Plan Review Details - Permit 23021049
Plan Review Stops For Permit 23021049
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-10 Cont ID  
Sent By cthroop Date 2023-03-10 Time 15:58 Rev Time 0.00
Received By cthroop Date 2023-03-10 Time 15:25 Sent To  
Notes
2023-03-10 16:00:021ST BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 1. PROVIDE A SITE PLAN W/BOUNDRY LINE SURVEY. IDENTIFY
 LOCATION OF WORK.
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE
 SITE,... AND IT SHALL BE DRAWN IN ACCORDANCE WITH AN
 ACCURATE AND INCLUDED BOUNDRY LINE SURVEY.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-10 Cont ID  
Sent By cthroop Date 2023-03-10 Time 16:00 Rev Time 0.00
Received By cthroop Date 2023-02-23 Time 07:34 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2023-03-10 Cont ID  
Sent By cthroop Date 2023-03-10 Time 15:58 Rev Time 0.00
Received By cthroop Date 2023-03-10 Time 15:25 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2023-03-10 Cont ID  
Sent By CIbaven Date 2023-03-10 Time 13:16 Rev Time 0.00
Received By cibaven Date 2023-03-10 Time 13:16 Sent To  
Notes
2023-03-10 13:16:40PER SEC. 94-304, PLEASE PROVIDE THE TOTAL FLOOR AREA OF
 THE ACCESSORY STRUCTURE, UTILITY SHED, AND THE GROSS
 FLOOR AREA OF THE PRIMARY STRUCTURE (HOUSE) ON THE LOT.
 PLEASE NOTE, THE TOTAL FLOOR AREA OF THE ACCESSORY
 STRUCTURE SHALL NOT EXCEED 75 PERCENT OF THE GROSS
 FLOOR AREA OF THE PRIMARY STRUCTURE WITH A MAXIMUM
 FLOOR AREA OF 1,000 SQUARE FEET.
  
 THE ACCESSORY STRUCTURE MUST BE SETBACK FROM REAR OF
 THE PROPERTY LINE 5 FEET OR 15 FEET FROM THE CENTERLINE
 OF THE ALLEY, WHICHEVER IS GREATER. IN ADDITION, THE
 ACCESSORY STRUCTURE MUST BE SETBACK 5 FEET FROM THE
 WEST SIDE OF THE PROPERTY LINE. PLEASE PROVIDE A SITE
 PLAN SHOWING SETBACK DIMENSIONS FROM PROPERTY LINES OR
 CENTERLINE OF THE ALLEY TO THE ACCESSORY STRUCTURE.
  
 PER SEC. 94-84, THE MAXIMUM LOT COVERAGE FOR ALL
 STRUCTURES ON THE PROPERTY FOR LOTS 5,000 TO 7,499
 SQUARE FEET IS 30 PERCENT. PLEASE SHOW AREAS OF ALL
 STRUCTURES ON THE LOT TO SHOW THAT THE TOTAL OF ALL
 AREAS ARE LESS THAN 30 PERCENT OF THE LOT AREA.
  
  
 CLAUDIA D. IBAVEN
 CITY URBAN DESIGNER / ZONING AND PLANNING
 [email protected]
 561-822-1402


Account Summary | Usage Policy | Privacy Policy