Plan Review Details - Permit 23020529
Plan Review Stops For Permit 23020529
Review Stop AD ADDRESSING
Rev No 1 Status N Date 2023-03-09 Cont ID  
Sent By aoliver Date 2023-03-09 Time 09:07 Rev Time 0.00
Received By aoliver Date 2023-03-09 Time 09:07 Sent To  
Notes
***NONE***

Review Stop AFFIDAVIT PRIVATE PROVIDER AFFIDAVIT
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop AFFIDAVIT PRIVATE PROVIDER AFFIDAVIT
Rev No 1 Status P Date 2023-04-19 Cont ID  
Sent By cthroop Date 2023-04-19 Time 10:34 Rev Time 0.00
Received By cthroop Date 2023-04-19 Time 07:34 Sent To  
Notes
2023-04-19 10:43:42 
  
2023-03-13 12:40:29OK TO SEND TO STAFF AFTER HISTORIC, ZONING
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-06-05 Cont ID  
Sent By rmcdouga Date 2023-06-05 Time 14:27 Rev Time 0.00
Received By rmcdouga Date 2023-06-05 Time 14:27 Sent To  
Notes
2023-06-05 14:37:29BUILDING AUDIT FAILED.
  
 1) SUBMIT AN EVALUATION FROM A FLORIDA LICENSED
 ENGINEER OF THE EACH OF THE TWO EXISTING BUILDING'S
 ROOFS THAT VERIFIES THEY ARE CAPABLE OF SUPPORTING ALL
 SUPERIMPOSED LOADS FROM THE PROPOSED SOLAR SYSTEM.
 FBC-R 301.1
  
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-05-17 Cont ID  
Sent By jleahy Date 2023-05-17 Time 07:27 Rev Time 0.00
Received By jleahy Date 2023-05-17 Time 07:16 Sent To  
Notes
2023-05-17 07:33:20FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PAGE E-1
  
 1) COMPLIANCE WITH SECTION 250.32(A)(B) REQUIRED
  
 2) COMPLIANCE WITH SECTION 225.36 REQUIRED.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2023-04-07 Cont ID  
Sent By amhamilt Date 2023-04-07 Time 10:49 Rev Time 0.00
Received By amhamilt Date 2023-04-07 Time 10:49 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By lmarchan Date 2023-07-26 Time 16:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-06-05 Cont ID  
Sent By rmcdouga Date 2023-06-05 Time 14:38 Rev Time 0.00
Received By rmcdouga Date 2023-04-19 Time 11:39 Sent To  
Notes
2023-06-05 14:38:5323020529

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-04-19 Cont ID  
Sent By shill Date 2023-04-19 Time 10:43 Rev Time 0.00
Received By cthroop Date 2023-03-08 Time 10:01 Sent To  
Notes
2023-03-09 09:08:22REMOVED BUILD & ELECT STOPS - PP PLAN REVIEW AND
 INSPECTIONS -AO

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 3 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 2 Status P Date 2023-05-23 Cont ID  
Sent By rgathrig Date 2023-05-23 Time 17:48 Rev Time 0.00
Received By rgathrig Date 2023-05-23 Time 17:48 Sent To  
Notes
2023-05-23 17:48:36PP DOCUMENT REVIEW APPROVED
  
 RICHARD GATHRIGHT
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status F Date 2023-03-14 Cont ID  
Sent By jbaker Date 2023-03-14 Time 07:32 Rev Time 0.00
Received By jbaker Date 2023-03-14 Time 07:28 Sent To  
Notes
2023-03-14 07:34:11THERE IS NO VERBIAGE IN THE BOX ENTITLED DESCRIPTION OF
 OPERATIONS PER FS 553.791 THAT SPELLS OUT A CERTIFICATE
 OF INSURANCE DEMONSTRATING THAT PROFESSIONAL
 LIABILITY INSURANCE COVERAGE IS IN PLACE FOR THE
 PRIVATE PROVIDER???S FIRM, THE PRIVATE PROVIDER, AND
 ANY DULY
 AUTHORIZED REPRESENTATIVE IN THE AMOUNTS REQUIRED BY
 THIS SECTION.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-04-19 Cont ID  
Sent By cthroop Date 2023-04-19 Time 10:30 Rev Time 0.00
Received By cthroop Date 2023-04-19 Time 07:34 Sent To  
Notes
2023-04-19 11:48:291ST SIGNATURE REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: ALL PLAN PAGES ???
  
 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND
 SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A
 VALID DIGITAL SIGNATURE.
 A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE
 IS NOT CONSIDERED A VALID DIGITAL SIGNATURE.
  
 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S.
 668.003 (3);
 FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
 F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS)
 F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS)
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
2023-04-19 10:34:12AFFIDAVIT IS NOTARIZED.
  
  

Review Stop Z ZONING
Rev No 2 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2023-04-17 Cont ID  
Sent By Vbroglia Date 2023-04-17 Time 13:01 Rev Time 0.00
Received By vbroglia Date 2023-04-17 Time 13:01 Sent To  
Notes
***NONE***