| Plan Review Stops For Permit 23020529 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-09 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-03-09 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-03-09 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AFFIDAVIT |
PRIVATE PROVIDER AFFIDAVIT |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AFFIDAVIT |
PRIVATE PROVIDER AFFIDAVIT |
| Rev No |
1 |
Status |
P |
Date |
2023-04-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-04-19 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-04-19 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2023-04-19 10:43:42 | | | | | | 2023-03-13 12:40:29 | OK TO SEND TO STAFF AFTER HISTORIC, ZONING | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-06-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-06-05 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-06-05 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2023-06-05 14:37:29 | BUILDING AUDIT FAILED. | | | | | | 1) SUBMIT AN EVALUATION FROM A FLORIDA LICENSED | | | ENGINEER OF THE EACH OF THE TWO EXISTING BUILDING'S | | | ROOFS THAT VERIFIES THEY ARE CAPABLE OF SUPPORTING ALL | | | SUPERIMPOSED LOADS FROM THE PROPOSED SOLAR SYSTEM. | | | FBC-R 301.1 | | | | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-05-17 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-05-17 |
Time |
07:27 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-05-17 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2023-05-17 07:33:20 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGE E-1 | | | | | | 1) COMPLIANCE WITH SECTION 250.32(A)(B) REQUIRED | | | | | | 2) COMPLIANCE WITH SECTION 225.36 REQUIRED. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-04-07 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-04-07 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-04-07 |
Time |
10:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-07-26 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-06-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2023-06-05 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2023-04-19 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2023-06-05 14:38:53 | 23020529 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-04-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-04-19 |
Time |
10:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-03-08 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2023-03-09 09:08:22 | REMOVED BUILD & ELECT STOPS - PP PLAN REVIEW AND | | | INSPECTIONS -AO |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2023-05-23 |
|
|
Cont ID |
|
| Sent By |
rgathrig |
Date |
2023-05-23 |
Time |
17:48 |
Rev Time |
0.00 |
| Received By |
rgathrig |
Date |
2023-05-23 |
Time |
17:48 |
Sent To |
|
|
| Notes |
| 2023-05-23 17:48:36 | PP DOCUMENT REVIEW APPROVED | | | | | | RICHARD GATHRIGHT | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2023-03-14 |
|
|
Cont ID |
|
| Sent By |
jbaker |
Date |
2023-03-14 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
jbaker |
Date |
2023-03-14 |
Time |
07:28 |
Sent To |
|
|
| Notes |
| 2023-03-14 07:34:11 | THERE IS NO VERBIAGE IN THE BOX ENTITLED DESCRIPTION OF | | | OPERATIONS PER FS 553.791 THAT SPELLS OUT A CERTIFICATE | | | OF INSURANCE DEMONSTRATING THAT PROFESSIONAL | | | LIABILITY INSURANCE COVERAGE IS IN PLACE FOR THE | | | PRIVATE PROVIDER???S FIRM, THE PRIVATE PROVIDER, AND | | | ANY DULY | | | AUTHORIZED REPRESENTATIVE IN THE AMOUNTS REQUIRED BY | | | THIS SECTION. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-04-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-04-19 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-04-19 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2023-04-19 11:48:29 | 1ST SIGNATURE REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | NOTICE: ALL PLAN PAGES ??? | | | | | | 1.DOCUMENTS PREPARED BY AN ARCHITECT OR ENGINEER AND | | | SUBMITTED ELECTRONICALLY FOR PUBLIC RECORD SHALL HAVE A | | | VALID DIGITAL SIGNATURE. | | | A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE | | | IS NOT CONSIDERED A VALID DIGITAL SIGNATURE. | | | | | | 2.SUBMIT PLANS WITH A VALID DIGITAL SIGNATURE PER F.S. | | | 668.003 (3); | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5). | | | F.S. 471; F.A.C. 61G15-23.005 (ENGINEERS) | | | F.S. 481; F.A.C. 61G1-16.005 (ARCHITECTS) | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | | | | | | 2023-04-19 10:34:12 | AFFIDAVIT IS NOTARIZED. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2023-04-17 |
|
|
Cont ID |
|
| Sent By |
Vbroglia |
Date |
2023-04-17 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-04-17 |
Time |
13:01 |
Sent To |
|
|
| Notes |
|
|