| Plan Review Stops For Permit 23020776 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-20 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-20 |
Time |
07:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
F |
Date |
2023-04-07 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-07 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-07 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2023-04-07 10:32:36 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY | | | CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA | | | REGISTERED PROFESSIONAL ENGINEER; TO CORRECT EXPOSURE | | | CATEGORY, DESIGN PRESSURES & NAILING PATTERNS. THE | | | CORRECT EXPOSURE CATEGORY FOR 234 DYER RD, WEST PALM | | | BEACH, FL 33405 IS EXPOSURE CATEGORY D. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2023-03-27 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-27 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-27 |
Time |
07:47 |
Sent To |
|
|
| Notes |
| 2023-03-27 12:49:03 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL16709-R10 SELECTED OPTION FOR SYSTEM NO W-5; | | | EXPOSURE (D); ENCLOSURE (ENCLOSED); ROOF HEIGHT (15 < H | | | < 20); ULTIMATE WIND SPEED (170). ZONE 3 IS MARKED | | | ???N/A??? WHICH INDICATES SYSTEM IS ???NOT | | | APPLICABLE??? TO ZONE1 PRIME DESIGN PRESSURE | | | REQUIREMENTS AND CANNOT BE USED. PLEASE PROVIDE 2020 | | | CODE VERSION PRODUCT APPROVAL/NOA THAT MEETS OR EXCEEDS | | | DESIGN PRESSURE REQUIREMENTS FOR EXPOSURE D AREAS. | | | SIGNED AND SEALED NAILING CALCULATIONS MAY BE REQUIRED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-03-15 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-15 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-15 |
Time |
07:33 |
Sent To |
|
|
| Notes |
| 2023-03-15 07:51:22 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL16709-R10 SELECTED OPTION FOR SYSTEM NO W-5; | | | EXPOSURE (D); ENCLOSURE (ENCLOSED); ROOF HEIGHT (H<15); | | | ULTIMATE WIND SPEED (160) IS NOT CORRECT. THE CORRECT | | | WIND SPEED FOR THE LISTED ADDRESS IS 170(MPH). PRODUCT | | | APPROVAL FL16709-R10 WILL NOT SATISFY EXPOSURE CATEGORY | | | D ENCLOSED AREAS WIND SPEED 170(MPH) WITHOUT USING | | | INSULATION OR PROVIDING ENGINEERED ENHANCED NAILING. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-03-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-03 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-03 |
Time |
13:38 |
Sent To |
|
|
| Notes |
| 2023-03-03 14:04:31 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL16709-R10 SELECTED OPTION FOR SYSTEM NO W-1 | | | EXPOSURE (D); ENCLOSURE (ENCLOSED); ROOF HEIGHT (15 < H | | | < 20); ULTIMATE WIND SPEED (160). ZONE 3 IS MARKED | | | ???N/A??? WHICH INDICATES SYSTEM IS ???NOT | | | APPLICABLE??? TO ZONE1 PRIME DESIGN PRESSURE | | | REQUIREMENTS AND CANNOT BE USED. PLEASE PROVIDE 2020 | | | CODE VERSION PRODUCT APPROVAL/NOA THAT MEETS OR EXCEEDS | | | DESIGN PRESSURE REQUIREMENTS FOR EXPOSURE D AREAS. | | | SIGNED AND SEALED NAILING CALCULATIONS MAY BE REQUIRED. | | | PRODUCT APPROVAL FL16709-R10 WILL NOT SATISFY EXPOSURE | | | CATEGORY D ENCLOSED AREAS WITHOUT USING INSULATION OR | | | PROVIDING ENGINEERED ENHANCED NAILING. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-02-16 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-02-16 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-02-16 |
Time |
08:04 |
Sent To |
|
|
| Notes |
| 2023-02-16 13:37:17 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | | APPROVAL FL16709-R10 SELECTED OPTION FOR SYSTEM NO W-5; | | | EXPOSURE (C); ENCLOSURE (ENCLOSED); ROOF HEIGHT (H<15); | | | ULTIMATE WIND SPEED (170) IS NOT CORRECT. THE CORRECT | | | EXPOSURE FOR THE LISTED ADDRESS IS EXPOSURE D. PRODUCT | | | APPROVAL FL16709-R10 WILL NOT SATISFY EXPOSURE CATEGORY | | | D ENCLOSED AREAS WITHOUT USING INSULATION OR PROVIDING | | | ENGINEERED ENHANCED NAILING. | | | 2. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF | | | DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING | | | CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S), | | | MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW | | | POSITIVE DRAINAGE. | | | 3. FBC EB 706.8. SHOW THAT THE VALUE OF THE STRUCTURE | | | IS LESS THAN $300,000.00 OR SPECIFY HOW THE ROOF TO | | | WALL CONNECTIONS WILL BE IMPROVED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-20 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-11 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2023-04-07 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-07 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-30 |
Time |
10:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2023-03-27 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-27 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-17 |
Time |
12:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-03-15 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-15 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-03-07 |
Time |
13:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-03-03 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-03-03 |
Time |
14:04 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-02-23 |
Time |
09:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-02-16 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-02-16 |
Time |
13:37 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-02-15 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-04-20 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-20 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-20 |
Time |
07:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-04-07 |
|
|
Cont ID |
|
| Sent By |
jbrooks |
Date |
2023-04-07 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
jbrooks |
Date |
2023-04-07 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2023-04-07 10:28:30 | JONATHAN BROOKS JR. | | | BUILDING PLANS EXAMINER | | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | | PHONE (561) 805-6656 | | | EMAIL: [email protected] | | | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | | RESULTS: DENIED | | | | | | SUBMITTED SIGNED AND SEALED ENHANCED NAILING | | | CALCULATIONS CAN NOT BE VERIFIED IT APPEARS TO BE A | | | COPY OF A DIGITALLY SIGNED DOCUMENT. PLEASE UPLOAD A | | | VALID ELECTRONICALLY SIGNED PLAN/DOCUMENT TO | | | PROJECTDOX. | | | | | | FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED | | | FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED | | | ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN | | | ORIGINAL. | | | PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED | | | PLAN/DOCUMENT TO PROJECTDOX | | | PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO | | | LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH | | | BUILDING DEPRTMENT. | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS, | | | 561-805-6656. | | | |
|
|