| Plan Review Stops For Permit 23020399 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-05-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-15 |
Time |
06:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-09 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-04-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-04-04 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-04-04 |
Time |
06:37 |
Sent To |
|
|
| Notes |
| 2023-04-04 07:19:29 | 2ND BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1.PROVIDE THE FL PRODUCT APPROVAL COVER SHEETS FOR THE | | | PROPOSED WINDOWS AND EXT. DOORS. | | | THE COVER SHEET PROVIDES THE APPROVAL NUMBER, CODE | | | VERSION, AND STATUS, FBC R 301. | | | FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS, | | | EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS. | | | FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-03-07 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-03-07 |
Time |
06:32 |
Sent To |
|
|
| Notes |
| 2023-03-07 07:48:43 | 1ST BUILDING REVIEW | | | RESULTS: CORRECTIONS NEEDED | | | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | | PLANS EXAMINER II | | | CITY OF WEST PALM BEACH | | | (561) 805-6726 | | | [email protected] | | | | | | CODES IN EFFECT: | | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | NFPA 70 2017 EDITION NEC 2017 | | | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | | | 1. PROVIDE AN EXISTING FLOOR PLAN OF THE ENTIRE | | | STRUCTURE. IDENTIFY LOCATION OF WORK. (BUILDING AND | | | ELECTRICAL) | | | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. THE | | | EXAMINATION OF THE DOCUMENTS BY THE BUILDING OFFICIAL | | | SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA AND | | | DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION PLAN; | | | FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL | | | FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING | | | DIMENSIONS; AND ALL EXTERIOR ELEVATIONS: | | | (AS APPLICABLE) | | | | | | 2. INCLUDE A NARRATIVE (SCOPE OF WORK) FOR THE PROPOSED | | | WORK. (BUILDING AND ELECTRICAL) | | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-05-02 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-05-02 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2023-04-05 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-04-05 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-04-05 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2023-04-05 12:00:29 | ELECTRIC REVIEW FAILED | | | | | | 1) PREVIOUS COMMENT NOT ADDRESSED. PLEASE PROVIDE A | | | WORK SCOPE AND NOTE ON PLANS NEW VERSUS EXISTING WORK. | | | IF ALL ITEMS ON PLANS ARE NEW PLEASE STATE WITH A NOTE | | | ALL WORK DETAILED IS NEW AND IS TO COMPLY WITH ALL | | | CURRENT BUILDING AND ELECTRICAL CODES. FBC 107.2 | | | 2)PLEASE PROVIDE PRINTED NAME AND SIGNATURE OF THE | | | PERSON WHO PREPARED THE ELECTRICAL DESIGN SHALL BE ON | | | THE DRAWINGS- SEC. 107.2.1 WPB. PLEASE NOTE THAT AN | | | ELECTRICAL SUB-CONTRACTOR APPLICATION SHALL BE | | | SUBMITTED TO THE WPB BUILDING DEPT.- SEC. 105.1 WPB. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-02-14 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-02-14 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-02-14 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2023-02-14 12:09:38 | ELECTRIC PLAN REVIEW FAILED | | | | | | 1) PLEASE PROVIDE AN ELECTRIC FLOOR PLAN DETAILING ALL | | | ELECTRIC WORK. CLEARLY DISTINGUISH NEW WORK VERSUS WORK | | | THAT IS EXISTING AND TO REMAIN. PLEASE INCLUDE ALL | | | SWITCHES, RECEPTACLES, APPLIANCES, AIR CONDITIONING, | | | WATER HEATERS, ELECTRIC PANELS AND METERS. | | | | | | FBC 107.2, CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL | | | | | | 2) PLEASE PROVIDE AN ELECTRIC PANEL SCHEDULE DETAILING | | | ALL CIRCUITS REQUIRED, CONDUCTOR SIZES AND OVERCURRENT | | | PROTECTION FOR EACH CIRCUIT. PLEASE INDICATE WHETHER | | | CIRCUIT IS NEW OR EXISTING. | | | | | | FBC 107.2 AND NEC 215.5 | | | | | | 3) PLEASE PROVIDE AN ACCURATE ELECTRIC RISER DETAILING | | | ELECTRIC PANEL, CONDUIT, CONDUCTOR AND OVERCURRENT | | | PROTECTION SIZES. PLEASE INDICATE EQUIPMENT AS NEW OR | | | EXISTING. | | | | | | NEC 215.5 DIAGRAMS OF FEEDERS. IF REQUIRED BY THE | | | AUTHORITY HAVING JURISDICTION, A DIAGRAM SHOWING FEEDER | | | DETAILS SHALL BE PROVIDED PRIOR TO THE INSTALLATION OF | | | THE FEEDERS. | | | | | | 4) PLEASE INDICATE BY NOTE ALL NEW WIRING IS TO COMPLY | | | WITH NEC 210.8 FOR GFCI PROTECTION, NEC 210.12 ARC | | | FAULT PROTECTION, AND NEC 406.12 FOR TAMPER RESISTANT | | | RECEPTACLE REQUIREMENTS. | | | | | | 5) PROVIDE AN ELECTRIC LOAD CALCULATION DETAILING ALL | | | ELECTRIC LOADS, AND APPLIANCES SUCH AS WATER HEATERS, | | | RANGES, AIR CONDITIONING EQUIPMENT, ETC. | | | | | | NEC 220.40, THE CALCULATED LOAD OF A FEEDER OR SERVICE | | | SHALL NOT BE LESS THAN THE SUM OF THE LOADS ON THE | | | BRANCH CIRCUITS SUPPLIED | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2023-05-30 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-05-30 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-05-30 |
Time |
10:26 |
Sent To |
|
|
| Notes |
| 2023-05-30 10:27:04 | AS DISCUSSED, PLEASE ENSURE THAT *ONLY* DAMAGED WOOD IS | | | REPLACED, AND THAT REPLACEMENT WOOD IS IN MATCHING | | | WIDTH AND PROFILE TO EXISTING. | | | | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2023-04-24 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-04-24 |
Time |
12:40 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-04-24 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2023-04-24 12:41:52 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | PLEASE ADDRESS PREVIOUS COMMENT. | | | | | | PLEASE ALSO INDICATE ON WINDOW SCHEDULE FRAME COLOR, | | | (SHOULD BE WHITE) GLASS COLOR (SHOULD BE CLEAR) AND IF | | | ANY LOW E COATING WILL BE APPLIED TO WINDOWS (ONLY | | | PERMISSIBLE ON SIDES AND REAR) | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-03-23 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-03-23 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-03-23 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2023-03-23 12:09:39 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | PER SITE VISIT, PLEASE CONFIRM THAT ALL SIDING WILL BE | | | CAREFULLY REMOVED AND REUSED, WINDOWS WILL BE REPLACED | | | UNDER A SEPARATE PERMIT, AND ANY REPLACEMENT SIDING | | | WILL BE LOCATED TO THE REAR OR ON ENCLOSED CARPORT, AND | | | MATCHES IN WIDTH AND PROFILE TO EXISTING. PLEASE ALSO | | | PROVIDE MORE INFORMATION ON ANY REPLACEMENT SIDING | | | USED. | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-05-30 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-05-30 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-04-26 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-04-25 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-04-25 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-03-29 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-24 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-03-24 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-02-10 |
Time |
06:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2023-04-27 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-04-27 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-04-27 |
Time |
09:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2023-04-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-04-03 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-04-03 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2023-04-03 08:08:04 | 2ND REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 23020399 | | | 4/3/23 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET EP1: THE VENTING FOR THE BATH 3 FIXTURES IS | | | NOT IN COMPLIANCE WITH SECS. P3108.1 & P3108.2.1- | | | HORIZONTAL WET VENTING FBC RES. TO FIX THE PROBLEM | | | PROVIDE A VENT FOR THE LAVATORY FIXTURE DRAIN AND | | | EITHER VENT THROUGH THE ROOF OR CONNECT TO ANOTHER VENT | | | GOING THROUGH THE ROOF. | | | | | | 1) THE PRINTED NAME AND SIGNATURE OF THE PERSON WHO | | | PREPARED THE PLUMBING DESIGN SHALL BE ON THE DRAWINGS- | | | SEC. 107.2.1 WPB. PLEASE NOTE THAT A PLUMBING | | | SUB-CONTRACTOR APPLICATION SHALL BE SUBMITTED TO THE | | | WPB BUILDING DEPT.- SEC. 105.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-02-13 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-02-13 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2023-02-13 11:52:53 | 1ST REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 23020399 | | | 2/13/2023 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. PLEASE REVIEW COMMENT #1 | | | BELOW AND IF YOU HAVE QUESTIONS PLEASE CONTACT ME. | | | | | | 1) PLEASE PROVIDE THE SCOPE OF WORK FOR PLUMBING AND | | | GAS ON THE FLOOR PLAN OR ON A SEPARATE PLAN- SEC. | | | 107.2.1 WPB. PLEASE NOTE THAT RISER DRAWINGS ARE | | | REQUIRED FOR NEW SANITARY DRAINAGE AND VENT PIPING, AND | | | FOR NEW GAS PIPING INSTALLATIONS - SEC. 107.3.5.3 (12, | | | 13) WPB MINIMUM PLAN REVIEW CRITERIA FOR RESIDENTIAL | | | (ONE AND TWO FAMILY). | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
N |
Date |
2023-05-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-05-15 |
Time |
06:28 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-05-09 |
Time |
16:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
N |
Date |
2023-03-07 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2023-03-07 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2023-03-07 |
Time |
06:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-23 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-03-23 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-03-23 |
Time |
12:07 |
Sent To |
|
|
| Notes |
|
|