Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-06-06 Cont ID  
Sent By jbrooks Date 2023-06-06 Time 12:20 Rev Time 0.00
Received By jbrooks Date 2023-06-06 Time 08:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-05-26 Cont ID  
Sent By pvalenti Date 2023-05-26 Time 16:10 Rev Time 0.00
Received By pvalenti Date 2023-05-26 Time 15:33 Sent To  
Notes
2023-05-26 16:10:22PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 BUILDING REVIEW DENIED:
  
 FBC B 107.2.1, PLEASE INDICATE WITHIN THE NOA
 (#20-0723.29) THE SYSTEM THAT WILL BE USED. THE SYSTEM
 THAT APPEARS TO HAVE BEEN SELECTED DOES NOT APPEAR TO
 MEET THE WINDLOAD PRESSURE REQUIREMENTS. PLEASE REVIEW,
 EVALUATE, & SELECT THE DIFFERENT SYSTEMS THAT WILL MEET
 THE WINDLOAD PRESSURE REQUIREMENTS FOR ALL ROOF ZONES
 SUCH AS SYSTEM # E-24.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-30 Cont ID  
Sent By jbrooks Date 2023-03-30 Time 09:08 Rev Time 0.00
Received By jbrooks Date 2023-03-30 Time 07:36 Sent To  
Notes
2023-03-30 09:08:33JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. SUBMITTED MIAMI-DADE COUNTY NOA 20-0723.29 COVERS
 MULTIPLE ROOFING SYSTEMS TYPES A(1) THROUGH E(24).
 SELECT SYSTEM TO BE USED. ALL APPLICABLE DETAILS AND
 ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE PRODUCT
 APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS NOT
 SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED
 SITE-SPECIFIC ENGINEERING. ENGINEERED SIGNED AND SEALED
 CALCULATIONS MAY BE REQUIRED. PLEASE NOTE THIS IS AN
 EXPOSURE CATEGORY C AREA.
 2. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF
 DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING
 CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S),
 MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW
 POSITIVE DRAINAGE.
 3. FBC B 107.2.1 PROVIDE A ROOF DRAINAGE PLAN THAT
 COMPLIES WITH SECTION 903.4 OF THE 2020 FBC-RESIDENTIAL
 AND CHAPTER 11 OF THE 2020 FBC-PLUMBING.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-06-06 Cont ID  
Sent By jbrooks Date 2023-06-06 Time 12:20 Rev Time 0.00
Received By jbrooks Date 2023-05-31 Time 17:32 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-05-26 Cont ID  
Sent By pvalenti Date 2023-05-26 Time 16:18 Rev Time 0.00
Received By pvalenti Date 2023-05-17 Time 17:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-30 Cont ID  
Sent By jbrooks Date 2023-03-30 Time 09:08 Rev Time 0.00
Received By jbrooks Date 2023-03-28 Time 06:16 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved