Plan Review Details - Permit 23011342
Plan Review Stops For Permit 23011342
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-04-08 Cont ID  
Sent By eroseber Date 2023-04-08 Time 17:23 Rev Time 0.00
Received By eroseber Date 2023-04-08 Time 17:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2023-03-17 Cont ID  
Sent By pvalenti Date 2023-03-17 Time 12:42 Rev Time 0.00
Received By pvalenti Date 2023-03-17 Time 10:45 Sent To  
Notes
2023-03-17 12:57:26PETER E VALENTI
 BUILDING PLANS EXAMINER II/INSPECTOR
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 2ND BUILDING REVIEW DENIED:
  
 FBC R 310.2.1, THE AREA FOR WINDOW OPENING #11 (WIDTH)
 DOES NOT MEET THE MINIMUM REQUITREMENTS OF 20" AS THIS
 OPENING IS FOR A BEDROOM (EGRESS). PLEASE RESUBMIT WITH
 A WINDOW (CLEAR OPENING) THAT MEETS THE FOLLOWING
 MINIMUM OPENING REQUIREMENTS:
  
 MINIMUM NET CLEAR OPENING: 5.7 S.F.
 MINIMUM NET CLEAR HEIGHT: 24"
 MINIMUM NET CLEAR WIDTH: 20"

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2023-02-21 Cont ID  
Sent By shill Date 2023-02-21 Time 20:33 Rev Time 0.00
Received By shill Date 2023-02-21 Time 20:33 Sent To  
Notes
2023-02-21 20:35:01****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC R = FBC RESIDENTIAL
  
 1. FBC R 703.4, FBC B 1405.4, A FLASHING DETAIL OR
 SPECIFICATION IS REQUIRED. THIS COMMENT CAN BE RESOLVED
 BY DOING ONE OF THE FOLLOWING:
  
  REVISE THE FLOOR PLAN TO NOTE THAT FLASHING IS
 REQUIRED AND NOTE THE CODE REFERENCE - EXAMPLE
 "FLASHING IN ACCORDANCE WITH FBC R 703.4/B 1405.4 WILL
 BE INSTALLED".
  PROVIDE A WRITTEN SPECIFICATION IN LETTER FORM - THIS
 MAY INCLUDE MORE THAN ONE OPTION
  PROVIDE A FLASHING DETAIL - THIS MAY INCLUDE MORE THAN
 ONE OPTION
  
 2. . FBC EB 702.5, REVISE PLAN TO SHOW TYPE OF WINDOWS
 THAT ARE EXISTING, TYPE OF WINDOW PROPOSED FOR EACH
 BEDROOM WINDOW OPENING.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status P Date 2023-04-08 Cont ID  
Sent By eroseber Date 2023-04-08 Time 17:23 Rev Time 0.00
Received By eroseber Date 2023-03-29 Time 12:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-03-17 Cont ID  
Sent By pvalenti Date 2023-03-17 Time 12:57 Rev Time 0.00
Received By pvalenti Date 2023-03-01 Time 15:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2023-02-21 Cont ID  
Sent By shill Date 2023-02-21 Time 20:35 Rev Time 0.00
Received By shill Date 2023-01-27 Time 12:50 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved