Plan Review Details - Permit 23011340
| Plan Review Stops For Permit 23011340 |
| Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2023-03-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-03-10 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2023-03-10 15:42:36 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23011340 | | | | | | REVIEWED: MARCH 10, 2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENT: | | | | | | ASBESTOS REVIEW: | | | | | | FAILED PLAN REVIEW: | | | | | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | | -RENOVATION.HTML | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-03-10 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-03-10 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-03-10 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2023-03-10 15:50:18 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23011340 | | | | | | REVIEWED: MARCH 10, 2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENTS: | | | | | | AS PER SECTION 107.2.1 | | | PORVIDE ACCURATE DOCUMENTATION RELATED TO SCOPE OF | | | WORK: EXISTING, DEMO AND PROPOSED FHA BATHS LAYOUT. | | | PROVIDE BETTER LOCATION FOR HC SEATING AT BAR AND SHOW | | | ACCURATE SECTION FOR HC BAR HEIGHT. | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2023-03-02 |
|
|
Cont ID |
|
| Sent By |
mpeterso |
Date |
2023-03-02 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
mpeterso |
Date |
2023-03-02 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2023-03-02 14:38:06 | ELECTRIC REVIEW FAILED | | | | | | 1) ELECTRIC RISER DIAGRAM DOES NOT INCLUDE ALL | | | EQUIPMENT. PLAN INDICATES A NEW PANEL B AND EXISTING | | | PANEL A AND NO PANELS LABELED AS D. PLEASE DETAIL ON | | | ELECTRIC RISER DIAGRAM ALL EQUIPMENT, CONDUIT, | | | CONDUCTORS, OVERCURRENT PROTECTION AND GROUNDING | | | ELECTRODE SYSTEM AS REQUIRED PER NEC 215.5 | | | | | | NEC 215.5 DIAGRAMS OF FEEDERS. IF REQUIRED BY THE | | | AUTHORITY HAVING JURISDICTION, A DIAGRAM SHOWING FEEDER | | | DETAILS SHALL BE PROVIDED PRIOR TO THE INSTALLATION OF | | | THE FEEDERS. | | | | | | 2) PANEL SCHEDULES DETAIL ALL AIR CONDITIONING | | | EQUIPMENT AS FUTURE, HOWEVER, CIRCUIT WIRING IS | | | INDICATED ON FLOOR PLAN. IF HVAC EQUIPMENT IS TO BE | | | INSTALLED PLEASE INDICATE EQUIPMENT ON FLOOR PLANS AND | | | PROVIDE SPECIFICATIONS. FBC 107.2 | | | | | | FBC 107.2, CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL | | | | | | 3) PANEL SCHEDULES INDICATE A WATER HEATER, HOWEVER, | | | NONE IS DETAILED ON FLOOR PLAN. PLEASE PROVIDE DETAILS | | | ON FLOOR PLAN AND PROVIDE SPECIFICATIONS. FBC 107.2 | | | | | | 4) PLEASE PROVIDE A LETTER FROM FPL DETAILING AVAILABLE | | | FAULT CURRENT AS INDICATED ON ELECTRICAL PLANS. FBC | | | 107.2 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. | | | | | | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE 2020 7TH ED. | | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | | 7TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | | 7TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | V/R, | | | | | | MICHAEL PETERSON | | | ELECTRICAL PLANS EXAMINER | | | [email protected] | | | 561-805-6746 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2023-02-01 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2023-02-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2023-01-31 |
Time |
15:09 |
Sent To |
|
|
| Notes |
| 2023-02-01 10:42:01 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) SHEET A 1.0 - THERE IS AN INDICATION OF AN OCCUPANCY | | | LOAD CALCULATION OF 2084 SQ FT @ 60 SQ FT PER PERSON, | | | HOWEVER, THE FLOOR PLAN DOES NOT DELINEATE TO 2084 SQ | | | FT. | | | | | | PER NFPA 101 CH 7 MEANS OF EGRESS | | | | | | 7.3.1.2* OCCUPANT LOAD FACTOR. THE OCCUPANT LOAD IN ANY | | | BUILDING | | | OR PORTION THEREOF SHALL BE NOT LESS THAN THE NUMBER OF | | | PERSONS DETERMINED | | | BY DIVIDING THE FLOOR AREA ASSIGNED TO THAT USE BY THE | | | OCCUPANT | | | LOAD FACTOR FOR THAT USE AS SPECIFIED IN TABLE 7.3.1.2, | | | FIGURE 7.3.1.2(A), | | | AND FIGURE 7.3.1.2(B). WHERE BOTH GROSS AND NET AREA | | | FIGURES ARE GIVEN | | | FOR THE SAME OCCUPANCY, CALCULATIONS SHALL BE MADE BY | | | APPLYING THE | | | GROSS AREA FIGURE TO THE GROSS AREA OF THE PORTION OF | | | THE BUILDING DEVOTED | | | TO THE USE FOR WHICH THE GROSS AREA FIGURE IS SPECIFIED | | | AND BY APPLYING | | | THE NET AREA FIGURE TO THE NET AREA OF THE PORTION OF | | | THE BUILDING DEVOTED | | | TO THE USE FOR WHICH THE NET AREA FIGURE IS SPECIFIED | | | | | | PLEASE REVIEW AND BETTER DEFINE THE AREA OF 2084 IN | | | RELATIONS TO ALL OTHER AREAS THAT WOULD MEET THE | | | REQUIRMENTS AND 58 PEOPLE AS PROPSED. | | | | | | | | | | | | 2) SHEET A 1.0 - THERE ARE NO INDICATIONS OF EXIT DOOR | | | HARDWARE NOR A DOOR SCHEDULE THAT INDICATES COMPLIANCE | | | WITH NFPA 101, INCLUDING LOCKS & LATCHES. | | | | | | 7.2.1.5.10* A LATCH OR OTHER FASTENING DEVICE ON A DOOR | | | LEAF SHALL BE | | | PROVIDED WITH A RELEASING DEVICE THAT HAS AN OBVIOUS | | | METHOD OF OPERATION | | | AND THAT IS READILY OPERATED UNDER ALL LIGHTING | | | CONDITIONS. | | | 7.2.1.5.10.1 THE RELEASING MECHANISM FOR ANY LATCH | | | SHALL BE LOCATED AS | | | FOLLOWS: | | | (1) NOT LESS THAN 34 IN. (865 MM) ABOVE THE FINISHED | | | FLOOR FOR OTHER | | | THAN EXISTING INSTALLATIONS | | | (2) NOT MORE THAN 48 IN. (1220 MM) ABOVE THE FINISHED | | | FLOOR | | | 7.2.1.5.10.2 THE RELEASING MECHANISM SHALL OPEN THE | | | DOOR LEAF WITH NOT | | | MORE THAN ONE RELEASING OPERATION, UNLESS OTHERWISE | | | SPECIFIED IN | | | 7.2.1.5.10.3, 7.2.1.5.10.4, 7.2.1.5.10.6, OR | | | 7.2.1.5.10.7 | | | | | | | | | 7.2.1.5 LOCKS, LATCHES, AND ALARM DEVICES | | | 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED | | | READILY FROM THE | | | EGRESS SIDE WHENEVER THE BUILDING IS OCCUPIED | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | | OF A KEY, A TOOL, | | | OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM THE | | | EGRESS SIDE | | | | | | PLEASE REVIEW AND PROVIDE DETAILS MEETING THE | | | REQUIREMENTS. | | | | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-03-10 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-03-10 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-01-30 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2023-03-10 |
|
|
Cont ID |
|
| Sent By |
lbond |
Date |
2023-03-10 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
lbond |
Date |
2023-03-10 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2023-03-10 15:59:40 | BUILDING REVIEW COMMENTS: | | | | | | W.P.B. PERMIT: 23011340 | | | | | | REVIEWED: MARCH 10, 2023 | | | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | | BELOW) | | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | | BUILDING-PERMIT-FORMS | | | FBC BUILDING | | | FBC EXISTING BUILDING | | | | | | COMMENTS: | | | | | | 109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC | | | IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON | | | NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR | | | WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE | | | WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY | | | UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO | | | YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE | | | QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE | | | R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU | | | ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE | | | UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] | | | | | | | | | | | | IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE DO NOT | | | HESITATE TO CONTACT ME | | | | | | LOUIS BOND, AIA | | | BUILDING PLANS EXAMINER II | | | DEVELOPMENT SERVICES DEPT. | | | BUILDING DIVISION | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FLORIDA 33401 | | | PH: 561-805-6729 | | | FX: 561-805-6676 | | | EMAIL: [email protected] | | | | | | | | | NOTES: | | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | | EACH COMMENT IS BEING ADDRESSED. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-07 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-07 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2023-02-07 16:08:37 | 1ST REVIEW FMC | | | PERMIT: 23011340 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET 1.0A OF 8: THIS APPEARS TO BE A CHANGE OF USE | | | FROM WAREHOUSE TO AN A-2. PLEASE PROVIDE A COMPLETE | | | MECHANICAL DESIGN FOR THIS CHANGE OF USE. I CAN FIND NO | | | PERMITS FOR A MECHANICAL SYSTEM AT THIS ADDRESS EVERY | | | BEING PERMITTED. FEC M1401.3 AND FMC 312.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2023-01-31 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-31 |
Time |
06:12 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-01-31 |
Time |
06:05 |
Sent To |
|
|
| Notes |
| 2023-01-31 06:20:01 | 1ST PLUMBING REVIEW | | | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | | | 1. 2020 FPC 607.1.1 - HOT WATER DELIVERY - PER THIS | | | SECTION, THE THERMOSTAT ON THE WATER HEATER CANNOT | | | SERVE AS THE LIMITING DEVICE FOR HOT OR TEMPERED WATER | | | DELIVERY. A MIXING DEVICE MUST LIMIT THE TEMPERATURE. | | | THE DEVICE MUST COMPLY WITH ASSE 1017 AND MUST BE | | | INSTALLED AT THE HOT WATER SOURCE PER 2020 FPC 613.1. | | | THIS IS IN ADDITION TO THE REQUIREMENTS FOR PUBLIC | | | HANDWASHING PROTECTION FOR TEMPERED WATER. | | | | | | 2. THIS DRAWING APPEARS TO BE INACCURATE. I HAVE | | | VISITED THIS SITE AND HAVE 1ST HAND KNOWLEDGE OF THE | | | BATHROOMS. THE "EXISTING" BATHROOMS DO NOT MEET ADA | | | MEASUREMENTS AND THEY ARE DRAWN AS IF THEY DO. PLEASE | | | SUBMIT A TRUE TO LIFE DRAWING OF THE "EXISTING" AND | | | SHOW DETAILS OF THE REPAIRS TO MAKE THIS "AFTER THE | | | FACT" PERMIT MEET THE REQUIREMENTS OF 2020 FPC 404.1 | | | AND 2020 FPC 403.1.1. LABEL THE BATHROOMS FOR USE BY | | | EACH SEX PER 403.2 OR INDICATE UNISEX BATHROOMS. | | | | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | | | | RYAN W. BROWN | | | CHIEF PLUMBING INSPECTOR | | | OFFICE: 561-805-6692 | | | CELL: 561-517-4293 | | | EMAIL: [email protected] | | | | | | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | | V7 FGC - 2020 FLORIDA FUEL GAS | | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | 2021 F.S. - 2021 FLORIDA STATUTES | | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | | FBC CHAPTER 1 | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-02-07 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-02-07 |
Time |
16:17 |
Sent To |
|
|
| Notes |
|
|
|