| Plan Review Stops For Permit 23020128 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-07-20 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-20 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-20 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-06-26 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-06-26 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-06-26 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2023-06-26 13:54:34 | BUILDING REVIEW COMMENTS FOR GARAGE PORTION: FAILED | | | | | | W.P.B. PERMIT:23020128 | | | | | | REVIEWED: 6.26.2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENTS: | | | | | | | | | SEE GARAGE PERMIT 23020129 FOR ADDITIONAL FEES | | | | | | SHEET A-1 | | | | | | 1. AS PER FBC 107.2.1 CLARIFY | | | DOOR TAGS ARE NOT COORDINATED WITH DOOR SCHEDULE. | | | PROVIDE NOA AND DESIGN PRESSURE FOR ALL NEW EXTERIOR | | | DOORS INCLUDING GARAGE DOORS IN THE SCHEDULE JUST LIKE | | | PRESENTED FOR THE WINDOWS. PLEASE UDATE AND RESUBMIT. | | | | | | END OF BUILIDNG COMMENTS | | | | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-02 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-02 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2023-05-02 11:30:19 | BUILIDNG PASSED FOR ADDITION ONLY | | | GARAGE UNDER SEPERATE PERMIT |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2023-07-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-07-28 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-07-28 |
Time |
10:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2023-06-30 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-06-30 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-06-30 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2023-06-30 08:26:10 | | | | PANEL "B IN GARAGE NEEDS A MAIN BREAKER PER 225.33 | | | | | | 225.33 MAXIMUM NUMBER OF DISCONNECTS. | | | (A) GENERAL. | | | | | | THE DISCONNECTING MEANS FOR EACH SUPPLY PERMITTED BY | | | 225.30 SHALL CONSIST OF NOT MORE THAN SIX SWITCHES OR | | | SIX CIRCUIT BREAKERS MOUNTED IN A SINGLE ENCLOSURE, IN | | | A GROUP OF SEPARATE ENCLOSURES, OR IN OR ON A | | | SWITCHBOARD OR SWITCHGEAR. THERE SHALL BE NO MORE THAN | | | SIX DISCONNECTS PER SUPPLY GROUPED IN ANY ONE LOCATION. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-05-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-05-15 |
Time |
10:07 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-05-15 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2023-05-15 10:07:29 | FLORIDA BUILDING CODE 2020 7TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | | NFPA 70 2017 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1) GARAGE PANEL NEEDS A GROUNDING ELECTRODE SYSTEM | | | 250.32 | | | | | | 250.32 BUILDINGS OR STRUCTURES SUPPLIED BY A FEEDER(S) | | | OR BRANCH CIRCUIT(S). | | | (A) GROUNDING ELECTRODE. | | | BUILDING(S) OR STRUCTURE(S) SUPPLIED BY FEEDER(S) OR | | | BRANCH CIRCUIT(S) SHALL HAVE A GROUNDING ELECTRODE OR | | | GROUNDING ELECTRODE SYSTEM INSTALLED IN ACCORDANCE WITH | | | PART III OF ARTICLE 250. THE GROUNDING ELECTRODE | | | CONDUCTOR(S) SHALL BE CONNECTED IN ACCORDANCE WITH | | | 250.32(B) OR (C). WHERE THERE IS NO EXISTING GROUNDING | | | ELECTRODE, THE GROUNDING ELECTRODE(S) REQUIRED IN | | | 250.50 SHALL BE INSTALLED. | | | | | | 2) GARAGE PANEL WILL NEED A MAIN BREAKER 225.33 | | | | | | 225.33 MAXIMUM NUMBER OF DISCONNECTS. | | | (A) GENERAL. | | | THE DISCONNECTING MEANS FOR EACH SUPPLY PERMITTED BY | | | 225.30 SHALL CONSIST OF NOT MORE THAN SIX SWITCHES OR | | | SIX CIRCUIT BREAKERS MOUNTED IN A SINGLE ENCLOSURE, IN | | | A GROUP OF SEPARATE ENCLOSURES, OR IN OR ON A | | | SWITCHBOARD OR SWITCHGEAR. THERE SHALL BE NO MORE THAN | | | SIX DISCONNECTS PER SUPPLY GROUPED IN ANY ONE LOCATION. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2023-06-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-26 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-26 |
Time |
08:31 |
Sent To |
|
|
| Notes |
| 2023-06-28 17:14:15 | GAS WATER HEATER REMOVED FROM PROJECT. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-05-02 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-05-02 |
Time |
11:55 |
Sent To |
|
|
| Notes |
| 2023-05-02 12:04:07 | 1ST REVIEW FBC-2020 RES. GAS | | | PERMIT- 23020128 | | | 5/2/23 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. PLEASE REVIEWTHE COMMENTS | | | AND NOTE THAT GAS CAN BE SUBMITTED UNFER A SEPARTATE | | | PERMIT BY REQUEST. | | | | | | 1) SHEET E-1 SHOWS A GAS FIRED TANKLESS WATER HEATER IN | | | THE PANEL SCHEDULE. PLEASE SUBMIT GAS PLANS- SEC. | | | 107.2.1 WPB. AT A MINIMUM A GAS RISER DRAWING IS | | | REQUIRED- SEC. 107.3.5.3 WPB. THE RISER SHALL INCLUDE | | | ALL NEW AND EXISTING GAS PIPING AND APPLIANCES AT THE | | | RESIDENCE- SECTION G2412.3 & G2412.4 FBC RES. REFER TO | | | FBC RES. CHAPTER 24 FUEL GAS- THE RISER SHALL INDICATE: | | | A) TYPE OF GAS- NATURAL OR LP. | | | B) DELIVERY PRESSURE AT THE METER. | | | C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS. | | | D) TYPES AND SIZES OF PIPING. | | | E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER | | | TO THE MOST REMOTE APPLIANCE OUTLET. | | | F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS. | | | G) LOCATIONS OF REGULATORS, SHUTOFF VALVES. | | | H) OUTLET PRESSURES AT REGULATORS. | | | I) LOCATIONS AND TYPES OF PIPE SLEEVES. | | | K) PIPE SIZING TABLES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-07-17 |
Time |
08:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-06-30 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-06-30 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-06-30 |
Time |
08:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-05-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-16 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-04-26 |
Time |
10:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-02 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-02 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2023-05-02 11:24:46 | | | | 109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC | | | IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON | | | NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR | | | WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE | | | WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY | | | UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | | YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE | | | R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU | | | ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE | | | UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2023-07-25 |
|
|
Cont ID |
|
| Sent By |
jbaker |
Date |
2023-07-25 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
jbaker |
Date |
2023-07-25 |
Time |
10:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2023-07-13 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-07-13 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-07-13 |
Time |
11:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2023-06-29 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-06-29 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-06-29 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2023-06-29 07:51:27 | PASS PROVISO | | | 1) REFER TO SECTION M1502.3 DRYER DUCT TERMINATION | | | 2020 FBC RESIDENTIAL. | | | 2) REFER TO SECTION M1502.3.1 DRYER DUCT TERMINATION | | | OUTLET AND PASSAGEWAY. 2020 FBC RESIDENTIAL. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-05-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2023-05-16 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2023-05-16 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2023-05-16 13:14:21 | PLAN DENIED | | | 1) MARK DUCT SIZE AND GRILL SIZE AND CFM ON ALLSUPPLY | | | DUCT. | | | MARK DUCT SIZE ON ALL RETURN AIR DUCT. SECTION 107 | | | WEST PALM BEACH AMENDMENTS. | | | 2) REFER TO SECTION M1502 CLOTHES DRYER EXHAUST. | | | SHOW TERMINATION OF DRYER DUCT. 2020 FBC RESIDENTIAL | | | CODE. | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2023-06-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-06-26 |
Time |
08:40 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-06-26 |
Time |
08:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2023-05-02 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2023-05-02 |
Time |
11:47 |
Sent To |
|
|
| Notes |
| 2023-05-02 11:55:20 | 1ST REVIEW FBC-2020 RES. PLUMBING | | | PERMIT- 23020128 | | | 5/2/23 | | | | | | CODES IN EFFECT: | | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | | 2020 | | | FS- FLORIDA STATUTES | | | FAC- FLORIDA ADMINISTRATIVE CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PLEASE SUBMIT PLUMBING PLANS- SEC. 107.2.1 WPB. AT A | | | MINIMUM A SANITARY RISER DRAWING IS REQUIRED- SEC. | | | 107.3.5.3 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL/PLUMBING PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2023-06-27 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-06-27 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-06-27 |
Time |
08:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-02 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-02 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2023-05-02 11:29:24 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23020128 | | | | | | REVIEWED: MAY 5,2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | ROOF COMMENTS: FAILED | | | | | | AS PER SECTION 107.2.1 | | | PROVIDE ALL FBC PRODUCT APPROVAL FOR NEW ROOF ASSEMBLY. | | | | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-07-20 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-07-20 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-07-20 |
Time |
14:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2023-06-26 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-06-26 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-06-26 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2023-06-26 13:46:33 | SEE PREVIOUS SIGNATURE COMMENT. | | | SHEET A-101 GOOD | | | M-1 GOOD | | | | | | REST NEEDS TO BE DIGITALLY VERIFIABLE. |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-05-02 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-05-02 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2023-05-02 11:26:39 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23020128 | | | | | | REVIEWED: MAY 2ND 2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENTS: | | | | | | PLANS BY FL. LICENSE ARCHITECT THAT ARE SUBMITTED | | | ELECTRONICALLY SHALL BEAR VERIFIABLE, ORIGINAL DIGITAL | | | SIGNATURE AND SEALS- FL STATUTE 471.025 AND SEC | | | 61G15-23.005 FLORIDA ADMINISTRATIVE CODE. | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2023-06-30 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-06-30 |
Time |
08:47 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-06-30 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2023-06-30 08:49:05 | FAILED | | | 6/30/2023 | | | | | | PLEASE LABEL THE SETBACK FROM THE PROPOSED ADDITION TO | | | THE REAR AND SIDE OF THE PROPERTY LINE. | | | | | | | | | ALEXIS SANGELEER | | | PLANNER | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
asangele |
Date |
2023-05-08 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
asangele |
Date |
2023-05-08 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2023-05-08 13:43:32 | FAILED | | | 5/8/2023 | | | | | | | | | PLEASE PROVIDE THE SETBACKS OF THE PROPOSED ADDITION ON | | | THE SITE PLAN/SURVEY. | | | | | | | | | A SEPARATE LANDSCAPE PERMIT IS REQURIED | | | THE VALUE OF THE CONSTRUCTION ($150,000) EXCEEDS 50% OF | | | THE STRUCTURE'S IMPROVEMENT VALUE ($159,055) ACCORDING | | | TO THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, | | | PURSUANT TO SECTION 94-441(B) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. SUBMIT A | | | SEPARATE LANDSCAPE PERMIT WITH PLANS SHOWING MATERIAL | | | EXISTING ON SITE OR ANY ADDITION OF TREES OR SHRUBS TO | | | BRING THE SITE INTO CONFORMITY. | | | | | | | | | | | | | | | ALEXIS SANGELEER | | | PLANNER | | | [email protected] |
|
|