| Plan Review Stops For Permit 23011134 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-04 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-04 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2023-04-25 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-04-25 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-04-25 |
Time |
13:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2023-04-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-04-12 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-04-12 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2023-04-12 14:13:54 | SFR REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) FOR THE ROOM CHANGED FROM GARAGE TO LIVING SPACE - | | | THE MINIMUM CEILING R VALUE NEEDS TO BE R 30 - PER FBC | | | ENERGY TABLE R402.1.2 AND THE ENERGY CALCULATIONS | | | PROVIDED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2023-02-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-22 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-22 |
Time |
11:13 |
Sent To |
|
|
| Notes |
| 2023-02-22 13:03:56 | SFR REMODEL | | | REVIEWED BY ROGER MCPHERSON | | | 561-805-6716 | | | [email protected] | | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | | AMENDMENT | | | | | | CORRECTIONS NEEDED - | | | | | | 1) FOR THE EXISTING GARAGE THE DRAWINGS SAY TO RAISE | | | THE FLOOR - PLEASE PROVIDE THE DETAILS TO RAISE THE | | | FLOOR - FBC WPB 701.2.1 | | | | | | 2) PLEASE PROVIDE DETAILS FOR THE ATTACHMENT OF THE | | | GARAGE DOOR TO THE EXTERIOR WALL - FBC R703.1.2 | | | | | | 3) FOR THE GARAGE DOOR WALL FILL IN - PLEASE SHOW THAT | | | A WATER RESISTIVE BARRIER IS REQUIRED - R703.1.1 WATER | | | RESISTANCE. | | | THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED AND | | | CONSTRUCTED IN A MANNER THAT PREVENTS THE ACCUMULATION | | | OF WATER WITHIN THE WALL ASSEMBLY BY PROVIDING A | | | WATER-RESISTANT BARRIER BEHIND THE EXTERIOR CLADDING AS | | | REQUIRED BY SECTION R703.2 AND A MEANS OF DRAINING TO | | | THE EXTERIOR WATER THAT PENETRATES THE EXTERIOR | | | CLADDING. R703.2 WATER-RESISTIVE BARRIER. | | | ONE LAYER OF NO. 15 ASPHALT FELT, FREE FROM HOLES AND | | | BREAKS, COMPLYING WITH ASTM D226 FOR TYPE 1 FELT OR | | | OTHER APPROVED WATER-RESISTIVE BARRIER SHALL BE APPLIED | | | OVER STUDS OR SHEATHING OF ALL EXTERIOR WALLS. NO. 15 | | | ASPHALT FELT SHALL BE APPLIED HORIZONTALLY, WITH THE | | | UPPER LAYER LAPPED OVER THE LOWER LAYER NOT LESS THAN 2 | | | INCHES (51 MM). | | | | | | 4) FROM GARAGE TO LIVING SPACE - PLEASE SHOW THE | | | MINIMUM WALL AND CEILING INSULATION TYPE AND "R" VALUE | | | PER FBC ENERGY TABLE R402.1.2 OR MATCH THE ENERGY | | | CALCULATIONS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-02-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2023-02-06 |
Time |
07:07 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2023-02-06 |
Time |
07:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2023-05-01 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2023-05-01 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2023-05-01 |
Time |
12:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-02-07 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-02-07 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-04 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-04 |
Time |
08:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2023-05-02 |
|
|
Cont ID |
|
| Sent By |
aoliver |
Date |
2023-05-02 |
Time |
19:07 |
Rev Time |
0.00 |
| Received By |
aoliver |
Date |
2023-04-11 |
Time |
08:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2023-02-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-22 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-01-25 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2023-05-12 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2023-05-12 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2023-05-08 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2023-05-12 11:07:09 | NO FEES DUE PER IMPACT. LEM | | 2023-05-08 07:16:31 | 5/8/23 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2023-02-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-22 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-22 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2023-02-22 13:49:02 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | | [email protected] . | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2023-04-19 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-04-19 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-04-19 |
Time |
11:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2023-01-27 |
|
|
Cont ID |
|
| Sent By |
medwards |
Date |
2023-01-27 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
medwards |
Date |
2023-01-27 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2023-01-27 13:22:05 | 1ST REVIEW FMC | | | PERMIT: 23011134 | | | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | | FMC- FLORIDA MECHANICAL CODE | | | FEC- FLORIDA ENERGY CONSERVATION | | | FGC- FLORIDA FUEL GAS | | | FEX- FLORIDA EXISTING BUILDING CODE | | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | | F.S.- FLORIDA STATUTES | | | FAC- FLORIDA ACCESSIBILITY CODE | | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE A COMPLETE SCOPE OF WORK FOR THE MECHANICAL | | | WORK FOR THIS PROJECT INCLUDING ENERGY CALCULATIONS, | | | MECHANICAL EQUIPMENT SIZING CALCULATIONS AND A | | | MECHANICAL DRAWING. FBC 107.3.5 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM. | | | | | | MICHAEL EDWARDS | | | MECHANICAL EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL. 33401 | | | 561-805-6728 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2023-01-27 |
|
|
Cont ID |
|
| Sent By |
rwbrown |
Date |
2023-01-27 |
Time |
06:26 |
Rev Time |
0.00 |
| Received By |
rwbrown |
Date |
2023-01-27 |
Time |
06:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
P |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-05-04 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-05-04 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
P |
Date |
2023-04-12 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-04-12 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-04-12 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2023-02-22 |
|
|
Cont ID |
|
| Sent By |
rmcphers |
Date |
2023-02-22 |
Time |
13:49 |
Rev Time |
0.00 |
| Received By |
rmcphers |
Date |
2023-02-22 |
Time |
13:49 |
Sent To |
|
|
| Notes |
| 2023-02-06 07:08:42 | ELECTRICAL PAGE SIGNATURE APPROVED JLEAHY |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2023-05-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2023-05-04 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2023-05-04 |
Time |
10:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2023-05-01 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2023-05-01 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2023-05-01 |
Time |
12:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2023-02-07 |
|
|
Cont ID |
|
| Sent By |
amhamilt |
Date |
2023-02-07 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
amhamilt |
Date |
2023-02-07 |
Time |
14:31 |
Sent To |
|
|
| Notes |
| 2023-02-07 14:32:57 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | | | PLEASE VERIFY ON PLANS THAT TWO PARKING SPACES ARE | | | BEING RETAINED *AND* THAT THE LESSER OF 1,000 SF OR 75% | | | OF THE FRONT SETBACK OF GREENSPACE IS BEING RETAINED | | | (PLEASE SHOW CALCULATIONS TO VERIFY THIS) | | | | | | ANNE HAMILTON | | | HISTORIC PRESERVATION PLANNER | | | [email protected] | | | 561.822.1428 | | | |
|
|