Plan Review Details - Permit 23020090
Plan Review Stops For Permit 23020090
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-05-02 Cont ID  
Sent By cthroop Date 2023-05-02 Time 15:49 Rev Time 0.00
Received By cthroop Date 2023-05-02 Time 15:18 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-09 Cont ID  
Sent By cthroop Date 2023-03-09 Time 12:35 Rev Time 0.00
Received By cthroop Date 2023-03-09 Time 10:36 Sent To  
Notes
2023-03-09 12:38:501ST BUILDING REVIEW
 RESULTS: CORRECTIONS NEEDED
  
 CHRISTOPHER S. THROOP, CBO, BN, PX, CFM
 PLANS EXAMINER II
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT:
  
 NOTICE: VALUE ADJUSTED TO $47,831 PER THE ICC BUILDING
 VALUATION DATA.
  
 1. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3
 IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED BOUNDARY LINE SURVEY.
 FBC R401.3 SITE DRAINAGE
  
 2. PROVIDE AN ENERGY SUBMITTAL RESIDENTIAL (RE)
 R401.2COMPLIANCE.
 SECTION R405 AND THE PROVISIONS OF SECTIONS R401
 THROUGH R404 LABELED MANDATORY.
  
 3.PROVIDE SMOKE ALARMS.
 FBC 1104.1SMOKE ALARMS IN EXISTING PORTIONS OF A
 BUILDING.
  
 SMOKE ALARMS
 R314.2.2ALTERATIONS, REPAIRS AND ADDITIONS.
 WHERE ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHERE ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS. FBC R314.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2023-04-19 Cont ID  
Sent By rperdomo Date 2023-04-19 Time 14:28 Rev Time 0.00
Received By rperdomo Date   Time   Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2023-02-28 Cont ID  
Sent By rperdomo Date 2023-02-28 Time 15:01 Rev Time 0.00
Received By rperdomo Date 2023-02-28 Time 14:44 Sent To  
Notes
2023-02-28 15:01:06FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW
  
 1. SMOKE ALARMS (SMOKE DETECTION) SYSTEM AND CO (CARBON
 MONOXIDE) DETECTION SYSTEM SHALL BE PROVIDED IN
 ACCORDANCE WITH NFPA 72, FBC 907, IRC 314, IRC 315
  
 2. PRIVIDE PANEL SCHEDULE. NEC 408.4(A)
  
 END OF COMMENTS
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 RUBEN PEREZ PERDOMO, P.E.
 ELECTRICAL PLANS EXAMINER
 561-805-6738
 [email protected]
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2023-04-20 Cont ID  
Sent By lquinone Date 2023-04-20 Time 19:37 Rev Time 0.00
Received By lquinone Date 2023-04-20 Time 19:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-05-02 Cont ID  
Sent By cthroop Date 2023-05-02 Time 15:49 Rev Time 0.00
Received By cthroop Date 2023-04-11 Time 09:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-09 Cont ID  
Sent By cthroop Date 2023-03-09 Time 12:38 Rev Time 0.00
Received By cthroop Date 2023-02-14 Time 11:25 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2023-06-13 Cont ID  
Sent By aoliver Date 2023-06-13 Time 09:34 Rev Time 0.00
Received By aoliver Date 2023-05-10 Time 11:39 Sent To  
Notes
2023-05-10 11:39:485/10/23 EMAILED IMPACT OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2023-03-09 Cont ID  
Sent By cthroop Date 2023-03-09 Time 12:01 Rev Time 0.00
Received By cthroop Date 2023-03-09 Time 10:36 Sent To  
Notes
2023-03-09 12:02:32IMPACT FEES
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2023-04-19 Cont ID  
Sent By medwards Date 2023-04-19 Time 11:19 Rev Time 0.00
Received By medwards Date 2023-04-19 Time 11:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2023-02-21 Cont ID  
Sent By medwards Date 2023-02-21 Time 13:41 Rev Time 0.00
Received By medwards Date 2023-02-21 Time 13:41 Sent To  
Notes
2023-02-21 13:41:581ST REVIEW FMC
 PERMIT: 23020090
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THERE WERE 2 MECHANICAL PLANS SUBMITTED, 1 FROM
 ALEXANDER ROJAS WHICH SHOWED ONLY THE MECHANICAL DESIGN
 FOR THE NEW ADDITION. THE OTHER DRAWING WAS FROM AN
 UNKNOW AUTHOR AS IT WASN???T SIGNED BY THE DESIGNER.
 THIS DESIGN IS FOR THE ENTIRE HOUSE WHICH IS WHAT THE
 ENERGY CALCS AND MECHANICAL EQUIPMENT SIZING
 CALCULATIONS WAS FOR. HOW EVER THIS DRAWING IS NOT
 COMPLETE AS IT DOES NOT SHOW DOOR OR CASED OPENING. IT
 ALSO DOES NOT SHOW THE RETURN AIR PATH FROM ROOMS WITH
 DOORS BACK TO THE AHU. PROVIDE ONLY 1 COMPLETE DRAWING
 FOR THIS PROJECT. FBC 107.3.5
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2023-02-16 Cont ID  
Sent By rwbrown Date 2023-02-16 Time 12:05 Rev Time 0.00
Received By rwbrown Date 2023-02-16 Time 12:04 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2023-03-09 Cont ID  
Sent By cthroop Date 2023-03-09 Time 12:34 Rev Time 0.00
Received By cthroop Date 2023-03-09 Time 10:37 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-05-02 Cont ID  
Sent By cthroop Date 2023-05-02 Time 15:48 Rev Time 0.00
Received By cthroop Date 2023-05-02 Time 15:18 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2023-03-09 Cont ID  
Sent By cthroop Date 2023-03-09 Time 12:34 Rev Time 0.00
Received By cthroop Date 2023-03-09 Time 10:37 Sent To  
Notes
2023-02-21 13:42:39MECHANICAL DIGITAL SIGNATURE APPROVED ME

Review Stop Z ZONING
Rev No 2 Status P Date 2023-04-17 Cont ID  
Sent By vbroglia Date 2023-04-17 Time 16:05 Rev Time 0.00
Received By vbroglia Date 2023-04-17 Time 16:05 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2023-02-22 Cont ID  
Sent By VBroglia Date 2023-02-22 Time 14:43 Rev Time 0.00
Received By vbroglia Date 2023-02-22 Time 14:43 Sent To  
Notes
***NONE***