Plan Review Details - Permit 23020859
Plan Review Stops For Permit 23020859
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2023-02-24 Cont ID  
Sent By cpuell Date 2023-02-24 Time 14:48 Rev Time 0.00
Received By cpuell Date 2023-02-24 Time 14:48 Sent To  
Notes
2023-02-24 14:49:24WORK IS BEING DONE ON BOUTH THE NORTH AND SOUTH
 BUILDING, UPDATED PERMIT TO REFLECT THE TWO ADDRESSES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-07-17 Cont ID  
Sent By lbond Date 2023-07-17 Time 16:46 Rev Time 0.00
Received By lbond Date 2023-07-17 Time 16:46 Sent To  
Notes
2023-07-17 17:19:31FBC 107.2.1.
  
  
 1. WHAT ARE THE PROPERTIES OF THIS EXISITING GARAGE
 DOOR? IS IT INSULATED, IMPACT RESISTANT, OPERABLE?
 FIXED?
  
 2. HOW IS THIS DETACHED BUILDING INSULATED?
  
 3.CLARIFY HOW THIS BEDROOM IN THE PROPOSED FLOOR PLAN
 WILL HAVE A MIN 5 S.F. REQUIRED EGRESS WINDOW BY CODE
 FBC 1030.2?
  
 4.HOW DO YOU ACCESS THE BATHROOM FORM THE BEDROOM? I
 SEE A SOLID WALL AND NO DOOR.
  
 PLEASE ANSWER EACH COMMENT WITH A NARRATIVE.
 ANY QUESTIONS OR CONCERNS,
  
 PLEASE REACH OUT:
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-04-27 Cont ID  
Sent By lbond Date 2023-04-27 Time 09:09 Rev Time 0.00
Received By lbond Date 2023-04-27 Time 09:09 Sent To  
Notes
2023-04-27 09:12:38PREVIOUS COMMENTS NOT ANSWERED.
  
 PROVIDE BUIILDING 2 FLOOR PLAN AND ELEVATIONS-EXISTING
 DEMO AND PROPOSED.
 FPC PRODUCT APPROVAL FOR ALL NEW WINDOWS AND DOORS.
 PLEASE REPLY TO ALL COMMENTS WITH A NARRATIVE.
  
 THANK YOU
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-06 Cont ID  
Sent By lbond Date 2023-03-06 Time 16:47 Rev Time 0.00
Received By lbond Date 2023-03-06 Time 16:47 Sent To  
Notes
2023-03-06 16:52:36BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 22120266
  
 REVIEWED: MARCH 6, 2023
  
 FLORIDA BUILDING CODE,7TH EDITION (2020)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC BUILDING
 FBC EXISTING BUILDING
  
 COMMENTS:
  
 AS PER SECTION 107.2.1
 1)PROVIDE SUPPORTING DOCUMENTS FOR NOA OR FPA APPROVED
 FOR NEW WINDOW REPLACING GARAGE DOOR IN BUILDING 2
 2)CLEARLY DEFINE SCOPE OF WORK FOR BUILDING 2; INCLUDE
 GARAGE DOOR INFILL DETAILS.
  
 IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT
 HESITATE TO CONTACT ME
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
  
 NOTES:
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2023-07-17 Cont ID  
Sent By mpeterso Date 2023-07-17 Time 14:49 Rev Time 0.00
Received By mpeterso Date 2023-07-17 Time 13:58 Sent To  
Notes
2023-07-17 14:50:36ELECTRIC REVIEW FAILED
 PROVIDED A WRITTEN NARRATIVE HOW THE BELOW COMMENTS
 WILL BE ADDRESSED.
 1) SITE PLAN IDENTIFYING ALL STRUCTURES. FBC 107.2 NOT
 ADDRESSED
  
 2) A NARRATIVE WORK SCOPE FOR EACH STRUCTURE. FBC 107.2
 PARTIALLY ADDRESSED. PLANS STATE REPLACE WIRING AS
 NEEDED. PLAN REVIEW REQUIRES MORE SPECIFICITY. WHICH
 WIRING IS TO BE REPLACED AND WHICH IS TO REMAIN? NO
 SWITCHES OR OUTLETS ARE INDICATED AS REMAINING OR TO BE
 REPLACED, IF ALL ARE TO BE REPLACED THEN STATE IT.
  
 3) A SITE PLAN LOCATING ALL METERS, DISCONNECTS,
 ELECTRIC PANELS, AIR CONDITIONING EQUIPMENT AND ALL
 OTHER RELEVANT ELECTRICAL EQUIPMENT. LABEL ALL
 EQUIPMENT AS APPLICABLE. IF THERE IS MORE THAN ONE,
 LABEL THEM ACCORDINGLY AS A, B, C ETC.. NEC 215.5 AND
 FBC 107.2
 NOT ADDRESSED
  
 4) PROVIDE A RISER DIAGRAM DETAILING ALL METERS,
 DISCONNECTS, ELECTRIC PANELS AND SUBPANELS. INCLUDE ALL
 CONDUIT, CONDUCTOR AND EQUIPMENT SIZES. INCLUDE ALL
 GROUNDING ELECTRODE SYSTEMS. INCLUDE ALL NEW PROPOSED
 EQUIPMENT AND SUB PANELS. THERE IS A SUBMITTAL FOR A
 NEW POOL INSTALLATION THAT DETAILS ADDITIONAL ELECTRIC
 LOADS TO BE INSTALLED. IF THIS IS A SUB PANEL, INCLUDE
 THIS IN THE RISER. NEC 215.5 AND FBC 107.2
 NOT ADDRESSED. FLOOR PLANS DETAIL 2 ELECTRIC PANELS IN
 ONE STRUCTURE AND 1 IN THE OTHER. RISER DETAILS A METER
 AND 2 ELECTRIC PANELS. PLEASE PROVIDE A CORRECT
 ELECTRIC RISER DIAGRAM. 2/0 CU WIRE IS DETAILED
 INCORRECTLY FOR A 225 AMP PANEL. THIS WIRE HAS AN
 AMPACITY OF 175 AMPS. #6 CU WIRE IS DETAILED FOR A 125
 AMP PANEL WITH A 100 AMP BREAKER AS OVERCURRENT
 PROTECTION. #6 WIRE HAS AN AMPACITY OF 65 AMPS.
 ELECTRIC FLOOR PLAN DOES NOT DETAIL ELECTRIC METER OR
 PROPOSED POOL EQUIPMENT.
  
 5) PROVIDE ALL PANEL SCHEDULES WITH ALL ELECTRIC LOADS
 LISTED. NEC 215.5 AND FBC 107.2
 NOT ADDRESSED. SUBMITTAL IS STILL UNCLEAR WHERE AND HOW
 MANY ELECTRIC PANELS EXIST.
  
 6) PROVIDE SPECIFICATIONS FOR ALL EQUIPMENT. INCLUDE
 ALL AIR CONDITIONING, WATER HEATERS, PUMPS, RANGES AND
 OTHER ELECTRIC APPLIANCES. NEC 215.5 AND FBC 107.2
 NOT ADDRESSED
  
 7) PROVIDE AN ACCURATE LOAD CALCULATION FOR EACH PANEL.
 NEC 215.5 AND FBC 107.2
 NOT ADDRESSED. SUBMITTAL LACKS CLARITY. SEE PRIOR
 COMMENTS.
  
 8) PROVIDE AN ELECTRIC LOAD CALCULATION FOR THE ENTIRE
 SERVICE USING ONE OF THE TWO METHODS DESCRIBED IN NEC
 ARTICLE 220 (STANDARD OR OPTIONAL) DETAIL ON
 CALCULATION WHICH METHOD WAS USED. NEC 215.5 AND FBC
 107.2
 NOT ADDRESSED. SUBMITTAL LACKS CLARITY. CALCULATION
 METHOD IS NOT DETAILED. DETAIL ALL LOADS USED TO ARRIVE
 AT TOTAL GENERAL ELECTRICAL LOAD. SEE PRIOR COMMENTS.
  
 9) PROVIDE ELECTRIC FLOOR PLANS FOR BOTH STRUCTURES.
 INCLUDE ALL ELECTRIC OUTLETS, SWITCHES, RECEPTACLES,
 APPLIANCES AND OTHER ELECTRICAL WIRING AS OUTLINED IN
 NEC ARTICLE 210. FBC 107.2
 NOT ADDRESSED. SEE PRIOR COMMENTS. ONLY ONE SMALL
 APPLIANCE CIRCUIT IS DETAILED.
  
 FBC 107.2, CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2023-05-02 Cont ID  
Sent By mpeterso Date 2023-05-02 Time 14:08 Rev Time 0.00
Received By mpeterso Date 2023-05-02 Time 14:08 Sent To  
Notes
2023-05-02 14:11:29ELECTRIC REVIEW FAILED
  
 1) THIS SUBMITTAL WORK SCOPE IS VERY UNCLEAR. ONE, THIS
 IS FOR RENOVATION OF 2 STRUCTURES, HOWEVER ONLY ONE
 ELECTRIC PLAN WAS SUBMITTED. PLEASE PROVIDE THE
 FOLLOWING:
  
 1) SITE PLAN IDENTIFYING ALL STRUCTURES. FBC 107.2
  
 2) A NARRATIVE WORK SCOPE FOR EACH STRUCTURE. FBC 107.2
  
 3) A SITE PLAN LOCATING ALL METERS, DISCONNECTS,
 ELECTRIC PANELS, AIR CONDITIONING EQUIPMENT AND ALL
 OTHER RELEVANT ELECTRICAL EQUIPMENT. LABEL ALL
 EQUIPMENT AS APPLICABLE. IF THERE IS MORE THAN ONE,
 LABEL THEM ACCORDINGLY AS A, B, C ETC.. NEC 215.5 AND
 FBC 107.2
  
 4) PROVIDE A RISER DIAGRAM DETAILING ALL METERS,
 DISCONNECTS, ELECTRIC PANELS AND SUBPANELS. INCLUDE ALL
 CONDUIT, CONDUCTOR AND EQUIPMENT SIZES. INCLUDE ALL
 GROUNDING ELECTRODE SYSTEMS. INCLUDE ALL NEW PROPOSED
 EQUIPMENT AND SUB PANELS. THERE IS A SUBMITTAL FOR A
 NEW POOL INSTALLATION THAT DETAILS ADDITIONAL ELECTRIC
 LOADS TO BE INSTALLED. IF THIS IS A SUB PANEL, INCLUDE
 THIS IN THE RISER. NEC 215.5 AND FBC 107.2
  
 5) PROVIDE ALL PANEL SCHEDULES WITH ALL ELECTRIC LOADS
 LISTED. NEC 215.5 AND FBC 107.2
  
 6) PROVIDE SPECIFICATIONS FOR ALL EQUIPMENT. INCLUDE
 ALL AIR CONDITIONING, WATER HEATERS, PUMPS, RANGES AND
 OTHER ELECTRIC APPLIANCES. NEC 215.5 AND FBC 107.2
  
 7) PROVIDE AN ACCURATE LOAD CALCULATION FOR EACH PANEL.
 NEC 215.5 AND FBC 107.2
  
 8) PROVIDE AN ELECTRIC LOAD CALCULATION FOR THE ENTIRE
 SERVICE USING ONE OF THE TWO METHODS DESCRIBED IN NEC
 ARTICLE 220 (STANDARD OR OPTIONAL) DETAIL ON
 CALCULATION WHICH METHOD WAS USED. NEC 215.5 AND FBC
 107.2
  
 9) PROVIDE ELECTRIC FLOOR PLANS FOR BOTH STRUCTURES.
 INCLUDE ALL ELECTRIC OUTLETS, SWITCHES, RECEPTACLES,
 APPLIANCES AND OTHER ELECTRICAL WIRING AS OUTLINED IN
 NEC ARTICLE 210. FBC 107.2
  
 FBC 107.2, CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-03-07 Cont ID  
Sent By mpeterso Date 2023-03-07 Time 16:48 Rev Time 0.00
Received By mpeterso Date 2023-03-07 Time 15:28 Sent To  
Notes
2023-03-07 16:49:56ELECTRIC REVIEW FAILED
  
 1) PROVIDE A CORRECT ELECTRIC LOAD CALCULATION FOR
 PANEL A. THE ELECTRIC LOAD CALCULATION SUBMITTED
 INCORRECTLY LISTS THE, CALCULATED DEMAND LOAD, FROM
 PANEL B INSTEAD OF THE ACTUAL ELECTRIC LOADS. THE
 CORRECT CALCULATION WILL CALCULATE ALL LOADS FOR THE
 MAIN SERVICE FEEDERS FROM THE METER TO PANEL A,
 ACCORDING TO NEC 220.40, STANDARD CALCULATION OR
 220.80, OPTIONAL CALCULATION.
 2) BOTH RANGES ARE LISTED AS HAVING A LOAD OF 3KW, THE
 MINIMUM LOAD AS PER NEC 220.55 IS 8KW. PLEASE CORRECT
 LOAD CALCULATIONS FOR BOTH PANEL A AND B AS APPLICABLE
 3) PANEL B IS LISTED AS A 50 AMP PANEL, HOWEVER THE
 LOAD LISTED ON THE LOAD CALCULATION IS STATED AS
 28,6886 WATTS. 28886/240= 120 AMPS. PLEASE CORRECT THE
 PANEL SIZE AND FEEDERS AS APPLICABLE. NEC 215.2, FEEDER
 CONDUCTORS SHALL HAVE AN AMPACITY NOT LESS THAN
 REQUIRED TO SUPPLY THE LOAD AS CALCULATED
 4) PLEASE PROVIDE A WORK SCOPE AND ELECTRIC FLOOR PLAN
 FOR DWELLING WITH THE GARAGE. FBC 107.2
 FBC 107.2, CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL
 5) PROVIDE CORRECT ADDRESSES ON ALL PLANS FOR BOTH
 STRUCTURES. FBC 107.2
 6) CORRECTLY LABEL EACH ELECTRIC PANEL AS APPLICABLE.
 FBC 107.2
 7) PROVIDE AN ELECTRIC RISER THAT DETAILS THE CORRECT
 EQUIPMENT SIZES AND GROUNDING ELECTRODE SYSTEMS AS
 REQUIRED PER NEC 250.32 BUILDING(S) OR STRUCTURE(S)
 SUPPLIED BY FEEDER(S) OR BRANCH CIRCUIT(S) SHALL HAVE A
 GROUNDING ELECTRODE OR GROUNDING ELECTRODE SYSTEM
 INSTALLED
 8) PLEASE DETAIL THE REQUIRED OUTDOOR RECEPTACLES AT
 THE FRONT AND SIDE ENTRY OF THE HOUSE AS PER NEC
 210.52(E)(3)
 NEC 210.52(E)(3) BALCONIES, DECKS, AND PORCHES.
 BALCONIES, DECKS, AND PORCHES THAT ARE ATTACHED TO THE
 DWELLING UNIT AND ARE ACCESSIBLE FROM INSIDE THE
 DWELLING UNIT SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET
 ACCESSIBLE FROM THE BALCONY, DECK, OR PORCH.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  
  

Review Stop HIST HISTORICAL
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2023-06-01 Cont ID  
Sent By amhamilt Date 2023-06-01 Time 09:41 Rev Time 0.00
Received By amhamilt Date 2023-06-01 Time 09:41 Sent To  
Notes
2023-06-01 09:42:01THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 PREVIOUS COMMENTS NOT ADDRESSED SEE PREVIOUS COMMENTS.
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2023-04-03 Cont ID  
Sent By amhamilt Date 2023-04-03 Time 11:18 Rev Time 0.00
Received By amhamilt Date 2023-04-03 Time 11:18 Sent To  
Notes
2023-04-03 11:19:52THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 PLANS DO NOT SEEM TO ACCURATELY REFLECT EXISTING AND
 PROPOSED ELEVATIONS, PLEASE REVISE. PLEASE ALSO PROVIDE
 MORE DETAILS REGARDING WINDOWS (FRAME COLOR, GLASS
 COLOR). GARAGE DOOR CANNOT BE INFILLED, CAN BE REMOVED
 BUT MUST BE REPLACED TO STILL REFLECT THE VISIUAL
 APPEARANCE OF A GARAGE DOOR.
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By amcgrego Date 2023-07-14 Time 09:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-06-05 Cont ID  
Sent By jgomez Date 2023-06-05 Time 19:08 Rev Time 0.00
Received By jgomez Date 2023-04-26 Time 16:19 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-04-04 Cont ID  
Sent By aoliver Date 2023-04-04 Time 08:48 Rev Time 0.00
Received By aoliver Date 2023-02-24 Time 09:43 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2023-07-22 Cont ID  
Sent By cmontell Date 2023-07-22 Time 06:49 Rev Time 0.00
Received By cmontell Date 2023-07-22 Time 06:47 Sent To  
Notes
2023-07-22 06:49:27MECHANICAL PLAN REVIEW FAIL
  
 1) PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS
 FOR THE DETACHED HOUSE FBC 107.3.5
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 CHRIS MONTELLO
 561-805-6733
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2023-05-02 Cont ID  
Sent By medwards Date 2023-05-02 Time 11:55 Rev Time 0.00
Received By medwards Date 2023-05-02 Time 11:55 Sent To  
Notes
2023-05-02 11:56:252ND REVIEW FMC
 PERMIT: 23020859
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE REVISED SHEET A-4 SUBMITTED THIS CYCLE SHOWS THE
 DRYER LOCATION AND NEW MINI-SPLITS. PROVIDE THE ENERGY
 CALCULATIONS FOR THESE NEW MINI-SPLITS. PROVIDE THE
 MECHANICAL EQUIPMENT SIZING CALCULATIONS FOR THESE
 MINI-SPLITS. PROVIDE THE ANCHORING DETAILS FOR THE
 MINI-SPLIT CONDENSING UNIT. PROVIDE A MECHANICAL
 DRAWING SHOWING THESE CHANGES AND THE DRYER DUCT
 INCLUDING THE SIZE AND TERMINATION LOCATION. FBC
 107.3.5
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-02-27 Cont ID  
Sent By medwards Date 2023-02-27 Time 10:33 Rev Time 0.00
Received By medwards Date 2023-02-27 Time 10:33 Sent To  
Notes
2023-02-27 10:33:131ST REVIEW FMC
 PERMIT: 23020859
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) A MECHANICAL SUB-PERMIT WILL BE REQUIRED FOR THE
 DRYER DUCT LOCATION CHANGE. PROVIDE A NOTE ON THE
 DRAWING SPECIFYING THE DRYER DUCT MATERIAL AND
 TERMINATION LOCATION. FRC M1502
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status F Date 2023-07-17 Cont ID  
Sent By rwbrown Date 2023-07-17 Time 08:20 Rev Time 0.00
Received By rwbrown Date 2023-07-17 Time 08:20 Sent To  
Notes
2023-07-17 08:23:153RD PLUMBING REVIEW
  
 THERE WERE NO CHANGES FROM THE PREVIOUS REVIEW. PLEASE
 ADDRESS COMMENTS BELOW.
  
 1. 2020 FRC P3101.2.1 - THE ISOMETRIC DOES NOT SHOW
 COMPLIANT VENTING METHODS. EACH BATHROOM DOES NOT SHOW
 A VENT ANYWHERE ON THE HORIZONTAL BRANCH FOR EITHER
 BATHROOM. THE WASHING MACHINE ALSO DOES NOT SHOW A
 VENT. PLEASE SHOW A CODE COMPLIANT VENTING
 CONFIGURATION.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2023-04-27 Cont ID  
Sent By rwbrown Date 2023-04-27 Time 08:28 Rev Time 0.00
Received By rwbrown Date 2023-04-27 Time 08:28 Sent To  
Notes
2023-07-17 08:22:562ND PLUMBING REVIEW
  
 THERE WERE NO CHANGES FROM THE PREVIOUS REVIEW. PLEASE
 ADDRESS COMMENTS BELOW.
  
 1. 2017 WPB AMEND 107.3.5.3 (12) - - THE RISER
 SUBMITTED DOES NOT MATCH THE LAYOUT. THE WASHER AND
 DOUBLE SINK (KITCHEN?) ARE NOT NEXT TO EACH OTHER AS
 DEPICTED ON THE ISOMETRIC.
  
 2. 2017 WPB AMEND 107.3.5.3 (12) - THE RISER SHOWS THE
 TUB AND SHOWER DISCHARGING ABOVE (VERTICALLY) THE
 LAVATORY WHICH IS NOT POSSIBLE.
  
 PLEASE SUBMIT AN ISOMETRIC THAT MATCHES THE FLOOR PLAN
 AND MEETS CODE.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
  
2023-04-27 08:29:242ND PLUMBING REVIEW
  
 THERE WERE NO CHANGES FROM THE PREVIOUS REVIEW. PLEASE
 ADDRESS COMMENTS BELOW.
  
 1. 2017 WPB AMEND 107.3.5.3 (12) - - THE RISER
 SUBMITTED DOES NOT MATCH THE LAYOUT. THE WASHER AND
 DOUBLE SINK (KITCHEN?) ARE NOT NEXT TO EACH OTHER AS
 DEPICTED ON THE ISOMETRIC.
  
 2. 2017 WPB AMEND 107.3.5.3 (12) - THE RISER SHOWS THE
 TUB AND SHOWER DISCHARGING ABOVE (VERTICALLY) THE
 LAVATORY WHICH IS NOT POSSIBLE.
  
 PLEASE SUBMIT AN ISOMETRIC THAT MATCHES THE FLOOR PLAN
 AND MEETS CODE.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-02-27 Cont ID  
Sent By rwbrown Date 2023-02-27 Time 08:10 Rev Time 0.00
Received By rwbrown Date 2023-02-27 Time 08:10 Sent To  
Notes
2023-02-27 08:13:401ST PLUMBING REVIEW
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMEND 107.3.5.3 (12) - - THE RISER
 SUBMITTED DOES NOT MATCH THE LAYOUT. THE WASHER AND
 DOUBLE SINK (KITCHEN?) ARE NOT NEXT TO EACH OTHER AS
 DEPICTED ON THE ISOMETRIC.
  
 2. 2017 WPB AMEND 107.3.5.3 (12) - THE RISER SHOWS THE
 TUB AND SHOWER DISCHARGING ABOVE (VERTICALLY) THE
 LAVATORY WHICH IS NOT POSSIBLE.
  
 PLEASE SUBMIT AN ISOMETRIC THAT MATCHES THE FLOOR PLAN
 AND MEETS CODE.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2023-07-17 Cont ID  
Sent By lbond Date 2023-07-17 Time 16:41 Rev Time 0.00
Received By lbond Date 2023-07-17 Time 16:41 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2023-06-05 Cont ID  
Sent By jgomez Date 2023-06-05 Time 19:06 Rev Time 0.00
Received By jgomez Date 2023-06-05 Time 19:06 Sent To  
Notes
2023-06-05 19:08:05SIGNATURE REVIEW FOR ALL DRAWINGS SIGNED AND SEALED BY
 RONALD W GUSTAINUS PE AND FOR SHEET SD1 SIGNED AND
 SEALED BY GARY MCDOUGLE PE:
  
 1- ENGINEER'S DIGITAL SIGNATURE DOESN'T COMPLY WITH THE
 REQUIREMENTS OF FBPE. NEED A SEPARATE TEXT BOX WITH THE
 TEXT BOX LANGUAGE IDENTICAL TO THE SAMPLES SHOWN BY
 FBPE.
 SEE FBPE.ORG/LEGAL/SIGNING-AND-SEALING-ENGINEERING-DOCU
 MENTS/ AND REVISE DIGITAL SIGNATURE AS REQUIRED.
  
 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2023-06-06 Cont ID  
Sent By lbond Date 2023-04-27 Time 09:06 Rev Time 0.00
Received By lbond Date 2023-06-06 Time 16:48 Sent To  
Notes
2023-06-06 16:49:09SEE SIGNATURE REV 3 COMMENTS AND RESUBMIT
 THANKS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-03-06 Cont ID  
Sent By lbond Date 2023-03-06 Time 16:23 Rev Time 0.00
Received By lbond Date 2023-03-06 Time 16:23 Sent To  
Notes
2023-03-06 16:24:35ARCHITECT DIGITAL SIGNATURE FAILED
 ENGINEER STRUCTURAL ALTERATION OK

Review Stop Z ZONING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2023-05-24 Cont ID  
Sent By vbroglia Date 2023-05-24 Time 11:01 Rev Time 0.00
Received By vbroglia Date 2023-05-24 Time 11:01 Sent To  
Notes
2023-05-24 11:01:45LANDSCAPE PERMIT STILL REQUIRED, SEE PREVIOUS COMMENTS

Review Stop Z ZONING
Rev No 1 Status F Date 2023-04-03 Cont ID  
Sent By amhamilt Date 2023-04-03 Time 11:40 Rev Time 0.00
Received By amhamilt Date 2023-04-03 Time 11:40 Sent To  
Notes
2023-04-03 11:40:21THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S)
  
 THE VALUE OF THE CONSTRUCTION ($75,000.00) EXCEEDS 50%
 OF THE STRUCTURE'S VALUE ($112,344.00) ACCORDING TO THE
 P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT
 TO SECTION 94-441(B) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE
 IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN
 ARTICLE XIV OF THE ZLDR. SUBMIT A SEPARATE LANDSCAPE
 PERMIT WITH PLANS SHOWING MATERIAL EXISTING ON SITE OR
 ANY ADDITION OF TREES OR SHRUBS TO BRING THE SITE INTO
 CONFORMITY.
  
 REASON:
 FOR THE MAJORITY OF PROPERTIES, THE EXISTING LANDSCAPE
 IS NON-CONFORMING. THE MINIMAL CHARGE FOR A PERMIT
 VALUE OF LESS THAN $2500.00 IS $125.00. THIS ALLOWS FOR
 STAFF TO REVIEW THE EXISTING MATERIAL ON SITE TO VERIFY
 THE REQUIREMENTS ARE MET AND ALSO ALLOWS FOR AN
 INSPECTION TO CONFIRM THE SITE IS IN COMPLIANCE AT THE
 CONCLUSION OF THE PROJECT.
  
 ANNE HAMILTON
 HISTORIC PRESERVATION PLANNER
 [email protected]
 561.822.1428
  