Plan Review Details - Permit 23011348
Plan Review Stops For Permit 23011348
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2023-03-08 Cont ID  
Sent By jgomez Date 2023-03-08 Time 10:45 Rev Time 0.00
Received By jgomez Date 2023-03-08 Time 08:54 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-03-02 Cont ID  
Sent By jgomez Date 2023-03-02 Time 18:57 Rev Time 0.00
Received By jgomez Date 2023-03-02 Time 18:21 Sent To  
Notes
2023-03-02 18:57:40RESIDENTIAL (R2)BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #23011348
 2000 PRESIDENTIAL WAY 2005
  
 NOTE:
 LEVEL 1 ALTERATION. SEC. 602 FBC-EXISTING BUILDING.
 SEC. 702.6 FBC-EXISTING BUILDING. ALL NEW WORK SHALL
 COMPLY WITH THE MATERIALS AND METHODS REQUIREMENTS IN
 THE FLORIDA BUILDING CODE.
  
 1- PROVIDE SITE SPECIFIC SIGNED AND SEALED WIND LOAD
 CALCULATIONS FOR SLIDING GLASS DOORS. SEC. 107.2.1.2
 CITY AMENDMENTS AND SEC. 1609.1 FBC-BUILDING.
  
 2- FBC-B 1405.4, A FLASHING DETAIL OR SPECIFICATION IS
 REQUIRED. THIS COMMENT CAN BE RESOLVED BY DOING ONE OF
 THE FOLLOWING:
 REVISE THE FLOOR PLAN TO NOTE THAT FLASHING IS REQUIRED
 AND NOTE THE CODE REFERENCE - EXAMPLE "FLASHING IN
 ACCORDANCE WITH FBC R 703.4/B 1405.4 WILL BE
 INSTALLED".
  
 PROVIDE A WRITTEN SPECIFICATION IN LETTER FORM - THIS
 MAY INCLUDE MORE THAN ONE OPTION
  
 PROVIDE A FLASHING DETAIL - THIS MAY INCLUDE MORE THAN
 ONE OPTION
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-03-08 Cont ID  
Sent By jgomez Date 2023-03-08 Time 13:19 Rev Time 0.00
Received By jgomez Date 2023-03-08 Time 13:18 Sent To I
Notes
2023-03-08 13:18:52RECEIVED SIGNED AND SEALED ENGINEERING. JG.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-08 Cont ID  
Sent By jgomez Date 2023-03-08 Time 11:21 Rev Time 0.00
Received By jgomez Date 2023-03-03 Time 15:58 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-03-02 Cont ID  
Sent By jgomez Date 2023-03-02 Time 18:58 Rev Time 0.00
Received By jgomez Date 2023-01-27 Time 16:56 Sent To I
Notes
***NONE***

Review Stop L-CODE2 CODE ENFORCEMENT INSPECTION
Rev No 1 Status N Date 2023-03-08 Cont ID  
Sent By jgomez Date 2023-03-08 Time 13:17 Rev Time 0.00
Received By jgomez Date 2023-03-08 Time 13:15 Sent To  
Notes
2023-03-08 13:16:37REVIEW STOP ENTERED BY MISTAKE. JG

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-03-08 Cont ID  
Sent By jgomez Date 2023-03-08 Time 13:19 Rev Time 0.00
Received By jgomez Date 2023-03-08 Time 13:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2023-03-08 Cont ID  
Sent By jgomez Date 2023-03-08 Time 10:40 Rev Time 0.00
Received By jgomez Date 2023-03-08 Time 10:38 Sent To  
Notes
2023-03-08 10:44:16SIGNATURE REVIEW
  
 1- WIND LOAD CALCULATIONS SUBMITTED HAVE A COPY OF THE
 ENGINEER???S DIGITAL SIGNATURE. DIGITAL SIGNATURES ARE
 NOT ALLOWED TO BE PRINTED. ALL DOCUMENTS PREPARED BY A
 LICENSED ENGINEER NEED TO HAVE THE ORIGINAL VERIFIABLE
 DIGITAL SIGNATURE OF THE ENGINEER OF RECORD AS REQUIRED
 BY SEC. 61G15-23.004 FAC AND CHAPTER 471 F.S.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  