Plan Review Details - Permit 23020776
Plan Review Stops For Permit 23020776
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2023-04-20 Cont ID  
Sent By jbrooks Date 2023-04-20 Time 10:06 Rev Time 0.00
Received By jbrooks Date 2023-04-20 Time 07:49 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2023-04-07 Cont ID  
Sent By jbrooks Date 2023-04-07 Time 10:29 Rev Time 0.00
Received By jbrooks Date 2023-04-07 Time 07:42 Sent To  
Notes
2023-04-07 10:32:36JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1. REVISE SUBMITTED FASTENER DENSITY
 CALCULATIONS PREPARED, SIGNED AND SEALED BY A FLORIDA
 REGISTERED PROFESSIONAL ENGINEER; TO CORRECT EXPOSURE
 CATEGORY, DESIGN PRESSURES & NAILING PATTERNS. THE
 CORRECT EXPOSURE CATEGORY FOR 234 DYER RD, WEST PALM
 BEACH, FL 33405 IS EXPOSURE CATEGORY D.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2023-03-27 Cont ID  
Sent By jbrooks Date 2023-03-27 Time 12:48 Rev Time 0.00
Received By jbrooks Date 2023-03-27 Time 07:47 Sent To  
Notes
2023-03-27 12:49:03JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL16709-R10 SELECTED OPTION FOR SYSTEM NO W-5;
 EXPOSURE (D); ENCLOSURE (ENCLOSED); ROOF HEIGHT (15 < H
 < 20); ULTIMATE WIND SPEED (170). ZONE 3 IS MARKED
 ???N/A??? WHICH INDICATES SYSTEM IS ???NOT
 APPLICABLE??? TO ZONE1 PRIME DESIGN PRESSURE
 REQUIREMENTS AND CANNOT BE USED. PLEASE PROVIDE 2020
 CODE VERSION PRODUCT APPROVAL/NOA THAT MEETS OR EXCEEDS
 DESIGN PRESSURE REQUIREMENTS FOR EXPOSURE D AREAS.
 SIGNED AND SEALED NAILING CALCULATIONS MAY BE REQUIRED.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2023-03-15 Cont ID  
Sent By jbrooks Date 2023-03-15 Time 07:51 Rev Time 0.00
Received By jbrooks Date 2023-03-15 Time 07:33 Sent To  
Notes
2023-03-15 07:51:22JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL16709-R10 SELECTED OPTION FOR SYSTEM NO W-5;
 EXPOSURE (D); ENCLOSURE (ENCLOSED); ROOF HEIGHT (H<15);
 ULTIMATE WIND SPEED (160) IS NOT CORRECT. THE CORRECT
 WIND SPEED FOR THE LISTED ADDRESS IS 170(MPH). PRODUCT
 APPROVAL FL16709-R10 WILL NOT SATISFY EXPOSURE CATEGORY
 D ENCLOSED AREAS WIND SPEED 170(MPH) WITHOUT USING
 INSULATION OR PROVIDING ENGINEERED ENHANCED NAILING.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-03-03 Cont ID  
Sent By jbrooks Date 2023-03-03 Time 14:04 Rev Time 0.00
Received By jbrooks Date 2023-03-03 Time 13:38 Sent To  
Notes
2023-03-03 14:04:31JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL16709-R10 SELECTED OPTION FOR SYSTEM NO W-1
 EXPOSURE (D); ENCLOSURE (ENCLOSED); ROOF HEIGHT (15 < H
 < 20); ULTIMATE WIND SPEED (160). ZONE 3 IS MARKED
 ???N/A??? WHICH INDICATES SYSTEM IS ???NOT
 APPLICABLE??? TO ZONE1 PRIME DESIGN PRESSURE
 REQUIREMENTS AND CANNOT BE USED. PLEASE PROVIDE 2020
 CODE VERSION PRODUCT APPROVAL/NOA THAT MEETS OR EXCEEDS
 DESIGN PRESSURE REQUIREMENTS FOR EXPOSURE D AREAS.
 SIGNED AND SEALED NAILING CALCULATIONS MAY BE REQUIRED.
 PRODUCT APPROVAL FL16709-R10 WILL NOT SATISFY EXPOSURE
 CATEGORY D ENCLOSED AREAS WITHOUT USING INSULATION OR
 PROVIDING ENGINEERED ENHANCED NAILING.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-02-16 Cont ID  
Sent By jbrooks Date 2023-02-16 Time 13:33 Rev Time 0.00
Received By jbrooks Date 2023-02-16 Time 08:04 Sent To  
Notes
2023-02-16 13:37:17JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL16709-R10 SELECTED OPTION FOR SYSTEM NO W-5;
 EXPOSURE (C); ENCLOSURE (ENCLOSED); ROOF HEIGHT (H<15);
 ULTIMATE WIND SPEED (170) IS NOT CORRECT. THE CORRECT
 EXPOSURE FOR THE LISTED ADDRESS IS EXPOSURE D. PRODUCT
 APPROVAL FL16709-R10 WILL NOT SATISFY EXPOSURE CATEGORY
 D ENCLOSED AREAS WITHOUT USING INSULATION OR PROVIDING
 ENGINEERED ENHANCED NAILING.
 2. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF
 DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING
 CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S),
 MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW
 POSITIVE DRAINAGE.
 3. FBC EB 706.8. SHOW THAT THE VALUE OF THE STRUCTURE
 IS LESS THAN $300,000.00 OR SPECIFY HOW THE ROOF TO
 WALL CONNECTIONS WILL BE IMPROVED.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2023-04-20 Cont ID  
Sent By jbrooks Date 2023-04-20 Time 10:06 Rev Time 0.00
Received By jbrooks Date 2023-04-11 Time 10:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2023-04-07 Cont ID  
Sent By jbrooks Date 2023-04-07 Time 10:32 Rev Time 0.00
Received By jbrooks Date 2023-03-30 Time 10:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-03-27 Cont ID  
Sent By jbrooks Date 2023-03-27 Time 12:49 Rev Time 0.00
Received By jbrooks Date 2023-03-17 Time 12:25 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-03-15 Cont ID  
Sent By jbrooks Date 2023-03-15 Time 07:51 Rev Time 0.00
Received By jbrooks Date 2023-03-07 Time 13:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-03 Cont ID  
Sent By jbrooks Date 2023-03-03 Time 14:04 Rev Time 0.00
Received By jbrooks Date 2023-02-23 Time 09:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-02-16 Cont ID  
Sent By jbrooks Date 2023-02-16 Time 13:37 Rev Time 0.00
Received By jbrooks Date 2023-02-15 Time 15:52 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-04-20 Cont ID  
Sent By jbrooks Date 2023-04-20 Time 10:06 Rev Time 0.00
Received By jbrooks Date 2023-04-20 Time 07:50 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-04-07 Cont ID  
Sent By jbrooks Date 2023-04-07 Time 10:28 Rev Time 0.00
Received By jbrooks Date 2023-04-07 Time 10:28 Sent To  
Notes
2023-04-07 10:28:30JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
  
 SUBMITTED SIGNED AND SEALED ENHANCED NAILING
 CALCULATIONS CAN NOT BE VERIFIED IT APPEARS TO BE A
 COPY OF A DIGITALLY SIGNED DOCUMENT. PLEASE UPLOAD A
 VALID ELECTRONICALLY SIGNED PLAN/DOCUMENT TO
 PROJECTDOX.
  
 FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN
 ORIGINAL.
 PLEASE UPLOAD A VALID ELECTRONICALLY SIGNED
 PLAN/DOCUMENT TO PROJECTDOX
 PAPER PLANS/DOCUMENTS FOR SIGNATURE REVIEW WILL NO
 LONGER BE ACCEPTED BY THE CITY OF WEST PALM BEACH
 BUILDING DEPRTMENT.
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,
 561-805-6656.
  