Plan Review Details - Permit 23020447
Plan Review Stops For Permit 23020447
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2023-02-18 Cont ID  
Sent By cpuell Date 2023-02-18 Time 08:19 Rev Time 0.00
Received By cpuell Date 2023-02-18 Time 08:19 Sent To  
Notes
2023-02-18 08:19:26ADDRESS APPROPRIATE FOR PROJECT.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2023-03-01 Cont ID  
Sent By aoliver Date 2023-03-01 Time 09:02 Rev Time 0.00
Received By aoliver Date 2023-03-01 Time 09:02 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2023-02-24 Cont ID  
Sent By lbond Date 2023-02-24 Time 10:36 Rev Time 0.00
Received By lbond Date 2023-02-24 Time 10:36 Sent To  
Notes
2023-02-24 10:35:46BUILDING REVIEW COMMENTS:
  
 W.P.B. PERMIT: 23020447
  
 REVIEWED: FEBRUARY 24, 2023
  
 FLORIDA BUILDING CODE,7TH EDITION (2020)
 FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK
 BELOW)
 HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/
 BUILDING-PERMIT-FORMS
 FBC BUILDING
 FBC EXISTING BUILDING
  
 COMMENTS:
  
 ASBESTOS REVIEW:
  
 FAILED PLAN REVIEW:
  
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
 HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC
 ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION
 -RENOVATION.HTML
  
 IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT
 HESITATE TO CONTACT ME
  
 LOUIS BOND, AIA
 BUILDING PLANS EXAMINER II
 DEVELOPMENT SERVICES DEPT.
 BUILDING DIVISION
 401 CLEMATIS STREET
 WEST PALM BEACH, FLORIDA 33401
 PH: 561-805-6729
 FX: 561-805-6676
 EMAIL: [email protected]
  
  
 NOTES:
 PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-02-24 Cont ID  
Sent By lbond Date 2023-02-24 Time 10:37 Rev Time 0.00
Received By lbond Date 2023-02-24 Time 10:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2023-02-22 Cont ID  
Sent By mpeterso Date 2023-02-16 Time 08:49 Rev Time 0.00
Received By mpeterso Date 2023-02-22 Time 12:59 Sent To  
Notes
2023-02-16 08:50:132/22/23 RECIEVED EMAIL FROM APPLICANT WITH LETTER AND
 PICTURES FROM EC STATING ALL ELECTRIC IS OFF. UPLOADED
 TO SUPPORTING DOCS FOLDER. CHANGED RESULT TO NOT
 REQUIRED MP
  
  
 2/16/23 SENT EMAIL REQUESTING ELECTRICAL APPLICATION.
 MP
  
 WEST PALM BEACH PLAN REVIEW NEEDS AN ELECTRICAL PERMIT
 APPLICATION FOR APPROVAL. THIS IS A BUILDING DEPARTMENT
 POLICY TO ENSURE ELECTRICAL SAFETY DURING DEMOLITION.
 PLEASE EMAIL THE ELECTRICAL PERMIT APPLICATION FROM A
 LICENSED ELECTRICAL CONTRACTOR TO [email protected],
 [email protected], AND [email protected] . WHEN WE
 RECEIVE THE APPLICATION THE ELECTRICAL REVIEWERS WILL
 APPROVE THE PLAN REVIEW.
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2023-02-17 Cont ID  
Sent By clfranci Date 2023-02-17 Time   Rev Time 0.00
Received By clfranci Date 2023-02-17 Time   Sent To  
Notes
2023-02-17 13:53:28THIS PLAN WAS REVIEWED AND PASSED BY CAITLIN L FRANCIS,
 FIRE INVESTIGATOR, WITH THE FOLLOWING PROVISO:
  
 THERE IS A NOTE ON THE PLAN INDICATING THERE WILL BE
 NEW FLOORING ADDED. PLEASE ENSURE THE FLOORING HAS
 SPECS SUBMITTED TO THE CITY FOR REVIEW IN ACCORDANCE
 WITH THE FOLLOWING:
  
 10.2.7.4 INTERIOR FLOOR FINISHES SHALL BE GROUPED IN
 THE CLASSES SPECIFIED
 IN 10.2.7.4.1 AND 10.2.7.4.2 IN ACCORDANCE WITH THE
 CRITICAL RADIANT FLUX
 REQUIREMENTS.
 10.2.7.4.1 CLASS I INTERIOR FLOOR FINISH. CLASS I
 INTERIOR FLOOR FINISH
 SHALL HAVE A CRITICAL RADIANT FLUX OF NOT LESS THAN
 0.45 W/CM2, AS DETERMINED
 BY THE TEST DESCRIBED IN 10.2.7.3.
 10.2.7.4.2 CLASS II INTERIOR FLOOR FINISH. CLASS II
 INTERIOR FLOOR FINISH
 SHALL HAVE A CRITICAL RADIANT FLUX OF NOT LESS THAN
 0.22 W/CM2, BUT LESS
 THAN 0.45 W/CM2, AS DETERMINED BY THE TEST DESCRIBED IN
 10.2.7.3.
  
 CAITLIN L FRANCIS
 FIRE INVESTIGATOR
 WEST PALM BEACH FIRE PREVENTION
 561-804-4728
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-01 Cont ID  
Sent By aoliver Date 2023-03-01 Time 09:02 Rev Time 0.00
Received By aoliver Date 2023-02-28 Time 12:49 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-02-24 Cont ID  
Sent By lbond Date 2023-02-24 Time 10:45 Rev Time 0.00
Received By lbond Date 2023-02-24 Time 11:17 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-02-24 Cont ID  
Sent By lbond Date 2023-02-24 Time 10:45 Rev Time 0.00
Received By lbond Date 2023-02-24 Time 10:45 Sent To  
Notes
***NONE***