Plan Review Details - Permit 23011342
| Plan Review Stops For Permit 23011342 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-04-08 |
|
|
Cont ID |
|
| Sent By |
eroseber |
Date |
2023-04-08 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
eroseber |
Date |
2023-04-08 |
Time |
17:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-03-17 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-03-17 |
Time |
12:42 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-03-17 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2023-03-17 12:57:26 | PETER E VALENTI | | | BUILDING PLANS EXAMINER II/INSPECTOR | | | [email protected] | | | 561 805 6673 | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC M = FBC MECHANICAL | | | FBC FG = FBC FUEL GAS | | | | | | 2ND BUILDING REVIEW DENIED: | | | | | | FBC R 310.2.1, THE AREA FOR WINDOW OPENING #11 (WIDTH) | | | DOES NOT MEET THE MINIMUM REQUITREMENTS OF 20" AS THIS | | | OPENING IS FOR A BEDROOM (EGRESS). PLEASE RESUBMIT WITH | | | A WINDOW (CLEAR OPENING) THAT MEETS THE FOLLOWING | | | MINIMUM OPENING REQUIREMENTS: | | | | | | MINIMUM NET CLEAR OPENING: 5.7 S.F. | | | MINIMUM NET CLEAR HEIGHT: 24" | | | MINIMUM NET CLEAR WIDTH: 20" |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-02-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-02-21 |
Time |
20:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2023-02-21 |
Time |
20:33 |
Sent To |
|
|
| Notes |
| 2023-02-21 20:35:01 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC R = FBC RESIDENTIAL | | | | | | 1. FBC R 703.4, FBC B 1405.4, A FLASHING DETAIL OR | | | SPECIFICATION IS REQUIRED. THIS COMMENT CAN BE RESOLVED | | | BY DOING ONE OF THE FOLLOWING: | | | | | | REVISE THE FLOOR PLAN TO NOTE THAT FLASHING IS | | | REQUIRED AND NOTE THE CODE REFERENCE - EXAMPLE | | | "FLASHING IN ACCORDANCE WITH FBC R 703.4/B 1405.4 WILL | | | BE INSTALLED". | | | PROVIDE A WRITTEN SPECIFICATION IN LETTER FORM - THIS | | | MAY INCLUDE MORE THAN ONE OPTION | | | PROVIDE A FLASHING DETAIL - THIS MAY INCLUDE MORE THAN | | | ONE OPTION | | | | | | 2. . FBC EB 702.5, REVISE PLAN TO SHOW TYPE OF WINDOWS | | | THAT ARE EXISTING, TYPE OF WINDOW PROPOSED FOR EACH | | | BEDROOM WINDOW OPENING. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
P |
Date |
2023-04-08 |
|
|
Cont ID |
|
| Sent By |
eroseber |
Date |
2023-04-08 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
eroseber |
Date |
2023-03-29 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-03-17 |
|
|
Cont ID |
|
| Sent By |
pvalenti |
Date |
2023-03-17 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
pvalenti |
Date |
2023-03-01 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-02-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2023-02-21 |
Time |
20:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2023-01-27 |
Time |
12:50 |
Sent To |
|
|
| Notes |
|
|
|