Plan Review Details - Permit 23020222
Plan Review Stops For Permit 23020222
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-03-07 Cont ID  
Sent By rmcphers Date 2023-03-07 Time 09:24 Rev Time 0.00
Received By rmcphers Date 2023-03-07 Time 09:24 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-02-23 Cont ID  
Sent By rmcphers Date 2023-02-23 Time 15:49 Rev Time 0.00
Received By rmcphers Date 2023-02-23 Time 15:40 Sent To  
Notes
2023-02-23 15:49:28SFR REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE PROVIDE AN EXTERIOR WINDOW AND DOOR FLASHING
 DETAIL - FBC R703.1.1 WATER RESISTANCE.
 THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND
 CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION
 OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A
 WATER-RESISTANT BARRIER BEHIND THE EXTERIOR CLADDING AS
 REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO
 THE EXTERIOR WATER THAT PENETRATES THE EXTERIOR
 CLADDING.
 EXCEPTIONS: 1. A WEATHER-RESISTANT EXTERIOR WALL
 ENVELOPE SHALL NOT BE REQUIRED OVER CONCRETE OR MASONRY
 WALLS DESIGNED IN ACCORDANCE WITH CHAPTER 6 AND FLASHED
 IN ACCORDANCE WITH SECTION R703.4.
  
 2) PLEASE SHOW THE REQUIRED SMOKE DETECTOR LOCATIONS -
 FBC R314.2.2 ALTERATIONS, REPAIRS AND ADDITIONS.
 WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS.
  
 3) SIGNED AND SEALED DRAWINGS DO NOT SHOW AS DIGITALLY
 SIGNED IN ADOBE READER - SIGNED AND SEALED DRAWINGS IN
 PROJECTDOX NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED
 TO BE USED IN ELECTRONIC PLAN REVIEW. (A
 CERTIFICATE-BASED DIGITAL SIGNATURE (OFTEN JUST CALLED
 A DIGITAL SIGNATURE) IS A SPECIFIC TYPE OF
 E-SIGNATURE).

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2023-03-06 Cont ID  
Sent By rperdomo Date 2023-03-06 Time 08:42 Rev Time 0.00
Received By rperdomo Date   Time   Sent To  
Notes
2023-03-06 08:45:06NO ELECTRICAL WORK WILL BE PERFORMED IN THE PROJECT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-02-10 Cont ID  
Sent By rperdomo Date 2023-02-10 Time 14:26 Rev Time 0.00
Received By rperdomo Date 2023-02-10 Time 14:16 Sent To  
Notes
2023-02-10 14:25:52FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. PLEASE PROVIDE ELECTRICAL SCOPE OF WORK (NO
 ELECTRICAL INFORMATION IS ON THE PLAN REVIEW). FBC
 107.2
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-07 Cont ID  
Sent By rmcphers Date 2023-03-07 Time 09:25 Rev Time 0.00
Received By rmcphers Date 2023-03-03 Time 16:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-02-23 Cont ID  
Sent By rmcphers Date 2023-02-23 Time 15:51 Rev Time 0.00
Received By rmcphers Date 2023-02-07 Time 08:10 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2023-03-06 Cont ID  
Sent By medwards Date 2023-03-06 Time 10:32 Rev Time 0.00
Received By medwards Date 2023-03-06 Time 10:32 Sent To  
Notes
2023-03-06 10:33:19NO MECHANICAL WORK IN THE SCOPE OF THIS PROJECT. ME

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-02-13 Cont ID  
Sent By medwards Date 2023-02-13 Time 17:26 Rev Time 0.00
Received By medwards Date 2023-02-13 Time 17:26 Sent To  
Notes
2023-02-13 17:28:07PROVIDE A COMPLETE SCOPE OF WORK FOR THE MECHANICAL
 SYSTEMS FOR THIS PROJECT INCLUDING DRAWINGS OF ALL
 MECHANICAL WORK. FBC 107.3.5
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2023-03-06 Cont ID  
Sent By ccole Date 2023-03-06 Time 09:06 Rev Time 0.00
Received By ccole Date 2023-03-06 Time 08:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2023-02-08 Cont ID  
Sent By ccole Date 2023-02-08 Time 13:33 Rev Time 0.00
Received By ccole Date 2023-02-08 Time 12:38 Sent To  
Notes
2023-02-08 13:34:191ST REVIEW FBC-2020 RES. PLUMBING
 PERMIT- 23020222
 2/8/23
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS D100 & A100: DEMO NOTE 8 INDICATES FLOORS IN
 THE BATHROOMS, KITCHEN AND LAUNDRY ROOM TO BE REMOVED
 HOWEVER NOTE 11 FOR REMOVAL OF PLUMBING FIXTURES IS NOT
 SHOWN ON THE FLOOR PLAN. PLEASE CLARIFY THE SCOPE OF
 WORK FOR THE PLUMBING FIXTURES- SEC. 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-03-07 Cont ID  
Sent By rmcphers Date 2023-03-07 Time 09:25 Rev Time 0.00
Received By rmcphers Date 2023-03-07 Time 09:25 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-02-23 Cont ID  
Sent By rmcphers Date 2023-02-23 Time 15:49 Rev Time 0.00
Received By rmcphers Date 2023-02-23 Time 15:49 Sent To  
Notes
2023-02-23 15:51:06SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) THE SIGNED AND SEALED DRAWINGS PROVIDED DO NOT SHOW
 AS DIGITALLY SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop Z ZONING
Rev No 1 Status P Date 2023-02-14 Cont ID  
Sent By avolcy Date 2023-02-14 Time 09:48 Rev Time 0.00
Received By avolcy Date 2023-02-14 Time 09:48 Sent To  
Notes
***NONE***