE
 THE HOUSE AND COULD IMPACT THE OVERALL DESIGN INCLUDING
 EXHAUST VENT CLEARANCES TO MECHANICAL AND GRAVITY AIR
 INTAKES INTO THE BUILDING- SEC. R303.5.1 FBC RES.
 PLEASE NOTE A DISTANCE OF 10 FT. IS REQUIRED.
 A) PLEASE PLACE A SEPARATE PERMIT NOTE FOR THE
 GENERATOR ON THE RISER DRAWING- SEC. 107.2.1 WPB.
  
 3) P101A, P102 & P701: PLEASE PROVIDE COMBUSTION AIR
 AND VENTING PLANS FOR THE GAS WATER HEATERS GWH-1 & 2-
 SECS. G2407.1, G2427.1, & G2448.1 FBC RES. PLEASE NOTE
 DIRECT VENT SYSTEMS SHALL COMPLY WITH G2427.2 & G2427.8
 ITEM 3- FBC RES.
  
 4) P100B: SHOW THE LOCATION OF GWH-3 AND THE PIPING RUN
 TO IT- SEC. 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-07-11 Cont ID  
Sent By cthroop Date 2023-07-11 Time 07:46 Rev Time 0.00
Received By cthroop Date 2023-06-12 Time 09:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-05-19 Cont ID  
Sent By aoliver Date 2023-05-19 Time 16:27 Rev Time 0.00
Received By aoliver Date 2023-04-26 Time 16:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-24 Cont ID  
Sent By cthroop Date 2023-03-24 Time 10:47 Rev Time 0.00
Received By cthroop Date 2023-02-27 Time 12:12 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2023-07-17 Cont ID  
Sent By lmarchan Date 2023-07-17 Time 15:21 Rev Time 0.00
Received By lmarchan Date 2023-07-12 Time 08:20 Sent To  
Notes
2023-07-17 15:21:31RECEIPT MU-2023-031182 - $12,378.21 PAID
2023-07-12 08:20:38EMAILED IMPACT FOR REVIEW-AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-03-22 Cont ID  
Sent By cthroop Date 2023-03-22 Time 16:04 Rev Time 0.00
Received By cthroop Date 2023-03-21 Time 08:14 Sent To  
Notes
2023-03-22 16:05:33IMPACT FEES
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2023-06-27 Cont ID  
Sent By cmontell Date 2023-06-27 Time 13:18 Rev Time 0.00
Received By cmontell Date 2023-06-27 Time 13:18 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2023-05-08 Cont ID  
Sent By medwards Date 2023-05-08 Time 07:21 Rev Time 0.00
Received By medwards Date 2023-05-08 Time 07:21 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-03-06 Cont ID  
Sent By medwards Date 2023-03-06 Time 07:33 Rev Time 0.00
Received By medwards Date 2023-03-02 Time 16:12 Sent To  
Notes
2023-03-06 07:33:371ST REVIEW FMC
 PERMIT: 23021238
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE ENERGY CALCULATIONS WILL NEED THE PREPARERS NAME
 AND SIGNED BY THE OWNER/AGENT.
  
 2) ADD A NOTE ON THE MECHANICAL DRAWINGS THAT THE
 GENERATOR WILL REQUIRE A SEPARATE PERMIT APPLICATION,
 DOCUMENT SUBMITTAL AND PLAN REVIEW AS THE GENERATOR
 WILL NOT BE REVIEWED UNDER THIS PERMIT.
  
 3) THE MECHANICAL CALCULATIONS ARE NOT CONSISTENT WITH
 THE MECHANICAL DRAWINGS SUBMITTED. THE EQUIPMENT SIZING
 CALCULATIONS SHOW 3 SYSTEMS. SHEET M600 HAS 18 AHU???S
 AND 12 HEAT PUMPS. SHEETS M101A AND M101B SHOW ONLY 10
 HEAT PUMPS.
  
 4) THE WATER CLOSET COMPARTMENT IN THE PRIMARY BATH ON
 THE 2ND FLOOR WILL NEED TO MEET THE EXHAUST REQUIREMENT
 OF FRC R303.3
  
 5) SHEET M101A: IDENTIFY THE ITEM THAT IS LEAVING THE
 GENERATOR TOWARDS THE L-1 HP-1.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 4 Status P Date 2023-07-12 Cont ID  
Sent By cthroop Date 2023-07-12 Time 06:42 Rev Time 0.00
Received By cthroop Date 2023-07-12 Time 06:42 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status F Date 2023-07-11 Cont ID  
Sent By cthroop Date 2023-07-11 Time 07:44 Rev Time 0.00
Received By cthroop Date 2023-07-11 Time 06:31 Sent To  
Notes
2023-07-11 07:46:023RD NFIP REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
 FEMA DESK REFERENCE P 758
 FBC R322 FLOOD-RESISTANT CONSTRUCTION
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD
 HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATIONS FOR
 THIS SITE ARE AE 6 AND AE 7 WITH A BASE FLOOD
 ELEVATIONS (BFE) OF 6'0" AND 7'0" NAVD.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD.
 THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE
 9'0" NAVD.
  
 NOTICE: SUBMIT A CORRECTED EC.
  
 1. LINES A8 B) & C) SHALL BE N/A PER EC INSTRUCTIONS.
  
 2. LINES A9 B) & C) SHALL BE N/A PER EC INSTRUCTIONS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2023-05-17 Cont ID  
Sent By cthroop Date 2023-05-17 Time 06:27 Rev Time 0.00
Received By cthroop Date 2023-05-16 Time 15:04 Sent To  
Notes
2023-05-16 16:55:08PEER REVIEW COMPLETED - RMCP
2023-05-16 16:17:372ND NFIP REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
 FEMA DESK REFERENCE P 758
 FBC R322 FLOOD-RESISTANT CONSTRUCTION
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: THIS PROJECT IS LOCATED IN A SPECIAL FLOOD
 HAZARD AREA (SFHA). THE FLOOD ZONE DESIGNATIONS FOR
 THIS SITE ARE AE 6 AND AE 7 WITH A BASE FLOOD
 ELEVATIONS (BFE) OF 6'0" AND 7'0" NAVD.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD.
 THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE
 9'0" NAVD.
  
 NOTICE: 1ST REVIEW OF THE CONSTRUCTION DRAWING EC.
  
 1. LINES A8 B) & C) SHALL BE N/A PER EC INSTRUCTIONS.
  
 2. LINES A9 B) & C) SHALL BE N/A PER EC INSTRUCTIONS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2023-03-22 Cont ID  
Sent By cthroop Date 2023-03-22 Time 16:06 Rev Time 0.00
Received By cthroop Date 2023-03-21 Time 12:35 Sent To  
Notes
2023-03-22 16:07:191ST NFIP REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
 FEMA DESK REFERENCE P 758
 FBC R322 FLOOD-RESISTANT CONSTRUCTION
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1.THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD
 AREA (SFHA). THE FLOOD ZONE DESIGNATIONS FOR THIS SITE
 ARE AE 6 AND AE 7 WITH A BASE FLOOD ELEVATIONS (BFE) OF
 6'0" AND 7'0" NAVD.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD.
 THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE
 9'0" NAVD.
  
 CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17
 SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT
 CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE
 II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL
 AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH
 SHALL READ AS FOLLOWS:
  
 SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE, RESIDENTIAL.
 R322.2.1 ELEVATION REQUIREMENTS.
 1.BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT
 DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST
 FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION
 PLUS ONE FOOT, OR THE DESIGN FLOOD ELEVATION, WHICHEVER
 IS HIGHER. (PLUS TWO FEET PER CITY ORDINANCE 4729-17).
  
 2. PROVIDE THE FOLLOWING (3) ELEVATION CERTIFICATES AS
 REQUIRED.
  
 A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS
 REQUIRED AT TIME OF PERMIT APPLICATION.
  
 A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AT PLACEMENT OF 1ST FLOOR.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-06-15 Cont ID  
Sent By ccole Date 2023-06-15 Time 14:49 Rev Time 0.00
Received By ccole Date 2023-06-15 Time 13:24 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-04-28 Cont ID  
Sent By ccole Date 2023-04-28 Time 11:01 Rev Time 0.00
Received By ccole Date 2023-04-28 Time 11:01 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-03-01 Cont ID  
Sent By ccole Date 2023-03-01 Time 14:09 Rev Time 0.00
Received By ccole Date 2023-02-28 Time 12:22 Sent To  
Notes
2023-03-01 14:10:511ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 23021238
 3/1/23
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS P100, P1008, & P700: PLEASE SHOW THE
 LOCATIONS OF REQUIRED CLEANOUTS AT THE JUNCTIONS OF THE
 BUILDING DRAINS AND SEWER LINE ON THE SOUTH SIDE- SEC.
 P3005.2.3 FBC RES.
  
 2) P700 SANITARY RISER: THERE IS A MISSING DRY VENT AT
 L1 FOR THE 1ST FLOOR POWDER ROOM 109 WET VENT SYSTEM-
 SEC. P3108.1 FBC RES
 3) P700 SANITARY RISER: WASHING MACHINE STANDPIPES AND
 TRAP VENTING NOT SHOWN- SECS. P2706.1.2.1 & P2718.1 FBC
 RES.
  
 4) P100B & P700: A) GYM BATH- PLEASE CHANGE (WC-1) TO
 (SH-2) ON THE RISER DRAWING- SEC. 107.2.1 WPB. B)
 PROVIDE A VENT FOR THE POOL HOUSE KITCHEN SINK (S-1)-
 SEC. P3106.1 FBC RES.
  
 5) C4.0: THE PLANS SHOW SEPARATE METERS AND SERVICES
 FOR POTABLE WATER AND IRRIGATION. EACH SYSTEM WILL
 REQUIRE INSTALLATION OF A BACKFLOW PREVENTER AND A
 SEPARATE PERMIT APPLICATION FOR EACH SHALL BE SUBMITTED
 PRIOR TO ISSUANCE OF THE MAIN HOUSE PERMIT- SEC. 105.1
 & 107.2.1 WPB. YOU CAN SUBMIT AN APPLICATION TBD (TO BE
 DETERMINED) IF YOU DO NOT HAVE A CONTRACTOR SELECTED BY
 EMAILING A COMPLETED PERMIT APPLICATION TO
 [email protected]. YOU WILL RECEIVE INSTRUCTIONS
 TO PAY FEES AND UPLOAD PLANS. YOU MAY UPLOAD PLANS AND
 PAY FEES AT A FUTURE DATE, BUT THE APPLICATION IS
 REQUIRED AT THIS TIME. WE RECOMMEND THAT YOU PAY FEES
 AND UPLOAD PLANS AT THE SAME TIME. AFTER YOU HAVE THE
 PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL AND I WILL
 CHANGE THE REVIEW STATUS TO PASS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2023-03-22 Cont ID  
Sent By dbattles Date 2023-03-22 Time 09:51 Rev Time 0.00
Received By dbattles Date 2023-03-22 Time 09:51 Sent To  
Notes
2023-03-22 09:52:00PRIVATE PROVIDER FOR INSPECTIONS
 DOCUMENTS SENT TO FILENET

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2023-03-22 Cont ID  
Sent By cthroop Date 2023-03-22 Time 16:43 Rev Time 0.00
Received By cthroop Date 2023-03-21 Time 08:14 Sent To  
Notes
2023-03-22 16:44:32PROVISO ON PLAN PAGE S106: A SEPERATE ROOFING PERMIT IS
 REQUIRED. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-07-11 Cont ID  
Sent By cthroop Date 2023-07-11 Time 07:42 Rev Time 0.00
Received By cthroop Date 2023-07-11 Time 06:31 Sent To  
Notes
2023-06-15 14:49:48PLUMBING/GAS PLAN SIGNATURES PASSED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-05-16 Cont ID  
Sent By cthroop Date 2023-05-16 Time 16:12 Rev Time 0.00
Received By cthroop Date 2023-05-16 Time 15:04 Sent To  
Notes
2023-04-28 11:02:07PLUMBING AND GAS PLANS PASSED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-03-24 Cont ID  
Sent By cthroop Date 2023-03-24 Time 09:32 Rev Time 0.00
Received By cthroop Date 2023-03-02 Time 07:40 Sent To  
Notes
2023-03-06 07:34:17MECHANICAL DIGITAL SIGNATURES APPROVED ME
2023-03-01 11:52:54INSTOP BY ACCIDENT. PLUMBING AND GAS (P) PLAN SIGS
 PASSED.

Review Stop Z ZONING
Rev No 4 Status P Date 2023-07-05 Cont ID  
Sent By vbroglia Date 2023-07-05 Time 09:29 Rev Time 0.00
Received By vbroglia Date 2023-07-05 Time 09:29 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2023-06-27 Cont ID  
Sent By vbroglia Date 2023-06-27 Time 10:45 Rev Time 0.00
Received By vbroglia Date 2023-06-27 Time 10:45 Sent To  
Notes
2023-06-27 10:46:23LANDSCAPE PERMIT IS REQUIRED TO MOVE PERMIT FORWARD

Review Stop Z ZONING
Rev No 2 Status P Date 2023-05-09 Cont ID  
Sent By vbroglia Date 2023-05-09 Time 14:46 Rev Time 0.00
Received By vbroglia Date 2023-05-09 Time 14:46 Sent To  
Notes
2023-05-09 14:49:35LANDSCAPE PERMIT REQUIRED

Review Stop Z ZONING
Rev No 1 Status F Date 2023-03-17 Cont ID  
Sent By AJVann Date 2023-03-17 Time 14:10 Rev Time 0.00
Received By ajones Date 2023-03-17 Time 14:10 Sent To  
Notes
2023-03-17 14:20:593/17/23- FAILED
 PLEASE ADDRESS THE FOLLOWING COMMENTS IN YOUR
 RESUBMITAL:
  
 1.SECTION 94-72 A.3. STATES THAT THE MAXIMUM BUILDING
 HEIGHT:30 FEET. PLEASE REVISED THE PLANS ACCORDINGLY
 2. DOES THE POOL HOUSE HAVE A FULL KITCHEN
 3. THE WALL ALONG FLAGLER DRIVE CAN GO TO A MAXIMUM
 HEIGHT OF 6 FEET
 4. SEPERATE PERMIT REQUIRED FOR LANDSCAING, SITE WALLS
 AND FENCES, DRIVEWAYS, SWIMMING POOLS AND OTHER
 HARDSCAPE.
  
 ANGELLA VANN, AICP
 561-822-1441
 [email protected]
  
  