| 2023-02-02 09:19:12 | JONATHAN BROOKS JR. |
| | BUILDING PLANS EXAMINER |
| | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| | PHONE (561) 805-6656 |
| | EMAIL: [email protected] |
| | |
| | 1ST REVIEW: FBC 2020 7TH EDITION |
| | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| | FBC B = FBC BUILDING |
| | FBC R = FBC RESIDENTIAL |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| | |
| | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT |
| | APPROVAL FL25621.05-R2 REQUIRES MULTIPLE INSTALLATION |
| | METHODS FOR STRUCTURES LOCATED IN EXPOSURE B, C, OR D |
| | HAVE EITHER FLAT ROOF OR GABLE/HIP ROOF WITH MAX SLOPE |
| | OF 12:12 WITH A MEAN ROOF HEIGHT 30 FEET OR LESS WIND |
| | SPEED 170 MPH. PLEASE INDICATE (HIGHLIGHT/CIRCLE) |
| | METHODS USED FOR EACH ZONE ON PAGE #3 OF THE EVALUATION |
| | REPORT. THIS PROJECT IS LOCATED IN AN EXPOSURE CATEGORY |
| | D AREA. |
| | 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT |
| | APPROVAL FL16709-R10 SELECTED OPTION FOR SYSTEM NO W-4; |
| | EXPOSURE (C); ENCLOSURE (ENCLOSED); ROOF HEIGHT (15 < H |
| | < 20); ULTIMATE WIND SPEED (170), IS NOT CORRECT. THE |
| | CORRECT EXPOSURE FOR THE LISTED ADDRESS IS EXPOSURE D. |
| | PRODUCT APPROVAL FL16709-R10 WILL NOT SATISFY EXPOSURE |
| | CATEGORY D ENCLOSED AREAS WITHOUT USING INSULATION. |
| | 3. SUBMITTED PRODUCT APPROVAL FL9777-R16 HAS BEEN |
| | REVISED TO FL9777-R17. PLEASE PROVIDE A COMPLETE SET; |
| | IT COVERS MULTIPLE PRODUCTS & LIMITS OF USE. SELECT |
| | PRODUCT DESCRIPTION AND LIMITS OF USE. ALL APPLICABLE |
| | DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON |
| | THE PRODUCT APPROVAL DRAWINGS. |
| | 4. SUBMITTED PRODUCT APPROVAL FL12328-R9 HAS BEEN |
| | REVISED TO FL1228-R10. PLEASE PROVIDE A COMPLETE SET; |
| | IT COVERS MULTIPLE PRODUCTS & LIMITS OF USE. SELECT |
| | PRODUCT DESCRIPTION AND LIMITS OF USE. ALL APPLICABLE |
| | DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON |
| | THE PRODUCT APPROVAL DRAWINGS. |
| | 5. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL2569-R22 |
| | SELECTED PRODUCT TYPE; LASTOBOND PRO HT-S UNDERLAYMENT |
| | IS APPROVED FOR USE AS JOINT STRIPS IN WOOD SHAKES OR |
| | WOOD SHINGLES INSTALLATION ONLY. |
| | 6. FBC B 107.2.1 FOR CLARITY PLEASE PROVIDE A ROOF |
| | DIAGRAM/SKETCH WITH THE AREAS TO RECEIVE NEW ROOFING |
| | CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF SLOPE(S), |
| | MEAN ROOF HEIGHT(S). FLAT/LOW SLOPE ROOFS MUST SHOW |
| | POSITIVE DRAINAGE. |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | |