Plan Review Details - Permit 23021157
Plan Review Stops For Permit 23021157
Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2023-04-18 Cont ID  
Sent By pleduc Date 2023-04-18 Time   Rev Time 0.00
Received By pleduc Date 2023-04-18 Time 11:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-04-04 Cont ID  
Sent By pleduc Date 2023-04-04 Time   Rev Time 0.00
Received By pleduc Date 2023-04-04 Time 15:56 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-03-01 Cont ID  
Sent By pleduc Date 2023-03-01 Time   Rev Time 0.00
Received By pleduc Date 2023-02-28 Time 16:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-04-19 Cont ID  
Sent By medwards Date 2023-04-19 Time 10:25 Rev Time 0.00
Received By medwards Date 2023-04-19 Time 10:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-04-12 Cont ID  
Sent By medwards Date 2023-04-12 Time 11:28 Rev Time 0.00
Received By medwards Date 2023-04-03 Time 10:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-24 Cont ID  
Sent By medwards Date 2023-03-24 Time 09:43 Rev Time 0.00
Received By medwards Date 2023-03-20 Time 08:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-08 Cont ID  
Sent By medwards Date 2023-03-08 Time 09:04 Rev Time 0.00
Received By medwards Date 2023-02-27 Time 11:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2023-04-19 Cont ID  
Sent By medwards Date 2023-04-19 Time 10:23 Rev Time 0.00
Received By medwards Date 2023-04-19 Time 10:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2023-04-12 Cont ID  
Sent By medwards Date 2023-04-12 Time 10:47 Rev Time 0.00
Received By medwards Date 2023-04-12 Time 10:47 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2023-03-24 Cont ID  
Sent By medwards Date 2023-03-24 Time 09:42 Rev Time 0.00
Received By medwards Date 2023-03-24 Time 09:42 Sent To  
Notes
2023-03-24 09:43:272ND REVIEW FMC
 PERMIT: 23021157
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE THE KEY PLAN ASKED FOR IN PREVIOUS REVIEW
 CYCLE. THERE IS AN OCCUPANCY CLASSIFICATION FOR EVERY
 BUILDING. PROVIDE A UL DETAIL FOR THE PENETRATION
 PROTECTION OF THIS WALL. FBC 107.3.5
  
 2) THE TERMINATION FOR THIS SMOKER GREASE DUCT SHALL
 MEET ALL THE REQUIREMENTS OF FMC 506.3.13.3 FOR
 CLEARANCES FROM THE BUILDING. PROVIDE A ROOF DRAWING
 THAT CLEARLY SHOWS THE TERMINATION MEETS THE FOLLOWING
 CODE SECTION:
  
 506.3.13.3 TERMINATION LOCATION. EXHAUST OUTLETS SHALL
 BE LOCATED NOT LESS THAN 10 FEET (3048 MM) HORIZONTALLY
 FROM PARTS OF THE SAME OR CONTIGUOUS BUILDINGS,
 ADJACENT
 BUILDINGS AND ADJACENT PROPERTY LINES AND SHALL BE
 LOCATED NOT LESS THAN 10 FEET (3048 MM) ABOVE THE
 ADJOINING GRADE LEVEL. EXHAUST OUTLETS SHALL BE LOCATED
 NOT LESS THAN 10 FEET (3048 MM) HORIZONTALLY FROM OR
 NOT LESS THAN 3 FEET (914 MM) ABOVE AIR INTAKE OPENINGS
 INTO ANY BUILDING.
  
 EXCEPTION: EXHAUST OUTLETS SHALL TERMINATE NOT LESS
 THAN 5 FEET (1524 MM) HORIZONTALLY FROM PARTS OF THE
 SAME OR CONTIGUOUS BUILDING, AN ADJACENT BUILDING,
 ADJACENT PROPERTY LINE AND AIR INTAKE OPENINGS INTO A
 BUILDING WHERE AIR FROM THE EXHAUST OUTLET DISCHARGES
 AWAY FROM SUCH LOCATIONS.
  
 3) THE H-2 SHEET WILL NEED THE EOR TO DIGITALLY SIGN
 THE DRAWING. FS 471/481
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-03-08 Cont ID  
Sent By medwards Date 2023-03-08 Time 09:01 Rev Time 0.00
Received By medwards Date 2023-03-08 Time 09:01 Sent To  
Notes
2023-03-08 09:02:061ST REVIEW FMC
 PERMIT: 23021157
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE A KEY PLAN SHOWING WHAT IS BEHIND THE WALL
 THAT THIS NEW 12 INCH UL 103 HT DUCT IS PENETRATING.
 WHAT IS THE OCCUPANCY CLASSIFICATION OF THIS SPACE? IS
 THIS WALL A RATED WALL? IF THIS WALL IS RATED PROVIDE
 THE RATING. IF THIS WALL IS RATED PROVIDE A DESIGN THAT
 PROTECTS THE PENETRATION ACCORDING TO FMC 506.3.11.2.
  
 2) SHOW A DETAIL OF THIS NEW UL103 HT DUCT WHERE IT
 ENTERS THE EXISTING SHAFT. HOW WILL THIS BE ENCLOSED?
 FMC 607.5.5 EXCEPTION NUMBER 5.
  
 3) PROVIDE THE LENGTH OF EACH DUCT ON THE DRAWING. FBC
 107.3.5 AND 607.5.5.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2023-04-19 Cont ID  
Sent By medwards Date 2023-04-19 Time 10:25 Rev Time 0.00
Received By medwards Date 2023-04-19 Time 10:25 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2023-04-12 Cont ID  
Sent By medwards Date 2023-04-12 Time 10:47 Rev Time 0.00
Received By medwards Date 2023-04-12 Time 10:47 Sent To  
Notes
2023-04-12 10:49:02DRAWINGS SUBMITTED ARE COPIES OF THE ORIGINAL SO THE
 DIGITAL SIGNATURE HAS BEEN REMOVED. PROVIDE THE
 ORIGINALL DIGITALLY SIGNED DRAWINGS. FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-03-24 Cont ID  
Sent By medwards Date 2023-03-24 Time 09:41 Rev Time 0.00
Received By medwards Date 2023-03-24 Time 09:41 Sent To  
Notes
2023-03-24 09:42:38THE H-2 SHEET WILL NEED THE EOR TO DIGITALLY SIGN THE
 DRAWING. FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-03-08 Cont ID  
Sent By medwards Date 2023-03-08 Time 09:02 Rev Time 0.00
Received By medwards Date 2023-03-08 Time 09:02 Sent To  
Notes
2023-03-08 09:04:27THE DESIGNER OF THE DRAWINGS MUST INCLUDE THEIR DIGITAL
 SIGNATURE. 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  