Plan Review Details - Permit 23011474
| Plan Review Stops For Permit 23011474 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2023-06-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-06-28 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-06-28 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-05-08 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-05-08 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2023-05-08 09:50:32 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 23011474 | | | ADD: 1920 PALM BEACH LAKES BLVD | | | CONT: UNIVERSAL CONSTRUCTION LLC | | | TEL: 954-586-4261 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: MON. MAY 08TH/2023 | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2) THE ARCHITECT JOHN R. DIEHL CAN BE THE RESIDENT | | | INSPECTOR, BUT HE CANNOT BE THE DESIGNER OF RECORD FOR | | | STRUCTURAL ELEMENTS SINCE THE WHOLE PROJECT IS CONCRETE | | | RESTORATION. WHEN ENGINEERING IS 50 % OR GREATER OF ANY | | | TYPE OF PROJECT, THEN A ENGINEER HAS TO BE THE DESIGNER | | | OF RECORD, IT IS THEN CONSIDERED ENGINEERING. THE | | | ARCHITECT IN THE SCOPE OF WORK NOTE 3 STATES INSTALL | | | AND TIE ANY # 4 OR #5 REBAR AS REQUIRED. THE ARCHITECT | | | IS NOT STATING WHICH SIZE RE-BAR OR SPACING OF REBAR. | | | THE CONTRACTOR CAN NOT TAKE THE RESPONSIBILITY, UNLESS | | | THE CONTRACTOR IS ALSO LICENSED AS AN ENGINEER IN THE | | | STATE OF FLORIDA. | | | ENGINEERS 471.003???QUALIFICATIONS FOR PRACTICE; | | | EXEMPTIONS. ??? | | | (1)???NO PERSON OTHER THAN A DULY LICENSED ENGINEER | | | SHALL PRACTICE ENGINEERING OR USE THE NAME OR TITLE OF | | | ???LICENSED ENGINEER,??? ???PROFESSIONAL ENGINEER,??? | | | OR ANY OTHER TITLE, DESIGNATION, WORDS, LETTERS, | | | ABBREVIATIONS, OR DEVICE TENDING TO INDICATE THAT SUCH | | | PERSON HOLDS AN ACTIVE LICENSE AS AN ENGINEER IN THIS | | | STATE. | | | | | | | | | 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT | | | REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE. | | | | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-04-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-04-04 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-04-04 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2023-04-04 14:16:59 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 23011474 | | | ADD: 1920 PALM BEACH LAKES BLVD | | | CONT: UNIVERSAL CONSTRUCTION LLC | | | TEL: 954-586-4261 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: TUES. APRIL 04TH/2023 | | | ACTION: DENIED | | | | | | 1) 2ND REQUEST. E-MAIL SENT ON 3/31/23 TO: | | | [email protected]. MISSING PACE 16 OF THE | | | RESIDENT INSPECTOR FORMS CONTRACTOR & OWNER SIGNATURES | | | ALL 3 PAGES ARE REQUIRED. | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | 1ST ROUND OF COMMENTS. THE ARCHITECT IS WORKING OUT OF | | | THE SCOPE OF HIS LICENSE, FL. STATUTE 481.2.2.2. TO | | | WORK WITHIN THE LIMITATIONS OF THE 481 LICENSURE YOU | | | WILL NEED TO FILL OUT THE FORMS FOR A RESIDENT | | | INSPECTOR SEE RESIDENT INSPECTOR FORMS PAGES 14-16 NEED | | | TO BE FILED OUT AND RETURNED TO THE BUILDING DEPARTMENT | | | BEFORE PERMIT ISSUANCE CAN OCCUR. | | | | | | RESIDENT INSPECTOR | | | | | | 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER | | | INSPECTIONS SERVICES. THE BUILDING OFFICIAL MAY MAKE, | | | OR CAUSE TO BE MADE BY OTHERS, THE INSPECTIONS REQUIRED | | | BY SECTION 109. HE/SHE MAY ACCEPT REPORTS OF INSPECTORS | | | OF RECOGNIZED INSPECTION SERVICES, PROVIDED THAT AFTER | | | INVESTIGATION HE/SHE IS SATISFIED AS TO THEIR | | | QUALIFICATIONS AND RELIABILITY. A CERTIFICATE CALLED | | | FOR BY ANY PROVISION OF THE TECHNICAL CODES SHALL NOT | | | BE BASED ON SUCH REPORTS UNLESS THE SAME ARE IN WRITING | | | AND CERTIFIED BY A RESPONSIBLE OFFICER OF SUCH SERVICE. | | | THE BUILDING OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY | | | AN INSPECTION SERVICE IN THE FOLLOWING INSTANCES: | | | | | | 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II | | | CONSTRUCTION | | | 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS | | | 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F ???C) IN EXCESS OF 3000 | | | POUNDS PER SQUARE INCH | | | 4. FOR PILE DRIVING | | | 5. FOR BUILDINGS WITH AREA GREATER THAN 20,000 SQUARE | | | FOOT | | | 6. FOR BUILDINGS MORE THAN 2 STORIES IN HEIGHT | | | 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR | | | METHODS OF CONSTRUCTION | | | | | | RESIDENT INSPECTOR FORMS MUST BE SIGNED BY ALL PARTIES | | | NOTARIZED AND RETURNED TO THE BUILDING DEPARTMENT. | | | | | | FOR THE RESIDENT INSPECTOR PLEASE PROVIDE A RESUME' OF | | | INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME' | | | MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED | | | HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL | | | REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, AN | | | INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | CONTACT: CHIEF BUILDING INSPECTOR: RICHARD BRUNELLE AT: | | | 561-805-6670. | | | FORMS SENT TO: [email protected] 3/02/2023 AT | | | 2:18PM. | | | | | | 2) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT | | | REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE. | | | | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-03-02 |
Time |
14:26 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-03-02 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2023-03-02 14:26:40 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | | SERVICES/ BUILDING DIVISION | | | 2020 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 23011474 | | | ADD: 1920 PALM BEACH LAKES BLVD | | | CONT: UNIVERSAL CONSTRUCTION LLC | | | TEL: 954-586-4261 | | | E-MAIL: [email protected] | | | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURS. MARCH 02/2023 | | | ACTION: DENIED | | | | | | 1) THE ARCHITECT IS WORKING OUT OF THE SCOPE OF HIS | | | LICENSE, FL. STATUTE 481.2.2.2. TO WORK WITHIN THE | | | LIMITATIONS OF THE 481 LICENSURE YOU WILL NEED TO FILL | | | OUT THE FORMS FOR A RESIDENT INSPECTOR SEE RESIDENT | | | INSPECTOR FORMS PAGES 14-16 NEED TO BE FILED OUT AND | | | RETURNED TO THE BUILDING DEPARTMENT BEFORE PERMIT | | | ISSUANCE CAN OCCUR. | | | | | | RESIDENT INSPECTOR | | | | | | 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 110.3.9 OTHER | | | INSPECTIONS SERVICES. THE BUILDING OFFICIAL MAY MAKE, | | | OR CAUSE TO BE MADE BY OTHERS, THE INSPECTIONS REQUIRED | | | BY SECTION 109. HE/SHE MAY ACCEPT REPORTS OF INSPECTORS | | | OF RECOGNIZED INSPECTION SERVICES, PROVIDED THAT AFTER | | | INVESTIGATION HE/SHE IS SATISFIED AS TO THEIR | | | QUALIFICATIONS AND RELIABILITY. A CERTIFICATE CALLED | | | FOR BY ANY PROVISION OF THE TECHNICAL CODES SHALL NOT | | | BE BASED ON SUCH REPORTS UNLESS THE SAME ARE IN WRITING | | | AND CERTIFIED BY A RESPONSIBLE OFFICER OF SUCH SERVICE. | | | THE BUILDING OFFICIAL MAY REQUIRE THE OWNER TO EMPLOY | | | AN INSPECTION SERVICE IN THE FOLLOWING INSTANCES: | | | | | | 1. FOR BUILDINGS OR ADDITIONS OF TYPE I OR II | | | CONSTRUCTION | | | 2. FOR ALL MAJOR STRUCTURAL ALTERATIONS | | | 3. WHERE THE CONCRETE DESIGN IS BASED ON COMPRESSIVE | | | STRENGTH (F ???C) IN EXCESS OF 3000 | | | POUNDS PER SQUARE INCH | | | 4. FOR PILE DRIVING | | | 5. FOR BUILDINGS WITH AREA GREATER THAN 20,000 SQUARE | | | FOOT | | | 6. FOR BUILDINGS MORE THAN 2 STORIES IN HEIGHT | | | 7. FOR BUILDINGS AND STRUCTURES OF UNUSUAL DESIGN OR | | | METHODS OF CONSTRUCTION | | | | | | RESIDENT INSPECTOR FORMS MUST BE SIGNED BY ALL PARTIES | | | NOTARIZED AND RETURNED TO THE BUILDING DEPARTMENT. | | | | | | FOR THE RESIDENT INSPECTOR PLEASE PROVIDE A RESUME' OF | | | INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE RESUME' | | | MUST BE ACCOMPANIED BY ALL CERTIFICATES AS SPECIFIED | | | HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE WILL | | | REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, AN | | | INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | CONTACT: CHIEF BUILDING INSPECTOR: RICHARD BRUNELLE AT: | | | 561-805-6670. | | | FORMS SENT TO: [email protected] 3/02/2023 AT | | | 2:18PM. | | | | | | 2) ARCHITECTURE VERSES ENGINEERING. THERE IS NO | | | ARCHITECTURAL PLANS SUBMITTED. THE PHOTOS SHOW THE | | | PLACEMENT OF REINFORCING RE-BARS. A STRUCTURAL ENGINEER | | | WILL NEED TO DEVELOP PLANS AND DETAILS AS TO THE SIZE | | | OF REBAR, PLACEMENT OF REBAR, DOWELING, HOOPS AND OR | | | STIRRUPS INTO EXISTING CONCRETE COLUMNS, BEAMS AND | | | CANTILEVERED ELEVATED FLOOR SLABS, THIS DESIGN WORK | | | MUST BE COMPLETED BY A FLORIDA REGISTERED ENGINEER | | | UNDER FL. STATUTE 471. | | | | | | 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | | REVIEW CYCLE. | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | | REVIEW, SUBSEQUENT | | | REMARKS MAYBE MADE IN THE NEXT REVIEW CYCLE. | | | | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | | PART-TIME/ SEMI-RETIRED. | | | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | | BACK INTO THE OFFICE CALL | | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | | THANK YOU. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-02-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
jcclark |
Date |
2023-02-07 |
Time |
14:34 |
Sent To |
|
|
| Notes |
| 2023-02-07 14:48:48 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | | INSPECTIONS AND APPROVAL. EMERGENCY EXITS SHALL BE | | | MAINTAINED THROUGHOUT CONSTRUCTION. | | | JOSEPH CLARK | | | OFFICE OF THE FIRE MARSHAL | | | 561-804-4748 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-06-28 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
amcgrego |
Date |
2023-06-27 |
Time |
08:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-05-08 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-04-21 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-04-04 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-04-03 |
Time |
16:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-03-02 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-02-06 |
Time |
08:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2023-06-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-06-28 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-06-28 |
Time |
10:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2023-05-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-05-08 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-05-08 |
Time |
09:50 |
Sent To |
|
|
| Notes |
| 2023-05-08 09:51:21 | ENGINEERS 471.003???QUALIFICATIONS FOR PRACTICE; | | | EXEMPTIONS. ??? | | | (1)???NO PERSON OTHER THAN A DULY LICENSED ENGINEER | | | SHALL PRACTICE ENGINEERING OR USE THE NAME OR TITLE OF | | | ???LICENSED ENGINEER,??? ???PROFESSIONAL ENGINEER,??? | | | OR ANY OTHER TITLE, DESIGNATION, WORDS, LETTERS, | | | ABBREVIATIONS, OR DEVICE TENDING TO INDICATE THAT SUCH | | | PERSON HOLDS AN ACTIVE LICENSE AS AN ENGINEER IN THIS | | | STATE. | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2023-04-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-04-04 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-04-04 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2023-04-04 14:19:27 | CURRENTLY THERE ARE NO PAGES ONLY PHOTOGRAPHS, | | | ARCHITECTS AND OR ENGINEERS WILL REQUIRE DIGITAL | | | SIGNATURES FOR ALL PLANS. | | | JAMES A. WITMER BN, PX, SFP, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6717 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2023-03-02 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2023-03-02 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2023-03-02 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2023-03-02 14:30:14 | FOR THE FUTURE PLANS DEVELOPED BY A REGISTERED FLORIDA | | | ENGINEER. THE PLANS WILL NEED TO BE SIGNED DIGITALLY IN | | | ACCORDANCE WITH THE: | | | | | | FL. ADMINISTRATIVE CODE 61G15-23.004 PROCEDURES FOR | | | SIGNING AND SEALING ELECTRONICALLY TRANSMITTED PLANS | | | (DIGITAL SIGNATURES), SPECIFICATIONS, REPORTS OR OTHER | | | DOCUMENTS, REQUIRE 3RD PARTY VERIFICATION. | | | 1) ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR OTHER | | | DOCUMENTS WHICH MUST BE SIGNED, DATED AND SEALED IN | | | ACCORDANCE WITH THE PROVISIONS OF SECTION 471.025, | | | F.S., AND RULE 61G15-23.001, F.A.C., MAY BE SIGNED | | | DIGITALLY AS PROVIDED HEREIN BY THE PROFESSIONAL | | | ENGINEER IN RESPONSIBLE CHARGE. AS USED HEREIN, THE | | | TERMS ???CERTIFICATION AUTHORITY,??? AND ???DIGITAL | | | SIGNATURE??? SHALL HAVE THE MEANINGS ASCRIBED TO THEM | | | IN SECTIONS 668.003(2) AND (3), F.S. | | | (2) A PROFESSIONAL ENGINEER UTILIZING A DIGITAL | | | SIGNATURE TO ELECTRONICALLY SIGN AND SEAL ENGINEERING | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS SHALL | | | HAVE THEIR IDENTITY AUTHENTICATED BY A CERTIFICATION | | | AUTHORITY AND SHALL ASSURE THAT THE DIGITAL SIGNATURE | | | IS: | | | (A) UNIQUE TO THE PERSON USING IT; | | | (B) CAPABLE OF VERIFICATION; | | | (C) UNDER THE SOLE CONTROL OF THE PERSON USING IT; AND, | | | (D) LINKED TO A DOCUMENT IN SUCH A MANNER THAT THE | | | DIGITAL SIGNATURE AND CORRESPONDINGLY THE DOCUMENT IS | | | INVALIDATED IF ANY DATA IN THE DOCUMENT IS CHANGED. | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2023-02-13 |
|
|
Cont ID |
|
| Sent By |
vbroglia |
Date |
2023-02-13 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
vbroglia |
Date |
2023-02-13 |
Time |
13:06 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy