Plan Review Details - Permit 23021237
Plan Review Stops For Permit 23021237
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2023-02-28 Cont ID  
Sent By cpuell Date 2023-02-28 Time 11:24 Rev Time 0.00
Received By cpuell Date 2023-02-28 Time 11:24 Sent To  
Notes
2023-02-28 11:24:58ADDRESS APPROPRIATE FOR PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-07-07 Cont ID  
Sent By cthroop Date 2023-07-07 Time 10:17 Rev Time 0.00
Received By cthroop Date 2023-07-07 Time 06:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-05-16 Cont ID  
Sent By cthroop Date 2023-05-16 Time 10:19 Rev Time 0.00
Received By cthroop Date 2023-05-16 Time 05:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-22 Cont ID  
Sent By cthroop Date 2023-03-22 Time 13:29 Rev Time 0.00
Received By cthroop Date 2023-03-21 Time 08:12 Sent To  
Notes
2023-03-22 13:31:021ST BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: STRUCTURES ARE LOCATED SPECIAL FLOOD HAZARD
 AREA'S (SFHA). SEE COMMENTS UNDER NFIP REVIEW. FEMA
 ELEVATION CERTIFICATE REQUIRED.
  
 1.PROVIDE A COPY OF THE MOST RECENT BOUNDY LINE SURVEY.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
  
 2. SITE PLAN SUBMITTED FOR REVIEW IS FOR 5300 ESSEX CT.
 PROVIDE A SITE PLAN W/BOUNDRY LINE SURVEY. IDENTIFY
 LOCATION OF WORK. REMOVE ANY REFERENCE TO EXISTING
 STRUCTURES.
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE
 SITE,... AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN
 ACCURATE AND INCLUDED BOUNDRY LINE SURVEY.
  
 3. REMOVED
  
 4. THE PRODUCT APPROVAL FOR THE OVERHEAD DOOR (OHD) HAS
 EXPIRED.
 PROVIDE A COPY OF THE CURRENT FLORIDA PRODUCT APPROVALS
 FOR THE PROPOSED OHD.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 5.PROVIDE A WINDOW AND DOOR FLASHING DETAIL OR THE
 SPECIFICATION SHEETS OF A LIQUID APPLIED MEMBRANE.
 FBC R 703.4, FBC B 1405.4
  
 6. PROVIDE THE ICC-ES REPORT FOR THE SPRAY FOAM
 INSULATION.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 7. PROVIDE THE FINISHED FLOOR ELEVATION FOR EACH ROOM
 ON THE FLOOR PLANS.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 8. PROVIDE THE STAIR HANDRAIL DETAIL FOR THE GARGAE
 STAIRS.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 9. PROVIDE A ROOF TO WALL CONNECTOR SCHEDULE.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 10. PROVIDE A LINTEL SCHEDULE.
 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE
 WITH SECTIONS107.2.1 THROUGH 107.2.5.
  
 11.PROVIDE A COPY OF THE CURRENT FLORIDA PRODUCT
 APPROVALS FOR THE PROPOSED LINTELS.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 12.PROVIDE LOCATION OF ATTIC ACCESS PER R807.1.7.
 R807.1.7 BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF
 CONSTRUCTION SHALL HAVE AN ATTIC ACCESS OPENING TO
 ATTIC AREAS THAT HAVE A VERTICAL HEIGHT OF 30 INCHES
 (762 MM) OR GREATER OVER AN AREA OF NOT LESS THAN 30
 SQUARE FEET (2.8 M2).
  
 13.PROVIDE THE DESIGN PRESSURES FOR NEW ROOFING PER
 FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES
 R301.2.1.1WIND DESIGN REQUIRED.
  
 14.PROVIDE A ROOF SHEATHING FASTENER SCHEDULE PER THE
 ENHANCED CALCULATED DESIGN PRESSURES OF ZONES 2 AND 3.
 TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING
 SCHEDULE FOR WOOD STRUCTURAL PANELS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-05-02 Cont ID  
Sent By rperdomo Date 2023-05-02 Time 14:37 Rev Time 0.00
Received By rperdomo Date 2023-05-02 Time 14:06 Sent To  
Notes
2023-05-02 14:39:28FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: APPROVED, SEE COMMENTS BELOW
  
 1. GENERATOR AND SWIMMING POOL, EACH REQUIRES A
 SEPARATE PERMIT APPLICATION.
  
 END OF COMMENTS
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER/ INSPECTOR
 561-805-6738
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-03-15 Cont ID  
Sent By rperdomo Date 2023-03-15 Time 13:06 Rev Time 0.00
Received By rperdomo Date 2023-03-15 Time 09:40 Sent To  
Notes
2023-03-15 11:30:00FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. PROVIDE LOAD CALCULATION FOR SERVICE IN ACCORDANCE
 WITH NE 220.
  
 2. PROVIDE AN ONE-LINE DIAGRAM SHOWING INFORMATION OF
 SERVICE EQUIPMENT (SERVICE CONDUCTORS, SERVICE
 OVERCURRENT PROTECTION, GROUNDED CONDUCTOR, EQUIPMENT
 GROUNDING CONDUCTORS (EGC), MAIN PANEL AND SUBPANELS).
 NEC 230, 250
  
 3. SERVICE RECEPTACLE PER NEC 210.63 OR IRC E3901.11
 THE RECEPTACLE MUST BE IN A READILY ACCESSIBLE LOCATION
 FROM THE EQUIPMENT AND MUST BE GFCI-PROTECTED AS
 APPLICABLE TO OUTDOOR RECEPTACLES AT DWELLING
 OCCUPANCIES
  
 4. AT LEAST ONE 120-VOLT, 20-AMPERE BRANCH CIRCUIT
 SHALL BE INSTALLED TO SUPPLY RECEPTACLE OUTLETS IN
 ATTACHED GARAGES AND IN DETACHED GARAGES WITH ELECTRIC
 POWER. THIS CIRCUIT SHALL HAVE NO OTHER OUTLETS AS PER
 NEC 210.11(C)(4)
  
 5. SWIMMING POOL REQUIRES A SEPARATE PERMI NUMBER.
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2023-05-19 Cont ID  
Sent By parking Date 2023-05-19 Time 15:34 Rev Time 0.00
Received By lquinone Date 2023-05-19 Time 15:34 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2023-06-20 Cont ID  
Sent By rwbrown Date 2023-06-08 Time 10:03 Rev Time 0.00
Received By rwbrown Date 2023-06-08 Time 10:03 Sent To  
Notes
2023-06-08 10:06:443RD GAS REVIEW - AMENDED 6-20-23 CHANGED COMMENT #1 TO
 DONE
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. DONE
  
 2. DONE
  
 3. DONE
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2023-04-24 Cont ID  
Sent By rwbrown Date 2023-04-24 Time 12:20 Rev Time 0.00
Received By rwbrown Date 2023-04-24 Time 12:20 Sent To  
Notes
2023-04-24 12:22:522ND GAS REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMENDS 107.3.5.1.5 - A DETAIL FOR THE WATER
 HEATER VENTING IS NOT SHOWN.
  
 2. 2017 WPB AMENDS 107.3.5.1.5 - A DETAIL FOR THE DRYER
 MAKEUP AIR IS NOT SHOWN
  
 3. 2017 WPB AMENDS 107.3.5.1.5 - DETAIL FOR THE
 FIREPLACE VENTING NOT SHOWN.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2023-02-28 Cont ID  
Sent By rwbrown Date 2023-02-28 Time 14:03 Rev Time 0.00
Received By rwbrown Date 2023-02-28 Time 10:18 Sent To  
Notes
2023-03-15 11:27:46 
  
2023-02-28 14:18:361ST GAS REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMEND 107.3.5.3 (13) - PLEASE SUBMIT A GAS
 RISER DIAGRAM THAT INCLUDES ANY OF THE FOLLOWING
 APPLICABLE ITEMS.
 A) AN ISOMETRIC THAT INCLUDES - PIPE MATERIAL, LOCATION
 OF SHUT OFFS, PIPING LENGTHS, PIPE PRESSURES, LOCATION
 OF REGULATORS, BTU LOADS FROM EACH APPLIANCE,
 INDIVIDUAL SYSTEM SIZING WITH REFERENCES TO SIZING
 TABLES FROM THE CODE.
 B) A FLOOR PLAN THAT INCLUDES APPLIANCE LOCATIONS AND
 COMBUSTION AIR/MAKE UP AIR SIZING FOR EACH APPLIANCE
 WITHIN THE ROOM THAT CONTAINS IT.
 C) VENTING DETAILS FOR APPLIANCES THAT VENT TO THE
 OUTDOORS, INCLUDE DISTANCES FOR SEPARATION FROM THE
 VENT TERMINATIONS TO OPERABLE WINDOWS, AIR INTAKES,
 ETC.
 D) CHIMNEY DETAILS FOR THE FIREPLACES
 E) SPECS FOR THE APPLIANCES
 F) SPECIAL ATTENTION TO THE GENERATOR ROOM AND THE
 COMBUSTION AIR INTAKES, EXHUASTS, SEPARATION EXHAUST
 AND INTAKES WITH OTHER SYSTEMS.
 I) SPECIAL NOTE FOR THE GENERATOR EXHAUST - 2020 FRC
 R303.5.1 - RESIDENTIAL GAS GENERATOR EXHAUST
 TERMINATION MUST BE 10 FEET FROM ANY OPENING INTO THE
 STRUCTURE AND FROM ANY LOT LINE/POSSIBLE OPENING INTO
 ANY OTHER STRUCTURE.
 G) DETAILS FOR ANY SLEEVING REQUIRED FOR PENETRATIONS
 INTO THE STRUCTURE OR UNDER THE STRUCTURE.
  
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-07-07 Cont ID  
Sent By cthroop Date 2023-07-07 Time 10:17 Rev Time 0.00
Received By cthroop Date 2023-06-07 Time 09:28 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-05-19 Cont ID  
Sent By aoliver Date 2023-05-19 Time 16:26 Rev Time 0.00
Received By aoliver Date 2023-04-21 Time 16:16 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-22 Cont ID  
Sent By cthroop Date 2023-03-22 Time 14:10 Rev Time 0.00
Received By cthroop Date 2023-02-27 Time 12:09 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2023-07-20 Cont ID  
Sent By lmarchan Date 2023-07-20 Time 09:42 Rev Time 0.00
Received By lmarchan Date 2023-07-10 Time 08:55 Sent To  
Notes
2023-07-19 13:39:25RECEIPT MU-2023-031269 - $12,378.21 PAID
2023-07-10 08:55:34EMAILED IMPACT FOR REVIEW-AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-03-22 Cont ID  
Sent By cthroop Date 2023-03-22 Time 07:28 Rev Time 0.00
Received By cthroop Date 2023-03-21 Time 08:12 Sent To  
Notes
2023-03-22 07:29:13IMPACT FEES
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2023-06-22 Cont ID  
Sent By cmontell Date 2023-06-22 Time 14:55 Rev Time 0.00
Received By cmontell Date 2023-06-22 Time 14:55 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2023-05-02 Cont ID  
Sent By medwards Date 2023-05-02 Time 11:14 Rev Time 0.00
Received By medwards Date 2023-05-02 Time 11:14 Sent To  
Notes
2023-05-02 11:14:322ND REVIEW FMC
 PERMIT: 23021237
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE MECHANICAL EQUIPMENT SIZING CALCULATIONS WERE
 NOT SUBMITTED IN THIS REVIEW CYCLE. PROVIDE THE
 CORRECTED MECHANICAL EQUIPMENT SIZING CALCULATIONS.
  
 2) PROVIDE THE CALCULATIONS FOR THE INTAKE LOUVERS
 SIZING AND THE EXHAUST FOR THE GENERATOR ROOM.
 FBC107.3.5
  
 3) THE ENGINEER OF RECORD WILL NEED TO DIGITALLY SIGN
 THE SUBMITTED MECHANICAL DRAWINGS. FS 471/481
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-02-28 Cont ID  
Sent By medwards Date 2023-02-28 Time 11:27 Rev Time 0.00
Received By medwards Date 2023-02-28 Time 11:27 Sent To  
Notes
2023-02-28 11:27:221ST REVIEW FMC
 PERMIT: 23021237
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE SUBMITTED MECHANICAL EQUIPMENT SIZING
 CALCULATIONS DESIGNED FOR 4 SYSTEMS, EACH BEING A
 NATURAL GAS FURNACE, DOES NOT MATCH THE MECHANICAL
 DRAWINGS THAT ARE DESIGNED WITH 22 AHU???S AND 12
 HP???S. THE MECHANICAL SIZING CALCULATIONS FBC 107.3.5
  
 2) SHEET M201-A: THE DRYERS APPEAR TO SHARE ONE SINGLE
 DRYER DUCT. PROVIDE A DETAIL OF THIS DESIGN SHOWING THE
 DUCT SIZES FOR THE SINGLE DRYERS AND ALSO THE DUCT
 AFTER THE 2 ARE JOINED. FRC M1502
  
 3) SHEET M201B: PROVIDE THE VENTILATION DETAILS FOR THE
 GENERATOR ROOM. WHERE IS THE INTAKE FOR THIS GENERATOR?
 FBC 107.3.5
  
 4) SHEET M202: EXPLAIN THE DAMPERS IN THE EXHAUST DUCT
 SYSTEM. FBC 107.3.5
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 3 Status P Date 2023-07-07 Cont ID  
Sent By cthroop Date 2023-07-07 Time 10:17 Rev Time 0.00
Received By cthroop Date 2023-07-07 Time 06:48 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 2 Status F Date 2023-05-16 Cont ID  
Sent By cthroop Date 2023-05-16 Time 14:30 Rev Time 0.00
Received By cthroop Date 2023-05-16 Time 05:38 Sent To  
Notes
2023-05-16 16:23:49PEER REVIEW COMPLETED RMCP
2023-05-16 14:36:402ND NFIP REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
 FEMA DESK REFERENCE P 758
 FBC R322 FLOOD-RESISTANT CONSTRUCTION
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1.THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD
 AREA (SFHA). THE FLOOD ZONE DESIGNATIONS FOR THIS SITE
 ARE AE 6 AND AE 7 WITH A BASE FLOOD ELEVATIONS (BFE) OF
 6'0" AND 7'0" NAVD.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD.
 THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE
 9'0" NAVD.
  
 NOTICE: 1ST REVIEW OF THE CONSTRUCTION DRAWING EC:
  
 1. LINES A8B) & C) SHALL BE N/A. (PER EC INSTRUCTIONS)
  
 2. LINES 9AB) & C) SHALL BE N/A. (PER EC INSTRUCTIONS)
  
 3. LINE C2E) STATES MACHINERY SERVICING BUILDING
 (GENERATOR PER COMMENTS) WILL BE AT 10.5'. PLAN PAGE
 A201B SHOWS MECH. ROOM (GENERATOR) IS AT 10.0'. PLEASE
 CLARIFY?
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  
  
  
  
2023-05-16 10:20:16PEER REVIEW REQUESTED 5/16/23. CT

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status F Date 2023-03-22 Cont ID  
Sent By cthroop Date 2023-03-22 Time 12:12 Rev Time 0.00
Received By cthroop Date 2023-03-21 Time 12:35 Sent To  
Notes
2023-03-22 12:14:011ST NFIP REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16 AND NO. 4729-17
 FEMA DESK REFERENCE P 758
 FBC R322 FLOOD-RESISTANT CONSTRUCTION
  
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1.THIS PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD
 AREA (SFHA). THE FLOOD ZONE DESIGNATIONS FOR THIS SITE
 ARE AE 6 AND AE 7 WITH A BASE FLOOD ELEVATIONS (BFE) OF
 6'0" AND 7'0" NAVD.
 THE CITY OF WEST PALM BEACH (THROUGH ORDINANCE NO.
 4729-17) REQUIRES AN ADDITIONAL 24 INCHES OF FREEBOARD.
 THE DESIGN FLOOD ELEVATION (DFE) SHALL BE AT OR ABOVE
 9'0" NAVD.
  
 CITY OF WEST PALM BEACH, FLORIDA ORDINANCE NO. 4729-17
 SECTION 4: THE CODE OF ORDINANCES IS HEREBY AMENDED AT
 CHAPTER 18, BUILDINGS AND BUILDING REGULATIONS, ARTICLE
 II, BUILDING CODE, TO ADD SECTION 18-33, TECHNICAL
 AMENDMENTS TO FLORIDA BUILDING CODE, RESIDENTIAL, WHICH
 SHALL READ AS FOLLOWS:
  
 SEC. 18-33 - TECHNICAL AMENDMENTS TO FLORIDA BUILDING
 CODE, RESIDENTIAL.
 R322.2.1 ELEVATION REQUIREMENTS.
 1.
 1.BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS NOT
 DESIGNATED AS COASTAL A ZONES SHALL HAVE THE LOWEST
 FLOORS ELEVATED TO OR ABOVE THE BASE FLOOD ELEVATION
 PLUS ONE FOOT, OR THE DESIGN FLOOD ELEVATION, WHICHEVER
 IS HIGHER. (PLUS TWO FEET PER CITY ORDINANCE 4729-17).
  
 2. PROVIDE THE FOLLOWING (3) ELEVATION CERTIFICATES AS
 REQUIRED.
  
 A CONSTRUCTION DRAWING ELEVATION CERTIFICATE IS
 REQUIRED AT TIME OF PERMIT APPLICATION.
  
 A BUILDING UNDER CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AT PLACEMENT OF 1ST FLOOR.
  
 A FINISHED CONSTRUCTION ELEVATION CERTIFICATE IS
 REQUIRED AND SHALL BE SUBMITTED FOR REVIEW AND APPROVAL
 PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2023-06-08 Cont ID  
Sent By rwbrown Date 2023-06-08 Time 10:10 Rev Time 0.00
Received By rwbrown Date 2023-06-08 Time 10:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-04-24 Cont ID  
Sent By rwbrown Date 2023-04-24 Time 09:41 Rev Time 0.00
Received By rwbrown Date 2023-04-24 Time 09:41 Sent To  
Notes
2023-04-24 11:19:532ND PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
  
 1. IF THERE ARE TWO METERS, ONE FOR IRRIGATION AND ONE
 FOR DOMESTIC WATER, EACH WILL NEED ITS OWN BACKFLOW AND
 ASSOCIATED PERMIT. ONLY ONE BACKFLOW PERMIT HAS BEEN
 APPLIED FOR.
  
 2017 WPB AMEND - 105.1/107.3 -- PAGE C4.0 INDICATES TWO
 SEPARATE METER CONNECTIONS. ONE FOR IRRIGATION AND ONE
 FOR THE POTABLE WATER. EACH WILL REQUIRE ITS OWN
 BACKFLOW PERMIT. THESE ARE REQUIRED TO BE APPLIED FOR
 PRIOR TO ISSUANCE OF THE PRIMARY PERMIT. YOU CAN SUBMIT
 AN APPLICATION "TBD" (TO BE DETERMINED) IF YOU DO NOT
 HAVE A CONTRACTOR SELECTED BY EMAILING A COMPLETED
 PERMIT APPLICATION TO [email protected]. AFTER
 YOU HAVE THE PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL
 OR NOTE IN THE RESPONSE LETTER AND I WILL COMPLY THIS
 COMMENT.
  
 2. NOT ADDRESSED --
  
 2017 WPB AMEND - 105.1/107.3 -- IRRIGATION WILL REQUIRE
 A SEPARATE PERMIT
  
 3. DONE - RISER SHOWN - SEE BELOW FOR INDIVIDUAL
 COMMENTS NOT ADDRESSED --
  
 A) DONE
  
 B) DONE
  
 C) DONE
  
 D) DONE
  
 E) DONE
  
 F) PAGE 201A PRIMARY BATH - 2017 WPB AMEND 107.3.5.3
 (12) - THE FLOOR PLAN SHOWS A 2" SAN UP TO SECOND FLOOR
 WHICH GOES TO THE WATER CLOSET. THE ISOMETRIC SHOWS A
 3". FIX THE FLOOR PLAN TO SHOW THE REQUIRED 3" TO THE
 WATER CLOSET.
  
 G) WYE IS STILL FACING BACKWARDS --
 PAGE 201A PRIMARY BATH - 2017 WPB AMEND 107.3.5.3 (12)
 - IN THE SAME AREA IT APPEARS ONE OF THE WYES IS FACING
 BACKWARDS.
  
 H) PAGE 201A PRIMARY BATH - THE BATHTUB IS MISSING FROM
 THE ISOMETRIC AND THE FLOOR PLAN.
  
 I) NEW COMMENT - THE ISOMETRIC DOES NOT MATCH THE FLOOR
 PLAN. THE TWO BATHROOMS NEAREST THE IT ROOM ARE NOT
 SHOWN THE SAME ON THE FLOOR PLAN AS THEY ARE ON THE
 ISOMETRIC. THE SHOWER AND WATER CLOSETS IN BOTH
 BATHROOMS ARE SWITCHED AROUND.
  
 4. IT IS TYPICAL AND MOST HELPFUL IF YOU SHOW A SECOND
 FLOOR PLUMBING PLAN WITH THE SANITARY TO THE SECOND
 FLOOR PLUMBING FIXTURES IMPOSED UNDER THE 2ND FLOOR UP
 TO THE CORRESPONDING 2ND FLOOR FIXTURES, MUCH LIKE THE
 1ST FLOOR IS SHOWN.
 2017 WPB AMEND 107.3.5.3 (12) - THE SECOND-FLOOR
 PLUMBING PLAN APPEARS TO BE MISSING.
  
 5. DONE
  
 6. 2017 WPB AMENDS 107.2.1 - THE REFERENCED PAGES IN
 THE KEY NOTES WITHIN THE PLAN ARE MISSING - A727, A718,
 A731, A734, ETC..?
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-02-28 Cont ID  
Sent By rwbrown Date 2023-02-28 Time 14:03 Rev Time 0.00
Received By rwbrown Date 2023-02-28 Time 10:18 Sent To  
Notes
2023-02-28 14:03:141ST PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 NOTE: PAGE SP100-SITE PLAN - THIS LAYOUT DOES NOT MATCH
 THE REST OF THE PAGES.
  
 1. 2017 WPB AMEND - 105.1/107.3 -- PAGE C4.0 INDICATES
 TWO SEPARATE METER CONNECTIONS. ONE FOR IRRIGATION AND
 ONE FOR THE POTABLE WATER. EACH WILL REQUIRED ITS OWN
 BACKFLOW PERMIT. THESE ARE REQUIRED TO BE APPLIED FOR
 PRIOR TO ISSUANCE OF THE PRIMARY PERMIT. YOU CAN SUBMIT
 AN APPLICATION "TBD" (TO BE DETERMINED) IF YOU DO NOT
 HAVE A CONTRACTOR SELECTED BY EMAILING A COMPLETED
 PERMIT APPLICATION TO [email protected]. AFTER
 YOU HAVE THE PERMIT(S) GENERATED, NOTIFY ME VIA EMAIL
 OR NOTE IN THE RESPONSE LETTER AND I WILL COMPLY THIS
 COMMENT.
  
 2. 2017 WPB AMEND - 105.1/107.3 -- IRRIGATION WILL
 REQUIRE A SEPARATE PERMIT
  
 3. 2017 WPB AMEND 107.3.5.3 (12) - PLEASE ADD A RISER
 IN ISOMETRIC FORM FOR PLUMBING REVIEW. A RISER IS
 ALWAYS REQUIRED. A PRELIMINARY REVIEW OF THE SANITARY
 FOLLOWS BUT WILL NEED TO HAVE THE ISOMETRIC FOR FULL
 REVIEW:
 A) PAGE P200B - POOL BATH AREA - 2020 FRC P3108.1 - THE
 KITCHENETTE CANNOT CONNECT INTO THE SHOWER FIXTURE
 DRAIN. IF A WET VENT SYSTEM IS BEING USED IN THE
 BATHROOM AREA, ANY OTHER FIXTURES WOULD NEED TO
 DISCHARGE DOWNSTREAM OF THE BATHROOM GROUP.
 B) PAGE P200B - POOL BATH AREA - 2020 FRC P3108.2.1 -
 IT APPEARS, BUT IS UNCLEAR THAT THE WATER CLOSET AND
 SHOWER ARE BOTH UPSTREAM OF THE VENTED FIXTURE'S
 (LAVATORY) CONNECTION. ONLY ONE FIXTURE WOULD BE
 ALLOWED UPSTREAM OF THE VENTED FIXTURE THAT CREATES THE
 WET VENT FOR THAT BATHROOM GROUP.
 C) PAGE P200B - POOL BATH AREA - 2020 FPC P3104.4 - THE
 PRIVATE WATER CLOSET HAS A DRYVENT THAT IS HORIZONTAL
 BELOW THE FLOOD RIM OF THE FIXTURE. A VENT SHALL RISE
 VERTICALLY TO 6" ABOVE THE FLOOD RIM OF THE FIXURE(S)
 SERVED.
 D) PAGE P200A - STAFF LOUNGE AREA - THE WATER CLOSET IS
 NOT VENTED TO CODE.
 E) PAGE P200A - KITCHEN AREA - 2020 FRC P3101.2.1 - IT
 IS UNCLEAR IF THE KITCHEN TRAPS ARE VENTED/STUDOR
 VENTED?
 THIS IS ALL I CAN SEE FOR NOW. PLEASE SUBMIT THE SECOND
 FLOOR PLAN AS WELL AS THE COMPLETE ISOMETRIC FOR THE
 SANITARY FOR REVIEW. INCLUDE THE CONTINUATION OF THE
 VENTING IN THE SANITARY ISOMETRIC
 F) PAGE 201A - 2017 WPB AMEND 107.3.5.3 (12) - IT
 APPEARS THE UPSTAIRS WATER CLOSET AND BATHTUB ARE
 MISSING FROM THE DRAWING.
 G)PAGE 201A - 2017 WPB AMEND 107.3.5.3 (12) - IN THE
 SAME AREA IT APPEARS ONE OF THE WYES IS FACING
 BACKWARDS.
  
 4. 2017 WPB AMEND 107.3.5.3 (12) - THE SECOND FLOOR
 PLUMBING PLAN APPEARS TO BE MISSING.
  
 5. PAGE 701 - 2017 WPB AMEND 107.3.5.3 (12) - THERE IS
 A NOTE ON THE WATER RISR-EAST THAT STATES "REFER TO
 P702" AND THERE IS NO PAGE 702.
  
  
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status P Date 2023-03-22 Cont ID  
Sent By dbattles Date 2023-03-22 Time 16:50 Rev Time 0.00
Received By dbattles Date 2023-03-22 Time 16:50 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2023-02-28 Time   Rev Time 0.00
Received By   Date 2023-02-28 Time   Sent To  
Notes
2023-02-28 07:55:18FS553.791, APPLICATION INDICATES THAT THIS PROJECT WILL
 UTILIZE A PRIVATE PROVIDER FOR INSPECTIONS. UPLOAD
 NOTICE TO BUILDING OFFICIAL, LICENSES, RESUMES,
 CERTIFICATE OF INSURANCE.
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2023-03-22 Cont ID  
Sent By cthroop Date 2023-03-22 Time 12:11 Rev Time 0.00
Received By cthroop Date 2023-03-21 Time 08:12 Sent To  
Notes
2023-03-22 12:12:09PROVISO ON PLAN PAGE A203A: A SEPERATE ROOFING PERMIT
 IS REQUIRED. CT

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-07-07 Cont ID  
Sent By cthroop Date 2023-07-07 Time 10:17 Rev Time 0.00
Received By cthroop Date 2023-07-07 Time 06:48 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-05-16 Cont ID  
Sent By cthroop Date 2023-05-16 Time 10:19 Rev Time 0.00
Received By cthroop Date 2023-05-16 Time 05:39 Sent To  
Notes
2023-05-02 11:15:51THE EOR FOR THE MECHANICAL DRAWINGS SUBMITTED THIS
 CYCLE WILL NEED TO DIGITALLY SIGN EACH DRAWING. ME

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-02-28 Cont ID  
Sent By rwbrown Date 2023-02-28 Time 14:31 Rev Time 0.00
Received By rwbrown Date 2023-02-28 Time 14:31 Sent To  
Notes
2023-02-28 11:27:54MECHANICAL DIGITAL SIGNATURES APPROVED ME

Review Stop Z ZONING
Rev No 4 Status P Date 2023-07-05 Cont ID  
Sent By vbroglia Date 2023-07-05 Time 09:26 Rev Time 0.00
Received By vbroglia Date 2023-07-05 Time 09:26 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2023-06-27 Cont ID  
Sent By vbroglia Date 2023-06-27 Time 10:28 Rev Time 0.00
Received By vbroglia Date 2023-06-27 Time 10:28 Sent To  
Notes
2023-06-27 10:30:00LANDSCAPE PERMIT STILL REQUIRED TO MOVE THIS PERMIT
 FORWARD

Review Stop Z ZONING
Rev No 2 Status F Date 2023-05-09 Cont ID  
Sent By vbroglia Date 2023-05-09 Time 13:15 Rev Time 0.00
Received By vbroglia Date 2023-05-09 Time 13:15 Sent To  
Notes
2023-05-09 13:30:49FAILED FOR THE FOLLOWING REASONS:
  
  
 1. LANDSCAPE PERMIT IS REQUIRED, YOU WILL NEED TO APPLY
 FOR A PERMIT TO MOVE THE BUILDING PERMIT FORWARD
  
 2. SEPERATE PERMIT IS REQUIRED FOR POOLS, FENCE/WALLS,
 DRIVEWAY, AND MECHANICAL EQUIPMENT.
  
 **** REVIEWD BY ****
 VALENTINA BROGLIA
 PLANNER
 [email protected]
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2023-03-17 Cont ID  
Sent By AJVann Date 2023-03-17 Time 14:22 Rev Time 0.00
Received By ajones Date 2023-03-17 Time 14:22 Sent To  
Notes
2023-03-17 14:23:073/17/23- FAILED
 PLEASE ADDRESS THE FOLLOWING COMMENTS IN YOUR
 RESUBMITAL:
  
 1.SECTION 94-72 A.3. STATES THAT THE MAXIMUM BUILDING
 HEIGHT:30 FEET. PLEASE REVISED THE PLANS ACCORDINGLY
 2. DOES THE POOL HOUSE HAVE A FULL KITCHEN
 3. THE WALL ALONG FLAGLER DRIVE CAN GO TO A MAXIMUM
 HEIGHT OF 6 FEET
 4. SEPERATE PERMIT REQUIRED FOR LANDSCAING, SITE WALLS
 AND FENCES, DRIVEWAYS, SWIMMING POOLS AND OTHER
 HARDSCAPE.
  
 ANGELLA VANN, AICP
 561-822-1441
 [email protected]
  