| Plan Review Stops For Permit 23020784 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2023-06-26 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-26 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-26 |
Time |
08:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2023-06-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-14 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-14 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2023-06-14 12:59:10 | ROOFING | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE ADDITIONAL ENGINEERING FROM SANDRA PUERTA AR | | | DOES NOT SHOW AS DIGITALLY SIGNED IN ADOBE READER - | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-08 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-08 |
Time |
07:59 |
Sent To |
|
|
| Notes |
| 2023-06-08 10:09:27 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. PLEASE ADDRESS THE SIGNATURE REVIEW COMMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-22 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-22 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2023-05-22 15:42:32 | RE-ROOF BUILDING REVIEW COMMENTS | | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | | PERMIT #23020784 | | | 1500 FLORIDA AVE | | | | | | 1- FLAT ROOF NOA 21-1229.01 SUBMITTED: | | | A)SELECTED ASSEMBLY SYSTEM TYPE C(1) ON PAGE 7 OF 28 | | | CAN NOT BE USED. THIS ASSEMBLY IS LIMITED BY GENERAL | | | LIMITATION #9. THIS LIMITATION DOESN'T ALLOW NEITHER | | | RATIONAL ANALYSIS, NOT EXTRAPOLATION FOR ENHANCED | | | FASTENING. SEE GENERAL LIMITATION #9 ON LAST PAGE OF | | | NOA. NEED TO SELECT ANOTHER ASSEMBLY WITH GENERAL | | | LIMITATION #7 THAT ALLOW NAIL ENHANCEMENT CALCULATIONS. | | | SEC. 107.2.1 CITY AMENDMENTS. SEC. R301.2.1 | | | FBC-RESIDENTIAL. | | | | | | B)NAIL ENHANCEMENT CALCULATIONS SUBMITTED ARE FOR | | | ANOTHER NOA AND FOR ANOTHER ADDRESS 213 N WARE DR. | | | COORDINATE WITH ITEM 1(A) AND RESUBMIT. | | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | C) ROOF ZONES SPECIFIED ON THE CALCULATIONS SUBMITTED | | | ARE INCORRECT. ARCHITECT NEEDS TO USE THE REVISED ZONES | | | AND PROVIDE THE ZONES DIMENSIONS AS REQUIRED BY FIGURE | | | R301.2(7) FBC-RESIDENTIAL OF CURRENT 2020 CODE. | | | SEC. 107.2.1.2 CITY AMENDMENTS. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | | QUESTIONS REGARDING THESE COMMENTS, | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-20 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-20 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2023-04-20 11:30:44 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY | | | CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED PROFESSIONAL ENGINEER TO INCLUDE PRODUCT | | | APPROVAL SYSTEM NUMBER TO BE USED. | | | 2. FBC EB 706.8.1 PROVIDE A DETAILED COST ESTIMATE OF | | | THE EVALUATION AND INSTALLATION OF CONNECTIONS AT THE | | | GABLE ENDS OR ALL CORNERS THAT WILL EXCEED 15% OF THE | | | COST OF THE ROOF REPLACEMENT WHEN COMPLETED. SECOND | | | REQUEST. (CONTRACT PROPOSAL WAS UPLOADED NOT | | | ROOF-TO-WALL ESTIMATE) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-13 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-13 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-13 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2023-03-13 09:10:45 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1. SUBMITTED MIAMI-DADE COUNTY NOA NO. | | | 21-1229.01 SYSTEM TYPE C (1) MAXIMUM DESIGN PRESSURE | | | -52.5 PSF. DO NOT MEET THE MINIMUM ZONE 3 DESIGN | | | PRESSURE REQUIREMENT OF -108.17 FOR EXPOSURE CATEGORY C | | | AREAS. GENERAL LIMITATION #9 IS SPECIFICALLY REFERRED | | | TO IN THIS NOA. THE MAXIMUM DESIGNED PRESSURE | | | LIMITATION LISTED SHALL BE APPLICABLE TO ALL ROOF | | | PRESSURE ZONES (I.E. FIELD, PERIMETERS, AND CORNERS). | | | NEITHER RATIONAL ANALYSIS, NOR EXTRAPOLATION SHALL BE | | | PERMITTED FOR ENHANCED FASTENING AT ENHANCED PRESSURE | | | ZONES (I.E. PERIMETERS, EXTENDED CORNERS AND CORNERS). | | | THIS SYSTEM CAN???T BE USED. PROVIDE SYSTEM THAT MEETS | | | OR EXCEEDS THESE REQUIREMENTS. | | | 2. FBC EB 706.8.1 PROVIDE A DETAILED COST ESTIMATE OF | | | THE EVALUATION AND INSTALLATION OF CONNECTIONS AT THE | | | GABLE ENDS OR ALL CORNERS THAT WILL EXCEED 15% OF THE | | | COST OF THE ROOF REPLACEMENT WHEN COMPLETED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2023-03-13 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-13 |
Time |
09:10 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-13 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2023-03-13 09:11:28 | *FLAT ROOF ONLY* |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2023-06-26 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-26 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-15 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-06-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-14 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-13 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-08 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-01 |
Time |
08:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-22 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-15 |
Time |
17:23 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-20 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-12 |
Time |
18:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-13 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-13 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-10 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
P |
Date |
2023-06-26 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-26 |
Time |
13:52 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-26 |
Time |
08:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2023-06-14 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-06-14 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-06-14 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2023-06-14 12:59:53 | SIGNATURE REVIEW | | | | | | CORRECTIONS NEEDED - | | | | | | 1) THE ADDITIONAL ENGINEERING FROM SANDRA PUERTA AR | | | DOES NOT SHOW AS DIGITALLY SIGNED IN ADOBE READER - | | | SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE | | | DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN | | | ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | | SPECIFIC TYPE OF E-SIGNATURE). |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2023-06-08 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-06-08 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-06-08 |
Time |
10:03 |
Sent To |
|
|
| Notes |
| 2023-06-08 10:10:14 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | SUBMITTED SIGNED AND SEALED ENHANCED NAILING | | | CALCULATIONS IS A COPY OF A WET SIGNATURE. PLEASE | | | UPLOAD A VALID ELECTRONICALLY SIGNED PLAN/DOCUMENT TO | | | PROJECTDOX | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | | PLAN/DOCUMENT TO PROJECTDOX | | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | | BUILDING DEPRTMENT. | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-05-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2023-05-22 |
Time |
15:39 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2023-05-22 |
Time |
15:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-20 |
Time |
11:31 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-20 |
Time |
07:53 |
Sent To |
|
|
| Notes |
| 2023-04-20 11:31:28 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | PENDING REVISED ROOF COVERINGS ATTACHMENT CALCULATIONS | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | | PLAN/DOCUMENT TO PROJECTDOX | | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | | BUILDING DEPRTMENT. | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|